Cargando…

High-Performance Liquid Chromatography–Tandem Mass Spectrometry Analysis of Carbonyl Emissions from E-Cigarette, or Vaping, Products

[Image: see text] A quantitative method was developed to measure four harmful carbonyls (acetaldehyde, acrolein, crotonaldehyde, and formaldehyde) in aerosol generated from e-cigarette, or vaping, products (EVPs). The method uses a commercially available sorbent bed treated with a derivatization sol...

Descripción completa

Detalles Bibliográficos
Autores principales: McGuigan, Megan, Chapman, Gala, Lewis, Erica, Watson, Clifford H., Blount, Benjamin C., Valentin-Blasini, Liza
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2022
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8908497/
https://www.ncbi.nlm.nih.gov/pubmed/35284728
http://dx.doi.org/10.1021/acsomega.1c06321
_version_ 1784665888841007104
author McGuigan, Megan
Chapman, Gala
Lewis, Erica
Watson, Clifford H.
Blount, Benjamin C.
Valentin-Blasini, Liza
author_facet McGuigan, Megan
Chapman, Gala
Lewis, Erica
Watson, Clifford H.
Blount, Benjamin C.
Valentin-Blasini, Liza
author_sort McGuigan, Megan
collection PubMed
description [Image: see text] A quantitative method was developed to measure four harmful carbonyls (acetaldehyde, acrolein, crotonaldehyde, and formaldehyde) in aerosol generated from e-cigarette, or vaping, products (EVPs). The method uses a commercially available sorbent bed treated with a derivatization solution to trap and stabilize reactive carbonyls in aerosol emissions from EVPs to reduce reactive analyte losses and improve quantification. Analytes were extracted from the sorbent material using acetonitrile and analyzed via high-performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS). The method was applied to aerosols generated from products obtained from case patients with EVP use-associated lung injury (EVALI). The method accuracy ranged from 93.6 to 105% in the solvent and 99.0 to 112% in the matrix. Limits of detection (LODs) were in the low nanogram range at 0.735–2.10 ng for all analytes, except formaldehyde at 14.7 ng. Intermediate precision, as determined from the replicate measurements of quality-control (QC) samples, showed a relative standard deviation (RSD) of less than 20% for all analytes. The EVALI case-related products delivered aerosol containing the following ranges of carbonyls: acetaldehyde (0.0856–5.59 μg), acrolein (0.00646–1.05 μg), crotonaldehyde (0.00168–0.108 μg), and formaldehyde (0.0533–12.6 μg). At least one carbonyl analyte was detected in every product. Carbonyl deliveries from EVALI-associated products of all types are consistent with the previously published results for e-cigarettes, and levels are lower than those observed in smoke from combustible cigarettes. This method is rugged, has high throughput, and is well suited for quantifying four harmful carbonyls in aerosol emissions produced by a broad spectrum of devices/solvents, ranging from e-cigarette containing polar solvents to vaping products containing nonpolar solvents.
format Online
Article
Text
id pubmed-8908497
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-89084972022-03-11 High-Performance Liquid Chromatography–Tandem Mass Spectrometry Analysis of Carbonyl Emissions from E-Cigarette, or Vaping, Products McGuigan, Megan Chapman, Gala Lewis, Erica Watson, Clifford H. Blount, Benjamin C. Valentin-Blasini, Liza ACS Omega [Image: see text] A quantitative method was developed to measure four harmful carbonyls (acetaldehyde, acrolein, crotonaldehyde, and formaldehyde) in aerosol generated from e-cigarette, or vaping, products (EVPs). The method uses a commercially available sorbent bed treated with a derivatization solution to trap and stabilize reactive carbonyls in aerosol emissions from EVPs to reduce reactive analyte losses and improve quantification. Analytes were extracted from the sorbent material using acetonitrile and analyzed via high-performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS). The method was applied to aerosols generated from products obtained from case patients with EVP use-associated lung injury (EVALI). The method accuracy ranged from 93.6 to 105% in the solvent and 99.0 to 112% in the matrix. Limits of detection (LODs) were in the low nanogram range at 0.735–2.10 ng for all analytes, except formaldehyde at 14.7 ng. Intermediate precision, as determined from the replicate measurements of quality-control (QC) samples, showed a relative standard deviation (RSD) of less than 20% for all analytes. The EVALI case-related products delivered aerosol containing the following ranges of carbonyls: acetaldehyde (0.0856–5.59 μg), acrolein (0.00646–1.05 μg), crotonaldehyde (0.00168–0.108 μg), and formaldehyde (0.0533–12.6 μg). At least one carbonyl analyte was detected in every product. Carbonyl deliveries from EVALI-associated products of all types are consistent with the previously published results for e-cigarettes, and levels are lower than those observed in smoke from combustible cigarettes. This method is rugged, has high throughput, and is well suited for quantifying four harmful carbonyls in aerosol emissions produced by a broad spectrum of devices/solvents, ranging from e-cigarette containing polar solvents to vaping products containing nonpolar solvents. American Chemical Society 2022-02-21 /pmc/articles/PMC8908497/ /pubmed/35284728 http://dx.doi.org/10.1021/acsomega.1c06321 Text en Not subject to U.S. Copyright. Published 2022 by American Chemical Society https://creativecommons.org/licenses/by-nc-nd/4.0/Permits non-commercial access and re-use, provided that author attribution and integrity are maintained; but does not permit creation of adaptations or other derivative works (https://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle McGuigan, Megan
Chapman, Gala
Lewis, Erica
Watson, Clifford H.
Blount, Benjamin C.
Valentin-Blasini, Liza
High-Performance Liquid Chromatography–Tandem Mass Spectrometry Analysis of Carbonyl Emissions from E-Cigarette, or Vaping, Products
title High-Performance Liquid Chromatography–Tandem Mass Spectrometry Analysis of Carbonyl Emissions from E-Cigarette, or Vaping, Products
title_full High-Performance Liquid Chromatography–Tandem Mass Spectrometry Analysis of Carbonyl Emissions from E-Cigarette, or Vaping, Products
title_fullStr High-Performance Liquid Chromatography–Tandem Mass Spectrometry Analysis of Carbonyl Emissions from E-Cigarette, or Vaping, Products
title_full_unstemmed High-Performance Liquid Chromatography–Tandem Mass Spectrometry Analysis of Carbonyl Emissions from E-Cigarette, or Vaping, Products
title_short High-Performance Liquid Chromatography–Tandem Mass Spectrometry Analysis of Carbonyl Emissions from E-Cigarette, or Vaping, Products
title_sort high-performance liquid chromatography–tandem mass spectrometry analysis of carbonyl emissions from e-cigarette, or vaping, products
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8908497/
https://www.ncbi.nlm.nih.gov/pubmed/35284728
http://dx.doi.org/10.1021/acsomega.1c06321
work_keys_str_mv AT mcguiganmegan highperformanceliquidchromatographytandemmassspectrometryanalysisofcarbonylemissionsfromecigaretteorvapingproducts
AT chapmangala highperformanceliquidchromatographytandemmassspectrometryanalysisofcarbonylemissionsfromecigaretteorvapingproducts
AT lewiserica highperformanceliquidchromatographytandemmassspectrometryanalysisofcarbonylemissionsfromecigaretteorvapingproducts
AT watsoncliffordh highperformanceliquidchromatographytandemmassspectrometryanalysisofcarbonylemissionsfromecigaretteorvapingproducts
AT blountbenjaminc highperformanceliquidchromatographytandemmassspectrometryanalysisofcarbonylemissionsfromecigaretteorvapingproducts
AT valentinblasiniliza highperformanceliquidchromatographytandemmassspectrometryanalysisofcarbonylemissionsfromecigaretteorvapingproducts