Cargando…

Effects of transcutaneous electrical nerve stimulation on myocardial protection in patients undergoing aortic valve replacement: a randomized clinical trial

BACKGROUND: Cardiopulmonary bypass-related myocardial ischemia-reperfusion injury is a major contributor to postoperative morbidity. Although transcutaneous electrical nerve stimulation (TENS) has been found to have cardioprotective effects in animal studies and healthy volunteers, its effects on ca...

Descripción completa

Detalles Bibliográficos
Autores principales: Cho, Youn Joung, Jung, Dhong-Eun, Nam, Karam, Bae, Jinyoung, Lee, Seohee, Jeon, Yunseok
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8905743/
https://www.ncbi.nlm.nih.gov/pubmed/35264104
http://dx.doi.org/10.1186/s12871-022-01611-x
_version_ 1784665257642295296
author Cho, Youn Joung
Jung, Dhong-Eun
Nam, Karam
Bae, Jinyoung
Lee, Seohee
Jeon, Yunseok
author_facet Cho, Youn Joung
Jung, Dhong-Eun
Nam, Karam
Bae, Jinyoung
Lee, Seohee
Jeon, Yunseok
author_sort Cho, Youn Joung
collection PubMed
description BACKGROUND: Cardiopulmonary bypass-related myocardial ischemia-reperfusion injury is a major contributor to postoperative morbidity. Although transcutaneous electrical nerve stimulation (TENS) has been found to have cardioprotective effects in animal studies and healthy volunteers, its effects on cardiac surgery under cardiopulmonary bypass patients have not been evaluated. We investigated the effects of TENS on myocardial protection in patients undergoing aortic valve replacement surgery using cardiopulmonary bypass. METHODS: Thirty patients were randomized to receive TENS or sham in three different anesthetic states – pre-anesthesia, sevoflurane, or propofol (each n = 5). TENS was applied with a pulse width of 385 μs and a frequency of 10 Hz using two surface electrodes at the upper arm for 30 min. Sham treatment was provided without stimulation. The primary outcome was the difference in myocardial infarct size following ischemia-reperfusion injury in rat hearts perfused with pre- and post-TENS plasma dialysate obtained from the patients using Langendorff perfusion system. The cardioprotective effects of TENS were determined by assessing reduction in infarct size following treatment. RESULTS: There were no differences in myocardial infarct size between pre- and post-treatment in any group (41.4 ± 4.3% vs. 36.7 ± 5.3%, 39.8 ± 7.3% vs. 27.8 ± 12.0%, and 41.6 ± 2.2% vs. 37.8 ± 7.6%; p = 0.080, 0.152, and 0.353 in the pre-anesthesia, sevoflurane, and propofol groups, respectively). CONCLUSIONS: In our study, TENS did not show a cardioprotective effect in patients undergoing aortic valve replacement surgery. TRIAL REGISTRATION: This study was registered at clinicaltrials.gov (NCT03859115, on March 1, 2019). SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12871-022-01611-x.
format Online
Article
Text
id pubmed-8905743
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-89057432022-03-18 Effects of transcutaneous electrical nerve stimulation on myocardial protection in patients undergoing aortic valve replacement: a randomized clinical trial Cho, Youn Joung Jung, Dhong-Eun Nam, Karam Bae, Jinyoung Lee, Seohee Jeon, Yunseok BMC Anesthesiol Research BACKGROUND: Cardiopulmonary bypass-related myocardial ischemia-reperfusion injury is a major contributor to postoperative morbidity. Although transcutaneous electrical nerve stimulation (TENS) has been found to have cardioprotective effects in animal studies and healthy volunteers, its effects on cardiac surgery under cardiopulmonary bypass patients have not been evaluated. We investigated the effects of TENS on myocardial protection in patients undergoing aortic valve replacement surgery using cardiopulmonary bypass. METHODS: Thirty patients were randomized to receive TENS or sham in three different anesthetic states – pre-anesthesia, sevoflurane, or propofol (each n = 5). TENS was applied with a pulse width of 385 μs and a frequency of 10 Hz using two surface electrodes at the upper arm for 30 min. Sham treatment was provided without stimulation. The primary outcome was the difference in myocardial infarct size following ischemia-reperfusion injury in rat hearts perfused with pre- and post-TENS plasma dialysate obtained from the patients using Langendorff perfusion system. The cardioprotective effects of TENS were determined by assessing reduction in infarct size following treatment. RESULTS: There were no differences in myocardial infarct size between pre- and post-treatment in any group (41.4 ± 4.3% vs. 36.7 ± 5.3%, 39.8 ± 7.3% vs. 27.8 ± 12.0%, and 41.6 ± 2.2% vs. 37.8 ± 7.6%; p = 0.080, 0.152, and 0.353 in the pre-anesthesia, sevoflurane, and propofol groups, respectively). CONCLUSIONS: In our study, TENS did not show a cardioprotective effect in patients undergoing aortic valve replacement surgery. TRIAL REGISTRATION: This study was registered at clinicaltrials.gov (NCT03859115, on March 1, 2019). SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12871-022-01611-x. BioMed Central 2022-03-09 /pmc/articles/PMC8905743/ /pubmed/35264104 http://dx.doi.org/10.1186/s12871-022-01611-x Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Cho, Youn Joung
Jung, Dhong-Eun
Nam, Karam
Bae, Jinyoung
Lee, Seohee
Jeon, Yunseok
Effects of transcutaneous electrical nerve stimulation on myocardial protection in patients undergoing aortic valve replacement: a randomized clinical trial
title Effects of transcutaneous electrical nerve stimulation on myocardial protection in patients undergoing aortic valve replacement: a randomized clinical trial
title_full Effects of transcutaneous electrical nerve stimulation on myocardial protection in patients undergoing aortic valve replacement: a randomized clinical trial
title_fullStr Effects of transcutaneous electrical nerve stimulation on myocardial protection in patients undergoing aortic valve replacement: a randomized clinical trial
title_full_unstemmed Effects of transcutaneous electrical nerve stimulation on myocardial protection in patients undergoing aortic valve replacement: a randomized clinical trial
title_short Effects of transcutaneous electrical nerve stimulation on myocardial protection in patients undergoing aortic valve replacement: a randomized clinical trial
title_sort effects of transcutaneous electrical nerve stimulation on myocardial protection in patients undergoing aortic valve replacement: a randomized clinical trial
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8905743/
https://www.ncbi.nlm.nih.gov/pubmed/35264104
http://dx.doi.org/10.1186/s12871-022-01611-x
work_keys_str_mv AT choyounjoung effectsoftranscutaneouselectricalnervestimulationonmyocardialprotectioninpatientsundergoingaorticvalvereplacementarandomizedclinicaltrial
AT jungdhongeun effectsoftranscutaneouselectricalnervestimulationonmyocardialprotectioninpatientsundergoingaorticvalvereplacementarandomizedclinicaltrial
AT namkaram effectsoftranscutaneouselectricalnervestimulationonmyocardialprotectioninpatientsundergoingaorticvalvereplacementarandomizedclinicaltrial
AT baejinyoung effectsoftranscutaneouselectricalnervestimulationonmyocardialprotectioninpatientsundergoingaorticvalvereplacementarandomizedclinicaltrial
AT leeseohee effectsoftranscutaneouselectricalnervestimulationonmyocardialprotectioninpatientsundergoingaorticvalvereplacementarandomizedclinicaltrial
AT jeonyunseok effectsoftranscutaneouselectricalnervestimulationonmyocardialprotectioninpatientsundergoingaorticvalvereplacementarandomizedclinicaltrial