Cargando…

Comparison of Visual Outcomes and Quality of Life in Patients with High Myopic Cataract after Implantation of AT LISA Tri 839MP and LS-313 MF30 Intraocular Lenses

PURPOSE: To investigate the benefits of multifocal lens in patients with high myopic cataract and compare the clinical effects between AT LISA tri 839MP and MPlus LS-313 MF30 intraocular lenses (IOLs) in high myopic eyes. METHODS: This retrospective cohort study analyzed 60 eyes with axial length &g...

Descripción completa

Detalles Bibliográficos
Autores principales: Shen, Jiying, Zhang, Limei, Ni, Shuang, Cai, Lei, Guo, Haike, Yang, Jin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8901302/
https://www.ncbi.nlm.nih.gov/pubmed/35265369
http://dx.doi.org/10.1155/2022/5645752
_version_ 1784664334791606272
author Shen, Jiying
Zhang, Limei
Ni, Shuang
Cai, Lei
Guo, Haike
Yang, Jin
author_facet Shen, Jiying
Zhang, Limei
Ni, Shuang
Cai, Lei
Guo, Haike
Yang, Jin
author_sort Shen, Jiying
collection PubMed
description PURPOSE: To investigate the benefits of multifocal lens in patients with high myopic cataract and compare the clinical effects between AT LISA tri 839MP and MPlus LS-313 MF30 intraocular lenses (IOLs) in high myopic eyes. METHODS: This retrospective cohort study analyzed 60 eyes with axial length >26 mm in 40 patients. Thirty eyes were implanted with MF30, and the remaining 30 eyes were implanted with 839MP. Postoperative uncorrected distance visual acuity (UDVA), best corrected distance visual acuity (BCDVA), uncorrected intermediate visual acuity (UIVA) and uncorrected near visual acuity (UNVA), defocus curve, modulation transfer function (MTF) curve, Strehl ratio (SR), and complications were compared between the two groups. RESULTS: All vision outcomes were significantly improved in both groups (p < 0.05). There was no significant between-group difference in UDVA at 1 and 3 months postoperatively (p > 0.05). However, UIVA and UNVA were significantly better in the 839MP group (p < 0.05). The VF-14 score, especially for near vision quality, was significantly higher in the MF30 group (2.2 ± 0.9 vs. 0.8 ± 0.7; p ≤ 0.001). The SR of both groups significantly increased postoperatively (p < 0.05). All the 3-month MTF curve values (MTF 10 total, MTF 10 internal, MTF 30 total, and MTF 30 internal) were significantly better in the 839MP group (p < 0.05). Meanwhile, all the high-order aberration values (coma, spherical aberration, and trefoil) were significantly greater in the MF30 group (p < 0.05). CONCLUSION: Multifocal IOL implantation achieves good quality of distance, intermediate, and near vision in patients with high myopia, improving their quality of life. Both 839MP and MF30 IOLs can provide good distance vision, but 839MP performs better in near and intermediate vision. However, for some patients with an extra-long optic axis, MF30 may be a good choice because of its wider range of degrees.
format Online
Article
Text
id pubmed-8901302
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-89013022022-03-08 Comparison of Visual Outcomes and Quality of Life in Patients with High Myopic Cataract after Implantation of AT LISA Tri 839MP and LS-313 MF30 Intraocular Lenses Shen, Jiying Zhang, Limei Ni, Shuang Cai, Lei Guo, Haike Yang, Jin J Ophthalmol Research Article PURPOSE: To investigate the benefits of multifocal lens in patients with high myopic cataract and compare the clinical effects between AT LISA tri 839MP and MPlus LS-313 MF30 intraocular lenses (IOLs) in high myopic eyes. METHODS: This retrospective cohort study analyzed 60 eyes with axial length >26 mm in 40 patients. Thirty eyes were implanted with MF30, and the remaining 30 eyes were implanted with 839MP. Postoperative uncorrected distance visual acuity (UDVA), best corrected distance visual acuity (BCDVA), uncorrected intermediate visual acuity (UIVA) and uncorrected near visual acuity (UNVA), defocus curve, modulation transfer function (MTF) curve, Strehl ratio (SR), and complications were compared between the two groups. RESULTS: All vision outcomes were significantly improved in both groups (p < 0.05). There was no significant between-group difference in UDVA at 1 and 3 months postoperatively (p > 0.05). However, UIVA and UNVA were significantly better in the 839MP group (p < 0.05). The VF-14 score, especially for near vision quality, was significantly higher in the MF30 group (2.2 ± 0.9 vs. 0.8 ± 0.7; p ≤ 0.001). The SR of both groups significantly increased postoperatively (p < 0.05). All the 3-month MTF curve values (MTF 10 total, MTF 10 internal, MTF 30 total, and MTF 30 internal) were significantly better in the 839MP group (p < 0.05). Meanwhile, all the high-order aberration values (coma, spherical aberration, and trefoil) were significantly greater in the MF30 group (p < 0.05). CONCLUSION: Multifocal IOL implantation achieves good quality of distance, intermediate, and near vision in patients with high myopia, improving their quality of life. Both 839MP and MF30 IOLs can provide good distance vision, but 839MP performs better in near and intermediate vision. However, for some patients with an extra-long optic axis, MF30 may be a good choice because of its wider range of degrees. Hindawi 2022-02-28 /pmc/articles/PMC8901302/ /pubmed/35265369 http://dx.doi.org/10.1155/2022/5645752 Text en Copyright © 2022 Jiying Shen et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Shen, Jiying
Zhang, Limei
Ni, Shuang
Cai, Lei
Guo, Haike
Yang, Jin
Comparison of Visual Outcomes and Quality of Life in Patients with High Myopic Cataract after Implantation of AT LISA Tri 839MP and LS-313 MF30 Intraocular Lenses
title Comparison of Visual Outcomes and Quality of Life in Patients with High Myopic Cataract after Implantation of AT LISA Tri 839MP and LS-313 MF30 Intraocular Lenses
title_full Comparison of Visual Outcomes and Quality of Life in Patients with High Myopic Cataract after Implantation of AT LISA Tri 839MP and LS-313 MF30 Intraocular Lenses
title_fullStr Comparison of Visual Outcomes and Quality of Life in Patients with High Myopic Cataract after Implantation of AT LISA Tri 839MP and LS-313 MF30 Intraocular Lenses
title_full_unstemmed Comparison of Visual Outcomes and Quality of Life in Patients with High Myopic Cataract after Implantation of AT LISA Tri 839MP and LS-313 MF30 Intraocular Lenses
title_short Comparison of Visual Outcomes and Quality of Life in Patients with High Myopic Cataract after Implantation of AT LISA Tri 839MP and LS-313 MF30 Intraocular Lenses
title_sort comparison of visual outcomes and quality of life in patients with high myopic cataract after implantation of at lisa tri 839mp and ls-313 mf30 intraocular lenses
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8901302/
https://www.ncbi.nlm.nih.gov/pubmed/35265369
http://dx.doi.org/10.1155/2022/5645752
work_keys_str_mv AT shenjiying comparisonofvisualoutcomesandqualityoflifeinpatientswithhighmyopiccataractafterimplantationofatlisatri839mpandls313mf30intraocularlenses
AT zhanglimei comparisonofvisualoutcomesandqualityoflifeinpatientswithhighmyopiccataractafterimplantationofatlisatri839mpandls313mf30intraocularlenses
AT nishuang comparisonofvisualoutcomesandqualityoflifeinpatientswithhighmyopiccataractafterimplantationofatlisatri839mpandls313mf30intraocularlenses
AT cailei comparisonofvisualoutcomesandqualityoflifeinpatientswithhighmyopiccataractafterimplantationofatlisatri839mpandls313mf30intraocularlenses
AT guohaike comparisonofvisualoutcomesandqualityoflifeinpatientswithhighmyopiccataractafterimplantationofatlisatri839mpandls313mf30intraocularlenses
AT yangjin comparisonofvisualoutcomesandqualityoflifeinpatientswithhighmyopiccataractafterimplantationofatlisatri839mpandls313mf30intraocularlenses