Cargando…

The Seismic Performance of New Self-Centering Beam-Column Joints of Conventional Island Main Buildings in Nuclear Power Plants

In order to improve the deformation energy consumption and self-centering ability of reinforced concrete (RC) frame beam-column joints for main buildings of conventional islands in nuclear power plants, a new type of self-centering joint equipped with super-elastic shape memory alloy (SMA) bars and...

Descripción completa

Detalles Bibliográficos
Autores principales: Pei, Qiang, Wu, Cong, Cheng, Zhi, Ding, Yu, Guo, Hang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8911000/
https://www.ncbi.nlm.nih.gov/pubmed/35268934
http://dx.doi.org/10.3390/ma15051704
_version_ 1784666664043806720
author Pei, Qiang
Wu, Cong
Cheng, Zhi
Ding, Yu
Guo, Hang
author_facet Pei, Qiang
Wu, Cong
Cheng, Zhi
Ding, Yu
Guo, Hang
author_sort Pei, Qiang
collection PubMed
description In order to improve the deformation energy consumption and self-centering ability of reinforced concrete (RC) frame beam-column joints for main buildings of conventional islands in nuclear power plants, a new type of self-centering joint equipped with super-elastic shape memory alloy (SMA) bars and a steel plate as kernel components in the core area of the joint is proposed in this study. Four 1/5-scale frame joints were designed and manufactured, including two contrast joints (a normal reinforced concrete joint and a concrete joint that replaces steel bars with SMA bars) and two new model joints with different SMA reinforcement ratios. Subsequently, the residual deformation, energy dissipation capacity, stiffness degradation and self-centering performance of the novel frame joints were studied through a low-frequency cyclic loading test. Finally, based on the OpenSees finite element software platform, an effective numerical model of the new joint was established and verified. On this basis, varying two main parameters, the SMA reinforcement ratio and the axial compression ratio, a simulation was systematically conducted to demonstrate the effectiveness of the proposed joint in seismic performance. The results show that replacing ordinary steel bars in the beam with SMA bars not only greatly reduces the bearing capacity and stiffness of the joint, but also makes the failure mode of the joint brittle. The construction of a new type of joint with consideration of the SMA reinforcement and the steel plate can improve the bearing capacity, delay the stiffness degradation and improve the ductility and self-centering capability of the joints. Within a certain range, increasing the ratio of the SMA bars can further improve the ultimate bearing capacity and energy dissipation capacity of the new joint. Increasing or decreasing the axial compression ratio of column ends has little effect on the overall seismic performance of new joints.
format Online
Article
Text
id pubmed-8911000
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-89110002022-03-11 The Seismic Performance of New Self-Centering Beam-Column Joints of Conventional Island Main Buildings in Nuclear Power Plants Pei, Qiang Wu, Cong Cheng, Zhi Ding, Yu Guo, Hang Materials (Basel) Article In order to improve the deformation energy consumption and self-centering ability of reinforced concrete (RC) frame beam-column joints for main buildings of conventional islands in nuclear power plants, a new type of self-centering joint equipped with super-elastic shape memory alloy (SMA) bars and a steel plate as kernel components in the core area of the joint is proposed in this study. Four 1/5-scale frame joints were designed and manufactured, including two contrast joints (a normal reinforced concrete joint and a concrete joint that replaces steel bars with SMA bars) and two new model joints with different SMA reinforcement ratios. Subsequently, the residual deformation, energy dissipation capacity, stiffness degradation and self-centering performance of the novel frame joints were studied through a low-frequency cyclic loading test. Finally, based on the OpenSees finite element software platform, an effective numerical model of the new joint was established and verified. On this basis, varying two main parameters, the SMA reinforcement ratio and the axial compression ratio, a simulation was systematically conducted to demonstrate the effectiveness of the proposed joint in seismic performance. The results show that replacing ordinary steel bars in the beam with SMA bars not only greatly reduces the bearing capacity and stiffness of the joint, but also makes the failure mode of the joint brittle. The construction of a new type of joint with consideration of the SMA reinforcement and the steel plate can improve the bearing capacity, delay the stiffness degradation and improve the ductility and self-centering capability of the joints. Within a certain range, increasing the ratio of the SMA bars can further improve the ultimate bearing capacity and energy dissipation capacity of the new joint. Increasing or decreasing the axial compression ratio of column ends has little effect on the overall seismic performance of new joints. MDPI 2022-02-24 /pmc/articles/PMC8911000/ /pubmed/35268934 http://dx.doi.org/10.3390/ma15051704 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Pei, Qiang
Wu, Cong
Cheng, Zhi
Ding, Yu
Guo, Hang
The Seismic Performance of New Self-Centering Beam-Column Joints of Conventional Island Main Buildings in Nuclear Power Plants
title The Seismic Performance of New Self-Centering Beam-Column Joints of Conventional Island Main Buildings in Nuclear Power Plants
title_full The Seismic Performance of New Self-Centering Beam-Column Joints of Conventional Island Main Buildings in Nuclear Power Plants
title_fullStr The Seismic Performance of New Self-Centering Beam-Column Joints of Conventional Island Main Buildings in Nuclear Power Plants
title_full_unstemmed The Seismic Performance of New Self-Centering Beam-Column Joints of Conventional Island Main Buildings in Nuclear Power Plants
title_short The Seismic Performance of New Self-Centering Beam-Column Joints of Conventional Island Main Buildings in Nuclear Power Plants
title_sort seismic performance of new self-centering beam-column joints of conventional island main buildings in nuclear power plants
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8911000/
https://www.ncbi.nlm.nih.gov/pubmed/35268934
http://dx.doi.org/10.3390/ma15051704
work_keys_str_mv AT peiqiang theseismicperformanceofnewselfcenteringbeamcolumnjointsofconventionalislandmainbuildingsinnuclearpowerplants
AT wucong theseismicperformanceofnewselfcenteringbeamcolumnjointsofconventionalislandmainbuildingsinnuclearpowerplants
AT chengzhi theseismicperformanceofnewselfcenteringbeamcolumnjointsofconventionalislandmainbuildingsinnuclearpowerplants
AT dingyu theseismicperformanceofnewselfcenteringbeamcolumnjointsofconventionalislandmainbuildingsinnuclearpowerplants
AT guohang theseismicperformanceofnewselfcenteringbeamcolumnjointsofconventionalislandmainbuildingsinnuclearpowerplants
AT peiqiang seismicperformanceofnewselfcenteringbeamcolumnjointsofconventionalislandmainbuildingsinnuclearpowerplants
AT wucong seismicperformanceofnewselfcenteringbeamcolumnjointsofconventionalislandmainbuildingsinnuclearpowerplants
AT chengzhi seismicperformanceofnewselfcenteringbeamcolumnjointsofconventionalislandmainbuildingsinnuclearpowerplants
AT dingyu seismicperformanceofnewselfcenteringbeamcolumnjointsofconventionalislandmainbuildingsinnuclearpowerplants
AT guohang seismicperformanceofnewselfcenteringbeamcolumnjointsofconventionalislandmainbuildingsinnuclearpowerplants