Cargando…

Diagnostic Accuracy of Contrast-Enhanced, Spectral Mammography (CESM) and 3T Magnetic Resonance Compared to Full-Field Digital Mammography plus Ultrasound in Breast Lesions: Results of a (Pilot) Open-Label, Single-Centre Prospective Study

SIMPLE SUMMARY: The characterization of breast lesions by magnetic resonance imaging (MRI) is influenced by a high rate of false positives. Contrast-enhanced spectral mammography (CESM) is a promising modality that seems to compensate for the high costs, times and main limitations of MRI. The aim of...

Descripción completa

Detalles Bibliográficos
Autores principales: Ferranti, Francesca Romana, Vasselli, Federica, Barba, Maddalena, Sperati, Francesca, Terrenato, Irene, Graziano, Franco, Vici, Patrizia, Botti, Claudio, Vidiri, Antonello
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8909837/
https://www.ncbi.nlm.nih.gov/pubmed/35267659
http://dx.doi.org/10.3390/cancers14051351
_version_ 1784666289308958720
author Ferranti, Francesca Romana
Vasselli, Federica
Barba, Maddalena
Sperati, Francesca
Terrenato, Irene
Graziano, Franco
Vici, Patrizia
Botti, Claudio
Vidiri, Antonello
author_facet Ferranti, Francesca Romana
Vasselli, Federica
Barba, Maddalena
Sperati, Francesca
Terrenato, Irene
Graziano, Franco
Vici, Patrizia
Botti, Claudio
Vidiri, Antonello
author_sort Ferranti, Francesca Romana
collection PubMed
description SIMPLE SUMMARY: The characterization of breast lesions by magnetic resonance imaging (MRI) is influenced by a high rate of false positives. Contrast-enhanced spectral mammography (CESM) is a promising modality that seems to compensate for the high costs, times and main limitations of MRI. The aim of our prospective study was to evaluate the diagnostic accuracy of CESM in comparison to 3T MRI imaging in the characterization of breast lesions. We enrolled 118 patients and histologically assessed 142 breast lesions. Patients underwent full-field digital mammography (FFDM), ultrasound (US), with CESM and MRI assessing the diagnostic accuracy of CESM. Sensitivity (Se), specificity (Sp), positive predictive value (PPV) and negative predictive value (NPV) were considered as measures of accuracy of different diagnostic procedures in predicting the nature and characteristics of the examined breast lesions. ABSTRACT: Introduction: To assess the diagnostic accuracy of CESM and 3T MRI compared to full-field digital mammography (FFDM), plus US, in the evaluation of advanced breast lesions. Materials and Methods: Consenting women with suspicious findings underwent FFDM, US, CESM and 3T MRI. Breast lesions were histologically assessed, with histology being the gold standard. Two experienced breast radiologists, blinded to cancer status, read the images. Diagnostic accuracy of (1) CESM as an adjunct to FFDM and US, and (2) 3T MRI as an adjunct to CESM compared to FFDM and US, was assessed. Measures of accuracy were sensitivity (Se), specificity (Sp), positive predictive value (PPV) and negative predictive value (NPV). Results: There were 118 patients included along with 142 histologically characterized lesions. K agreement values were 0.69, 0.68, 0.63 and 0.56 for concordance between the gold standard and FFDM, FFDM + US, CESM and MRI, respectively (p < 0.001, for all). K concordance for CESM was 0.81 with FFDM + US and 0.73 with MRI (p value < 0.001 for all). Conclusions: CESM may represent a valuable alternative and/or an integrating technique to MRI in the evaluation of breast cancer patients.
format Online
Article
Text
id pubmed-8909837
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-89098372022-03-11 Diagnostic Accuracy of Contrast-Enhanced, Spectral Mammography (CESM) and 3T Magnetic Resonance Compared to Full-Field Digital Mammography plus Ultrasound in Breast Lesions: Results of a (Pilot) Open-Label, Single-Centre Prospective Study Ferranti, Francesca Romana Vasselli, Federica Barba, Maddalena Sperati, Francesca Terrenato, Irene Graziano, Franco Vici, Patrizia Botti, Claudio Vidiri, Antonello Cancers (Basel) Article SIMPLE SUMMARY: The characterization of breast lesions by magnetic resonance imaging (MRI) is influenced by a high rate of false positives. Contrast-enhanced spectral mammography (CESM) is a promising modality that seems to compensate for the high costs, times and main limitations of MRI. The aim of our prospective study was to evaluate the diagnostic accuracy of CESM in comparison to 3T MRI imaging in the characterization of breast lesions. We enrolled 118 patients and histologically assessed 142 breast lesions. Patients underwent full-field digital mammography (FFDM), ultrasound (US), with CESM and MRI assessing the diagnostic accuracy of CESM. Sensitivity (Se), specificity (Sp), positive predictive value (PPV) and negative predictive value (NPV) were considered as measures of accuracy of different diagnostic procedures in predicting the nature and characteristics of the examined breast lesions. ABSTRACT: Introduction: To assess the diagnostic accuracy of CESM and 3T MRI compared to full-field digital mammography (FFDM), plus US, in the evaluation of advanced breast lesions. Materials and Methods: Consenting women with suspicious findings underwent FFDM, US, CESM and 3T MRI. Breast lesions were histologically assessed, with histology being the gold standard. Two experienced breast radiologists, blinded to cancer status, read the images. Diagnostic accuracy of (1) CESM as an adjunct to FFDM and US, and (2) 3T MRI as an adjunct to CESM compared to FFDM and US, was assessed. Measures of accuracy were sensitivity (Se), specificity (Sp), positive predictive value (PPV) and negative predictive value (NPV). Results: There were 118 patients included along with 142 histologically characterized lesions. K agreement values were 0.69, 0.68, 0.63 and 0.56 for concordance between the gold standard and FFDM, FFDM + US, CESM and MRI, respectively (p < 0.001, for all). K concordance for CESM was 0.81 with FFDM + US and 0.73 with MRI (p value < 0.001 for all). Conclusions: CESM may represent a valuable alternative and/or an integrating technique to MRI in the evaluation of breast cancer patients. MDPI 2022-03-07 /pmc/articles/PMC8909837/ /pubmed/35267659 http://dx.doi.org/10.3390/cancers14051351 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ferranti, Francesca Romana
Vasselli, Federica
Barba, Maddalena
Sperati, Francesca
Terrenato, Irene
Graziano, Franco
Vici, Patrizia
Botti, Claudio
Vidiri, Antonello
Diagnostic Accuracy of Contrast-Enhanced, Spectral Mammography (CESM) and 3T Magnetic Resonance Compared to Full-Field Digital Mammography plus Ultrasound in Breast Lesions: Results of a (Pilot) Open-Label, Single-Centre Prospective Study
title Diagnostic Accuracy of Contrast-Enhanced, Spectral Mammography (CESM) and 3T Magnetic Resonance Compared to Full-Field Digital Mammography plus Ultrasound in Breast Lesions: Results of a (Pilot) Open-Label, Single-Centre Prospective Study
title_full Diagnostic Accuracy of Contrast-Enhanced, Spectral Mammography (CESM) and 3T Magnetic Resonance Compared to Full-Field Digital Mammography plus Ultrasound in Breast Lesions: Results of a (Pilot) Open-Label, Single-Centre Prospective Study
title_fullStr Diagnostic Accuracy of Contrast-Enhanced, Spectral Mammography (CESM) and 3T Magnetic Resonance Compared to Full-Field Digital Mammography plus Ultrasound in Breast Lesions: Results of a (Pilot) Open-Label, Single-Centre Prospective Study
title_full_unstemmed Diagnostic Accuracy of Contrast-Enhanced, Spectral Mammography (CESM) and 3T Magnetic Resonance Compared to Full-Field Digital Mammography plus Ultrasound in Breast Lesions: Results of a (Pilot) Open-Label, Single-Centre Prospective Study
title_short Diagnostic Accuracy of Contrast-Enhanced, Spectral Mammography (CESM) and 3T Magnetic Resonance Compared to Full-Field Digital Mammography plus Ultrasound in Breast Lesions: Results of a (Pilot) Open-Label, Single-Centre Prospective Study
title_sort diagnostic accuracy of contrast-enhanced, spectral mammography (cesm) and 3t magnetic resonance compared to full-field digital mammography plus ultrasound in breast lesions: results of a (pilot) open-label, single-centre prospective study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8909837/
https://www.ncbi.nlm.nih.gov/pubmed/35267659
http://dx.doi.org/10.3390/cancers14051351
work_keys_str_mv AT ferrantifrancescaromana diagnosticaccuracyofcontrastenhancedspectralmammographycesmand3tmagneticresonancecomparedtofullfielddigitalmammographyplusultrasoundinbreastlesionsresultsofapilotopenlabelsinglecentreprospectivestudy
AT vassellifederica diagnosticaccuracyofcontrastenhancedspectralmammographycesmand3tmagneticresonancecomparedtofullfielddigitalmammographyplusultrasoundinbreastlesionsresultsofapilotopenlabelsinglecentreprospectivestudy
AT barbamaddalena diagnosticaccuracyofcontrastenhancedspectralmammographycesmand3tmagneticresonancecomparedtofullfielddigitalmammographyplusultrasoundinbreastlesionsresultsofapilotopenlabelsinglecentreprospectivestudy
AT speratifrancesca diagnosticaccuracyofcontrastenhancedspectralmammographycesmand3tmagneticresonancecomparedtofullfielddigitalmammographyplusultrasoundinbreastlesionsresultsofapilotopenlabelsinglecentreprospectivestudy
AT terrenatoirene diagnosticaccuracyofcontrastenhancedspectralmammographycesmand3tmagneticresonancecomparedtofullfielddigitalmammographyplusultrasoundinbreastlesionsresultsofapilotopenlabelsinglecentreprospectivestudy
AT grazianofranco diagnosticaccuracyofcontrastenhancedspectralmammographycesmand3tmagneticresonancecomparedtofullfielddigitalmammographyplusultrasoundinbreastlesionsresultsofapilotopenlabelsinglecentreprospectivestudy
AT vicipatrizia diagnosticaccuracyofcontrastenhancedspectralmammographycesmand3tmagneticresonancecomparedtofullfielddigitalmammographyplusultrasoundinbreastlesionsresultsofapilotopenlabelsinglecentreprospectivestudy
AT botticlaudio diagnosticaccuracyofcontrastenhancedspectralmammographycesmand3tmagneticresonancecomparedtofullfielddigitalmammographyplusultrasoundinbreastlesionsresultsofapilotopenlabelsinglecentreprospectivestudy
AT vidiriantonello diagnosticaccuracyofcontrastenhancedspectralmammographycesmand3tmagneticresonancecomparedtofullfielddigitalmammographyplusultrasoundinbreastlesionsresultsofapilotopenlabelsinglecentreprospectivestudy