LOQTEQ(®) VA Periprosthetic Plate—A New Concept for Bicortical Screw Fixation in Periprosthetic Fractures: A Technical Note

Internal fixation using angle stable plates is the treatment standard in periprosthetic fractures around stable implants. To provide instant postoperative full weight-bearing, bicortical screw fixation is advisable but often surgically demanding. This work presents the first clinical results of the...

Descripción completa

Detalles Bibliográficos
Autores principales: Kösters, Clemens, den Toom, Daniel, Märdian, Sven, Roßlenbroich, Steffen, Metzlaff, Sebastian, Daniilidis, Kiriakos, Everding, Jens
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8911225/
https://www.ncbi.nlm.nih.gov/pubmed/35268275
http://dx.doi.org/10.3390/jcm11051184
_version_ 1784666738878578688
author Kösters, Clemens
den Toom, Daniel
Märdian, Sven
Roßlenbroich, Steffen
Metzlaff, Sebastian
Daniilidis, Kiriakos
Everding, Jens
author_facet Kösters, Clemens
den Toom, Daniel
Märdian, Sven
Roßlenbroich, Steffen
Metzlaff, Sebastian
Daniilidis, Kiriakos
Everding, Jens
author_sort Kösters, Clemens
collection PubMed
description Internal fixation using angle stable plates is the treatment standard in periprosthetic fractures around stable implants. To provide instant postoperative full weight-bearing, bicortical screw fixation is advisable but often surgically demanding. This work presents the first clinical results of the LOQTEQ(®) VA Periprosthetic Plate (aap Implantate AG, Berlin, Germany), a new plate system to simplify screw placement around implants. This plate system uses insertable hinges that allow for variable angle screw anchorage. Data of 26 patients with a mean age of 80 years and a mean follow-up of 13.9 months were retrospectively collected. Patients were clinically and radiologically examined. Bony union was achieved in 14 out of 15 patients with no signs of non-union or implant loosening. One patient, however, presented with implant failure. Clinical scores demonstrated acceptable results. Since the hinge plates are easy to apply, the first results are promising.
format Online
Article
Text
id pubmed-8911225
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-89112252022-03-11 LOQTEQ(®) VA Periprosthetic Plate—A New Concept for Bicortical Screw Fixation in Periprosthetic Fractures: A Technical Note Kösters, Clemens den Toom, Daniel Märdian, Sven Roßlenbroich, Steffen Metzlaff, Sebastian Daniilidis, Kiriakos Everding, Jens J Clin Med Article Internal fixation using angle stable plates is the treatment standard in periprosthetic fractures around stable implants. To provide instant postoperative full weight-bearing, bicortical screw fixation is advisable but often surgically demanding. This work presents the first clinical results of the LOQTEQ(®) VA Periprosthetic Plate (aap Implantate AG, Berlin, Germany), a new plate system to simplify screw placement around implants. This plate system uses insertable hinges that allow for variable angle screw anchorage. Data of 26 patients with a mean age of 80 years and a mean follow-up of 13.9 months were retrospectively collected. Patients were clinically and radiologically examined. Bony union was achieved in 14 out of 15 patients with no signs of non-union or implant loosening. One patient, however, presented with implant failure. Clinical scores demonstrated acceptable results. Since the hinge plates are easy to apply, the first results are promising. MDPI 2022-02-23 /pmc/articles/PMC8911225/ /pubmed/35268275 http://dx.doi.org/10.3390/jcm11051184 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kösters, Clemens
den Toom, Daniel
Märdian, Sven
Roßlenbroich, Steffen
Metzlaff, Sebastian
Daniilidis, Kiriakos
Everding, Jens
LOQTEQ(®) VA Periprosthetic Plate—A New Concept for Bicortical Screw Fixation in Periprosthetic Fractures: A Technical Note
title LOQTEQ(®) VA Periprosthetic Plate—A New Concept for Bicortical Screw Fixation in Periprosthetic Fractures: A Technical Note
title_full LOQTEQ(®) VA Periprosthetic Plate—A New Concept for Bicortical Screw Fixation in Periprosthetic Fractures: A Technical Note
title_fullStr LOQTEQ(®) VA Periprosthetic Plate—A New Concept for Bicortical Screw Fixation in Periprosthetic Fractures: A Technical Note
title_full_unstemmed LOQTEQ(®) VA Periprosthetic Plate—A New Concept for Bicortical Screw Fixation in Periprosthetic Fractures: A Technical Note
title_short LOQTEQ(®) VA Periprosthetic Plate—A New Concept for Bicortical Screw Fixation in Periprosthetic Fractures: A Technical Note
title_sort loqteq(®) va periprosthetic plate—a new concept for bicortical screw fixation in periprosthetic fractures: a technical note
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8911225/
https://www.ncbi.nlm.nih.gov/pubmed/35268275
http://dx.doi.org/10.3390/jcm11051184
work_keys_str_mv AT kostersclemens loqteqvaperiprostheticplateanewconceptforbicorticalscrewfixationinperiprostheticfracturesatechnicalnote
AT dentoomdaniel loqteqvaperiprostheticplateanewconceptforbicorticalscrewfixationinperiprostheticfracturesatechnicalnote
AT mardiansven loqteqvaperiprostheticplateanewconceptforbicorticalscrewfixationinperiprostheticfracturesatechnicalnote
AT roßlenbroichsteffen loqteqvaperiprostheticplateanewconceptforbicorticalscrewfixationinperiprostheticfracturesatechnicalnote
AT metzlaffsebastian loqteqvaperiprostheticplateanewconceptforbicorticalscrewfixationinperiprostheticfracturesatechnicalnote
AT daniilidiskiriakos loqteqvaperiprostheticplateanewconceptforbicorticalscrewfixationinperiprostheticfracturesatechnicalnote
AT everdingjens loqteqvaperiprostheticplateanewconceptforbicorticalscrewfixationinperiprostheticfracturesatechnicalnote