Cargando…

Novel PEEK Retentive Elements versus Conventional Retentive Elements in Mandibular Overdentures: A Randomized Controlled Trial

BACKGROUND: Many patients suffer from lack of retention of conventional mandibular overdentures due to loss of clip retention over time. Computer-aided design-computer-aided manufacturing (CAD-CAM) milled polyether ether ketone (PEEK) materials may be used for the construction of retentive housing a...

Descripción completa

Detalles Bibliográficos
Autores principales: Sharaf, M. Y., Eskander, Asharaf, Afify, Mohamed
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8901354/
https://www.ncbi.nlm.nih.gov/pubmed/35265135
http://dx.doi.org/10.1155/2022/6947756
_version_ 1784664355867983872
author Sharaf, M. Y.
Eskander, Asharaf
Afify, Mohamed
author_facet Sharaf, M. Y.
Eskander, Asharaf
Afify, Mohamed
author_sort Sharaf, M. Y.
collection PubMed
description BACKGROUND: Many patients suffer from lack of retention of conventional mandibular overdentures due to loss of clip retention over time. Computer-aided design-computer-aided manufacturing (CAD-CAM) milled polyether ether ketone (PEEK) materials may be used for the construction of retentive housing and clips for improving retention of implant-supported overdentures. OBJECTIVE: To compare retention and patient satisfaction of implant-supported mandibular overdentures retained by conventional nylon clip and metal housings for ball attachments versus PEEK clip and housings. METHODS: Twenty-two participants were divided into 2 equal groups (n = 11). The conventional group received implant-supported mandibular overdentures retained by metal housings and nylon retentive elements, while the PEEK group received implant-supported mandibular overdentures retained by PEEK retentive elements and housings. The PEEK retentive elements were made using computer-aided design and computer-aided manufacturing (CAD-CAM). The evaluation included measuring the retention by applying a gradual pulling up force by force meter and patient satisfaction with a 7-point visual analog scale (VAS) at overdenture insertion and 3, 6, and 12 months subsequently by a research interviewer. RESULTS: The PEEK group showed statistically significantly increased retention force (P < 0.05) at the time of insertion (37.6/17.79) and after 3 months (33.9/16.78), 6 months (32.7/15.97), and 12 months (31.65/13.05). The conventional group had a statistically significantly higher mean overall satisfaction (P < 0.05) at the time of insertion (65/82.18). No statistically significant difference was found after 3 months (87.81/84.72). The PEEK group showed statistically significantly higher mean overall satisfaction (P < 0.05) after 6 months (86.36/80.18) and 12 months (85.45/79.54). CONCLUSIONS: According to the results of this study, the PEEK retentive material provided more retention than did the conventional material and led to improved patient satisfaction. The study was registered at clinical trials.gov (https://clinicaltrials.gov/ct2/show/NCT05079048).
format Online
Article
Text
id pubmed-8901354
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-89013542022-03-08 Novel PEEK Retentive Elements versus Conventional Retentive Elements in Mandibular Overdentures: A Randomized Controlled Trial Sharaf, M. Y. Eskander, Asharaf Afify, Mohamed Int J Dent Research Article BACKGROUND: Many patients suffer from lack of retention of conventional mandibular overdentures due to loss of clip retention over time. Computer-aided design-computer-aided manufacturing (CAD-CAM) milled polyether ether ketone (PEEK) materials may be used for the construction of retentive housing and clips for improving retention of implant-supported overdentures. OBJECTIVE: To compare retention and patient satisfaction of implant-supported mandibular overdentures retained by conventional nylon clip and metal housings for ball attachments versus PEEK clip and housings. METHODS: Twenty-two participants were divided into 2 equal groups (n = 11). The conventional group received implant-supported mandibular overdentures retained by metal housings and nylon retentive elements, while the PEEK group received implant-supported mandibular overdentures retained by PEEK retentive elements and housings. The PEEK retentive elements were made using computer-aided design and computer-aided manufacturing (CAD-CAM). The evaluation included measuring the retention by applying a gradual pulling up force by force meter and patient satisfaction with a 7-point visual analog scale (VAS) at overdenture insertion and 3, 6, and 12 months subsequently by a research interviewer. RESULTS: The PEEK group showed statistically significantly increased retention force (P < 0.05) at the time of insertion (37.6/17.79) and after 3 months (33.9/16.78), 6 months (32.7/15.97), and 12 months (31.65/13.05). The conventional group had a statistically significantly higher mean overall satisfaction (P < 0.05) at the time of insertion (65/82.18). No statistically significant difference was found after 3 months (87.81/84.72). The PEEK group showed statistically significantly higher mean overall satisfaction (P < 0.05) after 6 months (86.36/80.18) and 12 months (85.45/79.54). CONCLUSIONS: According to the results of this study, the PEEK retentive material provided more retention than did the conventional material and led to improved patient satisfaction. The study was registered at clinical trials.gov (https://clinicaltrials.gov/ct2/show/NCT05079048). Hindawi 2022-02-28 /pmc/articles/PMC8901354/ /pubmed/35265135 http://dx.doi.org/10.1155/2022/6947756 Text en Copyright © 2022 M. Y. Sharaf et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Sharaf, M. Y.
Eskander, Asharaf
Afify, Mohamed
Novel PEEK Retentive Elements versus Conventional Retentive Elements in Mandibular Overdentures: A Randomized Controlled Trial
title Novel PEEK Retentive Elements versus Conventional Retentive Elements in Mandibular Overdentures: A Randomized Controlled Trial
title_full Novel PEEK Retentive Elements versus Conventional Retentive Elements in Mandibular Overdentures: A Randomized Controlled Trial
title_fullStr Novel PEEK Retentive Elements versus Conventional Retentive Elements in Mandibular Overdentures: A Randomized Controlled Trial
title_full_unstemmed Novel PEEK Retentive Elements versus Conventional Retentive Elements in Mandibular Overdentures: A Randomized Controlled Trial
title_short Novel PEEK Retentive Elements versus Conventional Retentive Elements in Mandibular Overdentures: A Randomized Controlled Trial
title_sort novel peek retentive elements versus conventional retentive elements in mandibular overdentures: a randomized controlled trial
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8901354/
https://www.ncbi.nlm.nih.gov/pubmed/35265135
http://dx.doi.org/10.1155/2022/6947756
work_keys_str_mv AT sharafmy novelpeekretentiveelementsversusconventionalretentiveelementsinmandibularoverdenturesarandomizedcontrolledtrial
AT eskanderasharaf novelpeekretentiveelementsversusconventionalretentiveelementsinmandibularoverdenturesarandomizedcontrolledtrial
AT afifymohamed novelpeekretentiveelementsversusconventionalretentiveelementsinmandibularoverdenturesarandomizedcontrolledtrial