Cargando…

Evaluation of interproximal reduction in individual teeth, and full arch assessment in clear aligner therapy: digital planning versus 3D model analysis after reduction

AIM: To evaluate the correspondence between the interproximal reduction (IPR) performed clinically and that programmed in ClinCheck® and further assess which teeth showed an amount of implemented IPR (I-IPR) that corresponds with that programmed in ClinCheck®. MATERIALS AND METHODS: Pre- (T0) and po...

Descripción completa

Detalles Bibliográficos
Autores principales: Hariharan, Amirtha, Arqub, Sarah Abu, Gandhi, Vaibhav, Da Cunha Godoy, Lucas, Kuo, Chia-Ling, Uribe, Flavio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8901911/
https://www.ncbi.nlm.nih.gov/pubmed/35254555
http://dx.doi.org/10.1186/s40510-022-00403-w
_version_ 1784664475106803712
author Hariharan, Amirtha
Arqub, Sarah Abu
Gandhi, Vaibhav
Da Cunha Godoy, Lucas
Kuo, Chia-Ling
Uribe, Flavio
author_facet Hariharan, Amirtha
Arqub, Sarah Abu
Gandhi, Vaibhav
Da Cunha Godoy, Lucas
Kuo, Chia-Ling
Uribe, Flavio
author_sort Hariharan, Amirtha
collection PubMed
description AIM: To evaluate the correspondence between the interproximal reduction (IPR) performed clinically and that programmed in ClinCheck® and further assess which teeth showed an amount of implemented IPR (I-IPR) that corresponds with that programmed in ClinCheck®. MATERIALS AND METHODS: Pre- (T0) and post-treatment (T1) ClinCheck® digital models for 75 subjects (30 males and 45 females), mean age (38 ± 15) years, were included. To calculate the amount of I-IPR, Ortho Analyzer software (3Shape, Copenhagen, Denmark) was used to measure the mesiodistal widths for the maxillary and mandibular teeth from second premolar to the contralateral second premolar on the initial (T0) and final (T1) STL models. I- IPR performed by tooth was obtained by comparing the mesiodistal width of each tooth at T0 and T1. The amount of programmed IPR (P-IPR) in ClinCheck® was compared to that implemented clinically using the following formula: IPR difference = (P-IPR) − (I-IPR). RESULTS: Statistically significant differences were observed between the average value of digitally programmed and implemented IPR per tooth for both the maxillary (p < .0001) and mandibular (p < .0001) teeth. The mean P-IPR for the maxillary teeth was 0.28 ± 0.16 mm versus the mean I-IPR of 0.15 ± 0.15 mm. In the mandibular arch, the mean P-IPR was 0.31 ± 0.17 mm, while the I-IPR was 0.17 ± 0.16 mm. The mean I-IPR was consistently lower than the mean P-IPR regardless of teeth and sites (p < 0.0001). The difference between the P-IPR compared to the I-IPR was larger for mandibular anterior teeth than for maxillary anterior teeth (p = 0.0302) and larger for maxillary posterior teeth than mandibular posterior teeth (p = 0.0059). CONCLUSION: The amount of implemented-IPR in clear aligner therapy is less than that digitally programmed for most teeth. Regardless of the regions, I-IPR was consistently lower than that programmed. Mandibular anterior teeth and maxillary posterior teeth showed greater discrepancy between P-IPR and I-IPR than the maxillary anterior and mandibular posteriors. Further prospective studies are needed to determine the factors affecting the precision of IPR and the clinical implications of a significantly reduced I-IPR on treatment outcomes.
format Online
Article
Text
id pubmed-8901911
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-89019112022-03-15 Evaluation of interproximal reduction in individual teeth, and full arch assessment in clear aligner therapy: digital planning versus 3D model analysis after reduction Hariharan, Amirtha Arqub, Sarah Abu Gandhi, Vaibhav Da Cunha Godoy, Lucas Kuo, Chia-Ling Uribe, Flavio Prog Orthod Research AIM: To evaluate the correspondence between the interproximal reduction (IPR) performed clinically and that programmed in ClinCheck® and further assess which teeth showed an amount of implemented IPR (I-IPR) that corresponds with that programmed in ClinCheck®. MATERIALS AND METHODS: Pre- (T0) and post-treatment (T1) ClinCheck® digital models for 75 subjects (30 males and 45 females), mean age (38 ± 15) years, were included. To calculate the amount of I-IPR, Ortho Analyzer software (3Shape, Copenhagen, Denmark) was used to measure the mesiodistal widths for the maxillary and mandibular teeth from second premolar to the contralateral second premolar on the initial (T0) and final (T1) STL models. I- IPR performed by tooth was obtained by comparing the mesiodistal width of each tooth at T0 and T1. The amount of programmed IPR (P-IPR) in ClinCheck® was compared to that implemented clinically using the following formula: IPR difference = (P-IPR) − (I-IPR). RESULTS: Statistically significant differences were observed between the average value of digitally programmed and implemented IPR per tooth for both the maxillary (p < .0001) and mandibular (p < .0001) teeth. The mean P-IPR for the maxillary teeth was 0.28 ± 0.16 mm versus the mean I-IPR of 0.15 ± 0.15 mm. In the mandibular arch, the mean P-IPR was 0.31 ± 0.17 mm, while the I-IPR was 0.17 ± 0.16 mm. The mean I-IPR was consistently lower than the mean P-IPR regardless of teeth and sites (p < 0.0001). The difference between the P-IPR compared to the I-IPR was larger for mandibular anterior teeth than for maxillary anterior teeth (p = 0.0302) and larger for maxillary posterior teeth than mandibular posterior teeth (p = 0.0059). CONCLUSION: The amount of implemented-IPR in clear aligner therapy is less than that digitally programmed for most teeth. Regardless of the regions, I-IPR was consistently lower than that programmed. Mandibular anterior teeth and maxillary posterior teeth showed greater discrepancy between P-IPR and I-IPR than the maxillary anterior and mandibular posteriors. Further prospective studies are needed to determine the factors affecting the precision of IPR and the clinical implications of a significantly reduced I-IPR on treatment outcomes. Springer Berlin Heidelberg 2022-03-07 /pmc/articles/PMC8901911/ /pubmed/35254555 http://dx.doi.org/10.1186/s40510-022-00403-w Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Research
Hariharan, Amirtha
Arqub, Sarah Abu
Gandhi, Vaibhav
Da Cunha Godoy, Lucas
Kuo, Chia-Ling
Uribe, Flavio
Evaluation of interproximal reduction in individual teeth, and full arch assessment in clear aligner therapy: digital planning versus 3D model analysis after reduction
title Evaluation of interproximal reduction in individual teeth, and full arch assessment in clear aligner therapy: digital planning versus 3D model analysis after reduction
title_full Evaluation of interproximal reduction in individual teeth, and full arch assessment in clear aligner therapy: digital planning versus 3D model analysis after reduction
title_fullStr Evaluation of interproximal reduction in individual teeth, and full arch assessment in clear aligner therapy: digital planning versus 3D model analysis after reduction
title_full_unstemmed Evaluation of interproximal reduction in individual teeth, and full arch assessment in clear aligner therapy: digital planning versus 3D model analysis after reduction
title_short Evaluation of interproximal reduction in individual teeth, and full arch assessment in clear aligner therapy: digital planning versus 3D model analysis after reduction
title_sort evaluation of interproximal reduction in individual teeth, and full arch assessment in clear aligner therapy: digital planning versus 3d model analysis after reduction
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8901911/
https://www.ncbi.nlm.nih.gov/pubmed/35254555
http://dx.doi.org/10.1186/s40510-022-00403-w
work_keys_str_mv AT hariharanamirtha evaluationofinterproximalreductioninindividualteethandfullarchassessmentinclearalignertherapydigitalplanningversus3dmodelanalysisafterreduction
AT arqubsarahabu evaluationofinterproximalreductioninindividualteethandfullarchassessmentinclearalignertherapydigitalplanningversus3dmodelanalysisafterreduction
AT gandhivaibhav evaluationofinterproximalreductioninindividualteethandfullarchassessmentinclearalignertherapydigitalplanningversus3dmodelanalysisafterreduction
AT dacunhagodoylucas evaluationofinterproximalreductioninindividualteethandfullarchassessmentinclearalignertherapydigitalplanningversus3dmodelanalysisafterreduction
AT kuochialing evaluationofinterproximalreductioninindividualteethandfullarchassessmentinclearalignertherapydigitalplanningversus3dmodelanalysisafterreduction
AT uribeflavio evaluationofinterproximalreductioninindividualteethandfullarchassessmentinclearalignertherapydigitalplanningversus3dmodelanalysisafterreduction