Accuracy evaluation of surface registration algorithm using normal distribution transform in stereotactic body radiotherapy/radiosurgery: A phantom study

PURPOSE: To evaluate a feasibility of normal distribution transform (NDT) algorithm compared with the iterative closest point (ICP) method as a useful surface registration in stereotactic body radiotherapy (SBRT)/stereotactic radiosurgery (SRS). METHODS: Point cloud images using the 3D triangulation...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Haenghwa, Park, Jeong‐Mee, Kim, Kwang Hyeon, Lee, Dong‐Hoon, Sohn, Moon‐Jun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8906233/
https://www.ncbi.nlm.nih.gov/pubmed/34985179
http://dx.doi.org/10.1002/acm2.13521
_version_ 1784665365464219648
author Lee, Haenghwa
Park, Jeong‐Mee
Kim, Kwang Hyeon
Lee, Dong‐Hoon
Sohn, Moon‐Jun
author_facet Lee, Haenghwa
Park, Jeong‐Mee
Kim, Kwang Hyeon
Lee, Dong‐Hoon
Sohn, Moon‐Jun
author_sort Lee, Haenghwa
collection PubMed
description PURPOSE: To evaluate a feasibility of normal distribution transform (NDT) algorithm compared with the iterative closest point (ICP) method as a useful surface registration in stereotactic body radiotherapy (SBRT)/stereotactic radiosurgery (SRS). METHODS: Point cloud images using the 3D triangulation technology were obtained from a depth camera‐based optical imaging (OSI) system equipped in a radiosurgery room. Two surface registration algorithms, NDT and ICP, were used to measure and compare the discrepancy values between the reference and the current surfaces during the positioning of the patient. The performance evaluation was investigated by calculating the registration error and root‐mean‐square (RMS) values for the surface model, reposition, and target accuracy, which were analyzed statistically using a paired t‐test. RESULTS: For surface model accuracy, the average of the registration error and RMS values were measured as 3.56 ± 2.20 mm and 6.98 ± 1.89 mm for ICP method, and 1.76 ± 1.32 mm and 3.58 ± 1.30 mm for NDT method (p < 0.05). For reposition accuracy, the average registration error and RMS values were calculated as 1.41 ± 0.98 mm and 2.53 ± 1.64 mm using ICP method, and 0.92 ± 0.61 mm and 1.75 ± 0.80 mm using NDT method (p = 0.005). The overall target accuracy using the NDT method reduced the average of the reposition error and overall RMS value by 0.71 and 1.32 mm, respectively, compared to the ICP method (p = 0.03). CONCLUSIONS: We found that the surface registration algorithm based on NDT method provides more reliable accuracy in the values of surface model, reposition, and target accuracies than the classic ICP method. The NDT method in OSI systems offers reasonable accuracy in SBRT/SRS.
format Online
Article
Text
id pubmed-8906233
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-89062332022-03-10 Accuracy evaluation of surface registration algorithm using normal distribution transform in stereotactic body radiotherapy/radiosurgery: A phantom study Lee, Haenghwa Park, Jeong‐Mee Kim, Kwang Hyeon Lee, Dong‐Hoon Sohn, Moon‐Jun J Appl Clin Med Phys Radiation Oncology Physics PURPOSE: To evaluate a feasibility of normal distribution transform (NDT) algorithm compared with the iterative closest point (ICP) method as a useful surface registration in stereotactic body radiotherapy (SBRT)/stereotactic radiosurgery (SRS). METHODS: Point cloud images using the 3D triangulation technology were obtained from a depth camera‐based optical imaging (OSI) system equipped in a radiosurgery room. Two surface registration algorithms, NDT and ICP, were used to measure and compare the discrepancy values between the reference and the current surfaces during the positioning of the patient. The performance evaluation was investigated by calculating the registration error and root‐mean‐square (RMS) values for the surface model, reposition, and target accuracy, which were analyzed statistically using a paired t‐test. RESULTS: For surface model accuracy, the average of the registration error and RMS values were measured as 3.56 ± 2.20 mm and 6.98 ± 1.89 mm for ICP method, and 1.76 ± 1.32 mm and 3.58 ± 1.30 mm for NDT method (p < 0.05). For reposition accuracy, the average registration error and RMS values were calculated as 1.41 ± 0.98 mm and 2.53 ± 1.64 mm using ICP method, and 0.92 ± 0.61 mm and 1.75 ± 0.80 mm using NDT method (p = 0.005). The overall target accuracy using the NDT method reduced the average of the reposition error and overall RMS value by 0.71 and 1.32 mm, respectively, compared to the ICP method (p = 0.03). CONCLUSIONS: We found that the surface registration algorithm based on NDT method provides more reliable accuracy in the values of surface model, reposition, and target accuracies than the classic ICP method. The NDT method in OSI systems offers reasonable accuracy in SBRT/SRS. John Wiley and Sons Inc. 2022-01-05 /pmc/articles/PMC8906233/ /pubmed/34985179 http://dx.doi.org/10.1002/acm2.13521 Text en © 2022 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, LLC on behalf of The American Association of Physicists in Medicine https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Lee, Haenghwa
Park, Jeong‐Mee
Kim, Kwang Hyeon
Lee, Dong‐Hoon
Sohn, Moon‐Jun
Accuracy evaluation of surface registration algorithm using normal distribution transform in stereotactic body radiotherapy/radiosurgery: A phantom study
title Accuracy evaluation of surface registration algorithm using normal distribution transform in stereotactic body radiotherapy/radiosurgery: A phantom study
title_full Accuracy evaluation of surface registration algorithm using normal distribution transform in stereotactic body radiotherapy/radiosurgery: A phantom study
title_fullStr Accuracy evaluation of surface registration algorithm using normal distribution transform in stereotactic body radiotherapy/radiosurgery: A phantom study
title_full_unstemmed Accuracy evaluation of surface registration algorithm using normal distribution transform in stereotactic body radiotherapy/radiosurgery: A phantom study
title_short Accuracy evaluation of surface registration algorithm using normal distribution transform in stereotactic body radiotherapy/radiosurgery: A phantom study
title_sort accuracy evaluation of surface registration algorithm using normal distribution transform in stereotactic body radiotherapy/radiosurgery: a phantom study
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8906233/
https://www.ncbi.nlm.nih.gov/pubmed/34985179
http://dx.doi.org/10.1002/acm2.13521
work_keys_str_mv AT leehaenghwa accuracyevaluationofsurfaceregistrationalgorithmusingnormaldistributiontransforminstereotacticbodyradiotherapyradiosurgeryaphantomstudy
AT parkjeongmee accuracyevaluationofsurfaceregistrationalgorithmusingnormaldistributiontransforminstereotacticbodyradiotherapyradiosurgeryaphantomstudy
AT kimkwanghyeon accuracyevaluationofsurfaceregistrationalgorithmusingnormaldistributiontransforminstereotacticbodyradiotherapyradiosurgeryaphantomstudy
AT leedonghoon accuracyevaluationofsurfaceregistrationalgorithmusingnormaldistributiontransforminstereotacticbodyradiotherapyradiosurgeryaphantomstudy
AT sohnmoonjun accuracyevaluationofsurfaceregistrationalgorithmusingnormaldistributiontransforminstereotacticbodyradiotherapyradiosurgeryaphantomstudy