Effect of a Novel Pocket Compression Device on Hematomas Following Cardiac Electronic Device Implantation in Patients Receiving Direct Oral Anticoagulants
BACKGROUND: A pocket hematoma is a well-recognized complication that occurs after pacemaker or defibrillator implantation. It is associated with increased pocket infection and hospital stay. Patients suffering from atrial fibrillation and undergoing cardiovascular electronic implantable device (CIED...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8907568/ https://www.ncbi.nlm.nih.gov/pubmed/35282349 http://dx.doi.org/10.3389/fcvm.2022.817453 |
_version_ | 1784665675388682240 |
---|---|
author | Fei, Ye-Ping Wang, Lei Zhu, Chun-Yan Sun, Jing-Chao Hu, Hui-Lin Zhai, Chang-Lin He, Chao-Jie |
author_facet | Fei, Ye-Ping Wang, Lei Zhu, Chun-Yan Sun, Jing-Chao Hu, Hui-Lin Zhai, Chang-Lin He, Chao-Jie |
author_sort | Fei, Ye-Ping |
collection | PubMed |
description | BACKGROUND: A pocket hematoma is a well-recognized complication that occurs after pacemaker or defibrillator implantation. It is associated with increased pocket infection and hospital stay. Patients suffering from atrial fibrillation and undergoing cardiovascular electronic implantable device (CIED) surgery are widely prescribed and treated with direct oral anticoagulants (DOACs). In this study, the use of a novel compression device was evaluated to examine its ability to decrease the incidence of pocket hematomas following device implantation with uninterrupted DOACs. METHODS: A total of 204 participants who received DOACs and underwent CIED implantation were randomized into an experimental group (novel compression device) and a control group (elastic adhesive tape with a sandbag). The primary outcome was pocket hematoma, and the secondary outcomes were skin erosions and patient comfort score. Grade 3 hematoma was defined as a hematoma that required anticoagulation therapy interruption, re-operation, or prolonged hospital stay. RESULTS: The baseline characteristics of both groups had no significant differences. The incidence of grades 1 and 2 hematomas was significantly lower in the compression device group than in the conventional pressure dressing group (7.8 vs. 23.5 and 2.0 vs. 5.9%, respectively; P < 0.01). Grade 3 hematoma occurred in 2 of 102 patients in the experimental group and 7 of 102 patients in the control group (2.0 vs. 6.9%; P = 0.03). The incidence rates of skin erosion were significantly lower, and the patient comfort score was much higher in the compression device group than in the control group (P < 0.01). Multivariable logistic regression analysis showed that the use of novel compression device was a significant protective factor for pocket hematoma (OR = 0.42; 95% CI, 0.29–0.69, P = 0.01). CONCLUSIONS: The incidence of pocket hematomas and skin erosions significantly decreases when the proposed compression device is used for patients undergoing device implantation with uninterrupted DOACs. Thus, the length of hospital stay and re-operation rate can be reduced, and patient comfort can be improved. CLINICAL TRIAL REGISTRATION: http://www.chictr.org.cn, identifier: ChiCTR2100049430. |
format | Online Article Text |
id | pubmed-8907568 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-89075682022-03-11 Effect of a Novel Pocket Compression Device on Hematomas Following Cardiac Electronic Device Implantation in Patients Receiving Direct Oral Anticoagulants Fei, Ye-Ping Wang, Lei Zhu, Chun-Yan Sun, Jing-Chao Hu, Hui-Lin Zhai, Chang-Lin He, Chao-Jie Front Cardiovasc Med Cardiovascular Medicine BACKGROUND: A pocket hematoma is a well-recognized complication that occurs after pacemaker or defibrillator implantation. It is associated with increased pocket infection and hospital stay. Patients suffering from atrial fibrillation and undergoing cardiovascular electronic implantable device (CIED) surgery are widely prescribed and treated with direct oral anticoagulants (DOACs). In this study, the use of a novel compression device was evaluated to examine its ability to decrease the incidence of pocket hematomas following device implantation with uninterrupted DOACs. METHODS: A total of 204 participants who received DOACs and underwent CIED implantation were randomized into an experimental group (novel compression device) and a control group (elastic adhesive tape with a sandbag). The primary outcome was pocket hematoma, and the secondary outcomes were skin erosions and patient comfort score. Grade 3 hematoma was defined as a hematoma that required anticoagulation therapy interruption, re-operation, or prolonged hospital stay. RESULTS: The baseline characteristics of both groups had no significant differences. The incidence of grades 1 and 2 hematomas was significantly lower in the compression device group than in the conventional pressure dressing group (7.8 vs. 23.5 and 2.0 vs. 5.9%, respectively; P < 0.01). Grade 3 hematoma occurred in 2 of 102 patients in the experimental group and 7 of 102 patients in the control group (2.0 vs. 6.9%; P = 0.03). The incidence rates of skin erosion were significantly lower, and the patient comfort score was much higher in the compression device group than in the control group (P < 0.01). Multivariable logistic regression analysis showed that the use of novel compression device was a significant protective factor for pocket hematoma (OR = 0.42; 95% CI, 0.29–0.69, P = 0.01). CONCLUSIONS: The incidence of pocket hematomas and skin erosions significantly decreases when the proposed compression device is used for patients undergoing device implantation with uninterrupted DOACs. Thus, the length of hospital stay and re-operation rate can be reduced, and patient comfort can be improved. CLINICAL TRIAL REGISTRATION: http://www.chictr.org.cn, identifier: ChiCTR2100049430. Frontiers Media S.A. 2022-02-24 /pmc/articles/PMC8907568/ /pubmed/35282349 http://dx.doi.org/10.3389/fcvm.2022.817453 Text en Copyright © 2022 Fei, Wang, Zhu, Sun, Hu, Zhai and He. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Cardiovascular Medicine Fei, Ye-Ping Wang, Lei Zhu, Chun-Yan Sun, Jing-Chao Hu, Hui-Lin Zhai, Chang-Lin He, Chao-Jie Effect of a Novel Pocket Compression Device on Hematomas Following Cardiac Electronic Device Implantation in Patients Receiving Direct Oral Anticoagulants |
title | Effect of a Novel Pocket Compression Device on Hematomas Following Cardiac Electronic Device Implantation in Patients Receiving Direct Oral Anticoagulants |
title_full | Effect of a Novel Pocket Compression Device on Hematomas Following Cardiac Electronic Device Implantation in Patients Receiving Direct Oral Anticoagulants |
title_fullStr | Effect of a Novel Pocket Compression Device on Hematomas Following Cardiac Electronic Device Implantation in Patients Receiving Direct Oral Anticoagulants |
title_full_unstemmed | Effect of a Novel Pocket Compression Device on Hematomas Following Cardiac Electronic Device Implantation in Patients Receiving Direct Oral Anticoagulants |
title_short | Effect of a Novel Pocket Compression Device on Hematomas Following Cardiac Electronic Device Implantation in Patients Receiving Direct Oral Anticoagulants |
title_sort | effect of a novel pocket compression device on hematomas following cardiac electronic device implantation in patients receiving direct oral anticoagulants |
topic | Cardiovascular Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8907568/ https://www.ncbi.nlm.nih.gov/pubmed/35282349 http://dx.doi.org/10.3389/fcvm.2022.817453 |
work_keys_str_mv | AT feiyeping effectofanovelpocketcompressiondeviceonhematomasfollowingcardiacelectronicdeviceimplantationinpatientsreceivingdirectoralanticoagulants AT wanglei effectofanovelpocketcompressiondeviceonhematomasfollowingcardiacelectronicdeviceimplantationinpatientsreceivingdirectoralanticoagulants AT zhuchunyan effectofanovelpocketcompressiondeviceonhematomasfollowingcardiacelectronicdeviceimplantationinpatientsreceivingdirectoralanticoagulants AT sunjingchao effectofanovelpocketcompressiondeviceonhematomasfollowingcardiacelectronicdeviceimplantationinpatientsreceivingdirectoralanticoagulants AT huhuilin effectofanovelpocketcompressiondeviceonhematomasfollowingcardiacelectronicdeviceimplantationinpatientsreceivingdirectoralanticoagulants AT zhaichanglin effectofanovelpocketcompressiondeviceonhematomasfollowingcardiacelectronicdeviceimplantationinpatientsreceivingdirectoralanticoagulants AT hechaojie effectofanovelpocketcompressiondeviceonhematomasfollowingcardiacelectronicdeviceimplantationinpatientsreceivingdirectoralanticoagulants |