Cargando…
High-Performance Liquid Chromatography–Tandem Mass Spectrometry Analysis of Carbonyl Emissions from E-Cigarette, or Vaping, Products
[Image: see text] A quantitative method was developed to measure four harmful carbonyls (acetaldehyde, acrolein, crotonaldehyde, and formaldehyde) in aerosol generated from e-cigarette, or vaping, products (EVPs). The method uses a commercially available sorbent bed treated with a derivatization sol...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Chemical Society
2022
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8908497/ https://www.ncbi.nlm.nih.gov/pubmed/35284728 http://dx.doi.org/10.1021/acsomega.1c06321 |
_version_ | 1784665888841007104 |
---|---|
author | McGuigan, Megan Chapman, Gala Lewis, Erica Watson, Clifford H. Blount, Benjamin C. Valentin-Blasini, Liza |
author_facet | McGuigan, Megan Chapman, Gala Lewis, Erica Watson, Clifford H. Blount, Benjamin C. Valentin-Blasini, Liza |
author_sort | McGuigan, Megan |
collection | PubMed |
description | [Image: see text] A quantitative method was developed to measure four harmful carbonyls (acetaldehyde, acrolein, crotonaldehyde, and formaldehyde) in aerosol generated from e-cigarette, or vaping, products (EVPs). The method uses a commercially available sorbent bed treated with a derivatization solution to trap and stabilize reactive carbonyls in aerosol emissions from EVPs to reduce reactive analyte losses and improve quantification. Analytes were extracted from the sorbent material using acetonitrile and analyzed via high-performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS). The method was applied to aerosols generated from products obtained from case patients with EVP use-associated lung injury (EVALI). The method accuracy ranged from 93.6 to 105% in the solvent and 99.0 to 112% in the matrix. Limits of detection (LODs) were in the low nanogram range at 0.735–2.10 ng for all analytes, except formaldehyde at 14.7 ng. Intermediate precision, as determined from the replicate measurements of quality-control (QC) samples, showed a relative standard deviation (RSD) of less than 20% for all analytes. The EVALI case-related products delivered aerosol containing the following ranges of carbonyls: acetaldehyde (0.0856–5.59 μg), acrolein (0.00646–1.05 μg), crotonaldehyde (0.00168–0.108 μg), and formaldehyde (0.0533–12.6 μg). At least one carbonyl analyte was detected in every product. Carbonyl deliveries from EVALI-associated products of all types are consistent with the previously published results for e-cigarettes, and levels are lower than those observed in smoke from combustible cigarettes. This method is rugged, has high throughput, and is well suited for quantifying four harmful carbonyls in aerosol emissions produced by a broad spectrum of devices/solvents, ranging from e-cigarette containing polar solvents to vaping products containing nonpolar solvents. |
format | Online Article Text |
id | pubmed-8908497 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | American Chemical Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-89084972022-03-11 High-Performance Liquid Chromatography–Tandem Mass Spectrometry Analysis of Carbonyl Emissions from E-Cigarette, or Vaping, Products McGuigan, Megan Chapman, Gala Lewis, Erica Watson, Clifford H. Blount, Benjamin C. Valentin-Blasini, Liza ACS Omega [Image: see text] A quantitative method was developed to measure four harmful carbonyls (acetaldehyde, acrolein, crotonaldehyde, and formaldehyde) in aerosol generated from e-cigarette, or vaping, products (EVPs). The method uses a commercially available sorbent bed treated with a derivatization solution to trap and stabilize reactive carbonyls in aerosol emissions from EVPs to reduce reactive analyte losses and improve quantification. Analytes were extracted from the sorbent material using acetonitrile and analyzed via high-performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS). The method was applied to aerosols generated from products obtained from case patients with EVP use-associated lung injury (EVALI). The method accuracy ranged from 93.6 to 105% in the solvent and 99.0 to 112% in the matrix. Limits of detection (LODs) were in the low nanogram range at 0.735–2.10 ng for all analytes, except formaldehyde at 14.7 ng. Intermediate precision, as determined from the replicate measurements of quality-control (QC) samples, showed a relative standard deviation (RSD) of less than 20% for all analytes. The EVALI case-related products delivered aerosol containing the following ranges of carbonyls: acetaldehyde (0.0856–5.59 μg), acrolein (0.00646–1.05 μg), crotonaldehyde (0.00168–0.108 μg), and formaldehyde (0.0533–12.6 μg). At least one carbonyl analyte was detected in every product. Carbonyl deliveries from EVALI-associated products of all types are consistent with the previously published results for e-cigarettes, and levels are lower than those observed in smoke from combustible cigarettes. This method is rugged, has high throughput, and is well suited for quantifying four harmful carbonyls in aerosol emissions produced by a broad spectrum of devices/solvents, ranging from e-cigarette containing polar solvents to vaping products containing nonpolar solvents. American Chemical Society 2022-02-21 /pmc/articles/PMC8908497/ /pubmed/35284728 http://dx.doi.org/10.1021/acsomega.1c06321 Text en Not subject to U.S. Copyright. Published 2022 by American Chemical Society https://creativecommons.org/licenses/by-nc-nd/4.0/Permits non-commercial access and re-use, provided that author attribution and integrity are maintained; but does not permit creation of adaptations or other derivative works (https://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | McGuigan, Megan Chapman, Gala Lewis, Erica Watson, Clifford H. Blount, Benjamin C. Valentin-Blasini, Liza High-Performance Liquid Chromatography–Tandem Mass Spectrometry Analysis of Carbonyl Emissions from E-Cigarette, or Vaping, Products |
title | High-Performance Liquid Chromatography–Tandem
Mass Spectrometry Analysis of Carbonyl Emissions from E-Cigarette,
or Vaping, Products |
title_full | High-Performance Liquid Chromatography–Tandem
Mass Spectrometry Analysis of Carbonyl Emissions from E-Cigarette,
or Vaping, Products |
title_fullStr | High-Performance Liquid Chromatography–Tandem
Mass Spectrometry Analysis of Carbonyl Emissions from E-Cigarette,
or Vaping, Products |
title_full_unstemmed | High-Performance Liquid Chromatography–Tandem
Mass Spectrometry Analysis of Carbonyl Emissions from E-Cigarette,
or Vaping, Products |
title_short | High-Performance Liquid Chromatography–Tandem
Mass Spectrometry Analysis of Carbonyl Emissions from E-Cigarette,
or Vaping, Products |
title_sort | high-performance liquid chromatography–tandem
mass spectrometry analysis of carbonyl emissions from e-cigarette,
or vaping, products |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8908497/ https://www.ncbi.nlm.nih.gov/pubmed/35284728 http://dx.doi.org/10.1021/acsomega.1c06321 |
work_keys_str_mv | AT mcguiganmegan highperformanceliquidchromatographytandemmassspectrometryanalysisofcarbonylemissionsfromecigaretteorvapingproducts AT chapmangala highperformanceliquidchromatographytandemmassspectrometryanalysisofcarbonylemissionsfromecigaretteorvapingproducts AT lewiserica highperformanceliquidchromatographytandemmassspectrometryanalysisofcarbonylemissionsfromecigaretteorvapingproducts AT watsoncliffordh highperformanceliquidchromatographytandemmassspectrometryanalysisofcarbonylemissionsfromecigaretteorvapingproducts AT blountbenjaminc highperformanceliquidchromatographytandemmassspectrometryanalysisofcarbonylemissionsfromecigaretteorvapingproducts AT valentinblasiniliza highperformanceliquidchromatographytandemmassspectrometryanalysisofcarbonylemissionsfromecigaretteorvapingproducts |