Cargando…
Three-dimensional reconstruction and virtual reposition of fragments compared to two dimensional measurements of midshaft clavicle fracture shortening
BACKGROUND: Midshaft clavicle fracture shortening measurement is a reported key element for indication to surgical management and reporting of clinical trials. Determination of pre-fracture clavicle length for shortening measurement remains an unresolved issue. The purpose of the study was to assess...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8903646/ https://www.ncbi.nlm.nih.gov/pubmed/35255891 http://dx.doi.org/10.1186/s12891-022-05173-4 |
_version_ | 1784664785052237824 |
---|---|
author | Öztürk, Mehmet Paulin, Emilie Charbonnier, Caecilia Dupuis-Lozeron, Elise Holzer, Nicolas |
author_facet | Öztürk, Mehmet Paulin, Emilie Charbonnier, Caecilia Dupuis-Lozeron, Elise Holzer, Nicolas |
author_sort | Öztürk, Mehmet |
collection | PubMed |
description | BACKGROUND: Midshaft clavicle fracture shortening measurement is a reported key element for indication to surgical management and reporting of clinical trials. Determination of pre-fracture clavicle length for shortening measurement remains an unresolved issue. The purpose of the study was to assess accuracy of a novel technique of three-dimensional reconstruction and virtual reposition of bone fragments (3D-VR) for determination of pre-fracture clavicle length and measurement of shortening. METHODS: Accuracy of 3D-VR measurements was assessed using 5 synthetic bone clavicle fracture models. Measurements were compared between caliper and 3D-VR technique measurements. Correlation between 3D-VR and 2D measurements on standard radiographs was assessed on a cohort of 20 midshaft fractures. Four different methods for 2D measurements were assessed. RESULTS: Mean difference between caliper measurements and 3D-VR was 0.74 mm (95CI = − 2.51;3.98) (p = 0.56) on synthetic fracture models. Mean differences between 3D-VR and standard radiograph shortening measurement methods were 11.95 mm (95CI = 7.44;16.46) for method 1 (Jeray et al.) and 9.28 mm (95CI = 4.77;13.79) for method 2 (Smekal et al.) (p < 0.05). Differences were − 1.02 mm (95CI = − 5.53;3.48) for method 3 (Silva et al.) and − 2.04 mm (95CI = − 6.55;2.47) for method 4 (own method). Interobserver correlation ranged between 0.85 and 0.99. A false positive threshold of 20 mm was measured by the two observers in 25% of the case according to method of method 1, 30–35% with method 2, 15% with method 3 et al. and 5–10% with the method 4. CONCLUSION: 3D VR is accurate in measuring midshaft clavicle fracture length and shortening. Two dimensional measurements may be used for approximation of clavicular shortening. |
format | Online Article Text |
id | pubmed-8903646 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-89036462022-03-18 Three-dimensional reconstruction and virtual reposition of fragments compared to two dimensional measurements of midshaft clavicle fracture shortening Öztürk, Mehmet Paulin, Emilie Charbonnier, Caecilia Dupuis-Lozeron, Elise Holzer, Nicolas BMC Musculoskelet Disord Research BACKGROUND: Midshaft clavicle fracture shortening measurement is a reported key element for indication to surgical management and reporting of clinical trials. Determination of pre-fracture clavicle length for shortening measurement remains an unresolved issue. The purpose of the study was to assess accuracy of a novel technique of three-dimensional reconstruction and virtual reposition of bone fragments (3D-VR) for determination of pre-fracture clavicle length and measurement of shortening. METHODS: Accuracy of 3D-VR measurements was assessed using 5 synthetic bone clavicle fracture models. Measurements were compared between caliper and 3D-VR technique measurements. Correlation between 3D-VR and 2D measurements on standard radiographs was assessed on a cohort of 20 midshaft fractures. Four different methods for 2D measurements were assessed. RESULTS: Mean difference between caliper measurements and 3D-VR was 0.74 mm (95CI = − 2.51;3.98) (p = 0.56) on synthetic fracture models. Mean differences between 3D-VR and standard radiograph shortening measurement methods were 11.95 mm (95CI = 7.44;16.46) for method 1 (Jeray et al.) and 9.28 mm (95CI = 4.77;13.79) for method 2 (Smekal et al.) (p < 0.05). Differences were − 1.02 mm (95CI = − 5.53;3.48) for method 3 (Silva et al.) and − 2.04 mm (95CI = − 6.55;2.47) for method 4 (own method). Interobserver correlation ranged between 0.85 and 0.99. A false positive threshold of 20 mm was measured by the two observers in 25% of the case according to method of method 1, 30–35% with method 2, 15% with method 3 et al. and 5–10% with the method 4. CONCLUSION: 3D VR is accurate in measuring midshaft clavicle fracture length and shortening. Two dimensional measurements may be used for approximation of clavicular shortening. BioMed Central 2022-03-07 /pmc/articles/PMC8903646/ /pubmed/35255891 http://dx.doi.org/10.1186/s12891-022-05173-4 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Öztürk, Mehmet Paulin, Emilie Charbonnier, Caecilia Dupuis-Lozeron, Elise Holzer, Nicolas Three-dimensional reconstruction and virtual reposition of fragments compared to two dimensional measurements of midshaft clavicle fracture shortening |
title | Three-dimensional reconstruction and virtual reposition of fragments compared to two dimensional measurements of midshaft clavicle fracture shortening |
title_full | Three-dimensional reconstruction and virtual reposition of fragments compared to two dimensional measurements of midshaft clavicle fracture shortening |
title_fullStr | Three-dimensional reconstruction and virtual reposition of fragments compared to two dimensional measurements of midshaft clavicle fracture shortening |
title_full_unstemmed | Three-dimensional reconstruction and virtual reposition of fragments compared to two dimensional measurements of midshaft clavicle fracture shortening |
title_short | Three-dimensional reconstruction and virtual reposition of fragments compared to two dimensional measurements of midshaft clavicle fracture shortening |
title_sort | three-dimensional reconstruction and virtual reposition of fragments compared to two dimensional measurements of midshaft clavicle fracture shortening |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8903646/ https://www.ncbi.nlm.nih.gov/pubmed/35255891 http://dx.doi.org/10.1186/s12891-022-05173-4 |
work_keys_str_mv | AT ozturkmehmet threedimensionalreconstructionandvirtualrepositionoffragmentscomparedtotwodimensionalmeasurementsofmidshaftclaviclefractureshortening AT paulinemilie threedimensionalreconstructionandvirtualrepositionoffragmentscomparedtotwodimensionalmeasurementsofmidshaftclaviclefractureshortening AT charbonniercaecilia threedimensionalreconstructionandvirtualrepositionoffragmentscomparedtotwodimensionalmeasurementsofmidshaftclaviclefractureshortening AT dupuislozeronelise threedimensionalreconstructionandvirtualrepositionoffragmentscomparedtotwodimensionalmeasurementsofmidshaftclaviclefractureshortening AT holzernicolas threedimensionalreconstructionandvirtualrepositionoffragmentscomparedtotwodimensionalmeasurementsofmidshaftclaviclefractureshortening |