Cargando…

Continuous cardiac thermometry via simultaneous catheter tracking and undersampled radial golden angle acquisition for radiofrequency ablation monitoring

The complexity of the MRI protocol is one of the factors limiting the clinical adoption of MR temperature mapping for real-time monitoring of cardiac ablation procedures and a push-button solution would ease its use. Continuous gradient echo golden angle radial acquisition combined with intra-scan m...

Descripción completa

Detalles Bibliográficos
Autores principales: Yon, Maxime, Delcey, Marylène, Bour, Pierre, Grissom, William, Quesson, Bruno, Ozenne, Valéry
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8901729/
https://www.ncbi.nlm.nih.gov/pubmed/35256627
http://dx.doi.org/10.1038/s41598-022-06927-9
_version_ 1784664433544396800
author Yon, Maxime
Delcey, Marylène
Bour, Pierre
Grissom, William
Quesson, Bruno
Ozenne, Valéry
author_facet Yon, Maxime
Delcey, Marylène
Bour, Pierre
Grissom, William
Quesson, Bruno
Ozenne, Valéry
author_sort Yon, Maxime
collection PubMed
description The complexity of the MRI protocol is one of the factors limiting the clinical adoption of MR temperature mapping for real-time monitoring of cardiac ablation procedures and a push-button solution would ease its use. Continuous gradient echo golden angle radial acquisition combined with intra-scan motion correction and undersampled temperature determination could be a robust and more user-friendly alternative than the ultrafast GRE-EPI sequence which suffers from sensitivity to magnetic field susceptibility artifacts and requires ECG-gating. The goal of this proof-of-concept work is to establish the temperature uncertainty as well as the spatial and temporal resolutions achievable in an Agar-gel phantom and in vivo using this method. GRE radial golden angle acquisitions were used to monitor RF ablations in a phantom and in vivo in two sheep hearts with different slice orientations. In each case, 2D rigid motion correction based on catheter micro-coil signal, tracking its motion, was performed and its impact on the temperature imaging was assessed. The temperature uncertainty was determined for three spatial resolutions (1 × 1 × 3 mm(3), 2 × 2 × 3 mm(3), and 3 × 3 × 3 mm(3)) and three temporal resolutions (0.48, 0.72, and 0.97 s) with undersampling acceleration factors ranging from 2 to 17. The combination of radial golden angle GRE acquisition, simultaneous catheter tracking, intra-scan 2D motion correction, and undersampled thermometry enabled temperature monitoring in the myocardium in vivo during RF ablations with high temporal (< 1 s) and high spatial resolution. The temperature uncertainty ranged from 0.2 ± 0.1 to 1.8 ± 0.2 °C for the various temporal and spatial resolutions and, on average, remained superior to the uncertainty of an EPI acquisition while still allowing clinical monitoring of the RF ablation process. The proposed method is a robust and promising alternative to EPI acquisition to monitor in vivo RF cardiac ablations. Further studies remain required to improve the temperature uncertainty and establish its clinical applicability.
format Online
Article
Text
id pubmed-8901729
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-89017292022-03-08 Continuous cardiac thermometry via simultaneous catheter tracking and undersampled radial golden angle acquisition for radiofrequency ablation monitoring Yon, Maxime Delcey, Marylène Bour, Pierre Grissom, William Quesson, Bruno Ozenne, Valéry Sci Rep Article The complexity of the MRI protocol is one of the factors limiting the clinical adoption of MR temperature mapping for real-time monitoring of cardiac ablation procedures and a push-button solution would ease its use. Continuous gradient echo golden angle radial acquisition combined with intra-scan motion correction and undersampled temperature determination could be a robust and more user-friendly alternative than the ultrafast GRE-EPI sequence which suffers from sensitivity to magnetic field susceptibility artifacts and requires ECG-gating. The goal of this proof-of-concept work is to establish the temperature uncertainty as well as the spatial and temporal resolutions achievable in an Agar-gel phantom and in vivo using this method. GRE radial golden angle acquisitions were used to monitor RF ablations in a phantom and in vivo in two sheep hearts with different slice orientations. In each case, 2D rigid motion correction based on catheter micro-coil signal, tracking its motion, was performed and its impact on the temperature imaging was assessed. The temperature uncertainty was determined for three spatial resolutions (1 × 1 × 3 mm(3), 2 × 2 × 3 mm(3), and 3 × 3 × 3 mm(3)) and three temporal resolutions (0.48, 0.72, and 0.97 s) with undersampling acceleration factors ranging from 2 to 17. The combination of radial golden angle GRE acquisition, simultaneous catheter tracking, intra-scan 2D motion correction, and undersampled thermometry enabled temperature monitoring in the myocardium in vivo during RF ablations with high temporal (< 1 s) and high spatial resolution. The temperature uncertainty ranged from 0.2 ± 0.1 to 1.8 ± 0.2 °C for the various temporal and spatial resolutions and, on average, remained superior to the uncertainty of an EPI acquisition while still allowing clinical monitoring of the RF ablation process. The proposed method is a robust and promising alternative to EPI acquisition to monitor in vivo RF cardiac ablations. Further studies remain required to improve the temperature uncertainty and establish its clinical applicability. Nature Publishing Group UK 2022-03-07 /pmc/articles/PMC8901729/ /pubmed/35256627 http://dx.doi.org/10.1038/s41598-022-06927-9 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Yon, Maxime
Delcey, Marylène
Bour, Pierre
Grissom, William
Quesson, Bruno
Ozenne, Valéry
Continuous cardiac thermometry via simultaneous catheter tracking and undersampled radial golden angle acquisition for radiofrequency ablation monitoring
title Continuous cardiac thermometry via simultaneous catheter tracking and undersampled radial golden angle acquisition for radiofrequency ablation monitoring
title_full Continuous cardiac thermometry via simultaneous catheter tracking and undersampled radial golden angle acquisition for radiofrequency ablation monitoring
title_fullStr Continuous cardiac thermometry via simultaneous catheter tracking and undersampled radial golden angle acquisition for radiofrequency ablation monitoring
title_full_unstemmed Continuous cardiac thermometry via simultaneous catheter tracking and undersampled radial golden angle acquisition for radiofrequency ablation monitoring
title_short Continuous cardiac thermometry via simultaneous catheter tracking and undersampled radial golden angle acquisition for radiofrequency ablation monitoring
title_sort continuous cardiac thermometry via simultaneous catheter tracking and undersampled radial golden angle acquisition for radiofrequency ablation monitoring
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8901729/
https://www.ncbi.nlm.nih.gov/pubmed/35256627
http://dx.doi.org/10.1038/s41598-022-06927-9
work_keys_str_mv AT yonmaxime continuouscardiacthermometryviasimultaneouscathetertrackingandundersampledradialgoldenangleacquisitionforradiofrequencyablationmonitoring
AT delceymarylene continuouscardiacthermometryviasimultaneouscathetertrackingandundersampledradialgoldenangleacquisitionforradiofrequencyablationmonitoring
AT bourpierre continuouscardiacthermometryviasimultaneouscathetertrackingandundersampledradialgoldenangleacquisitionforradiofrequencyablationmonitoring
AT grissomwilliam continuouscardiacthermometryviasimultaneouscathetertrackingandundersampledradialgoldenangleacquisitionforradiofrequencyablationmonitoring
AT quessonbruno continuouscardiacthermometryviasimultaneouscathetertrackingandundersampledradialgoldenangleacquisitionforradiofrequencyablationmonitoring
AT ozennevalery continuouscardiacthermometryviasimultaneouscathetertrackingandundersampledradialgoldenangleacquisitionforradiofrequencyablationmonitoring