Cargando…
Evaluation on the Performance of Hydraulic Bitumen Binders under High and Low Temperatures for Pumped Storage Power Station Projects
The high and low-temperature performance of five hydraulic bitumen binders was evaluated using the dynamic shear rheometer (DSR) test, infrared spectrum test and direct tensile (DT) test. These hydraulic bitumen binders were respectively applied for several pumped storage power stations (PSPS) proje...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8911587/ https://www.ncbi.nlm.nih.gov/pubmed/35269120 http://dx.doi.org/10.3390/ma15051890 |
_version_ | 1784666852895490048 |
---|---|
author | Zou, Changgen Hua, Zhao Mo, Liantong Qi, Cong Liu, Zhixin Xie, Yanjun Yu, Hao Ke, Juntao |
author_facet | Zou, Changgen Hua, Zhao Mo, Liantong Qi, Cong Liu, Zhixin Xie, Yanjun Yu, Hao Ke, Juntao |
author_sort | Zou, Changgen |
collection | PubMed |
description | The high and low-temperature performance of five hydraulic bitumen binders was evaluated using the dynamic shear rheometer (DSR) test, infrared spectrum test and direct tensile (DT) test. These hydraulic bitumen binders were respectively applied for several pumped storage power stations (PSPS) projects that were constructed or under construction. In order to relate the bitumen performance to the mixture performance, the slope flow test, three-point bending test and thermal stress restrained specimen test were carried out on hydraulic asphalt mixtures. The test results indicated the DSR rheological master curves can well distinguish the difference of each bitumen binder as well as the effect of polymer modification. Phase angle master curves, black diagrams and infrared spectra all indicated that several penetration-grade hydraulic bitumen binders were not virgin bitumen binders but were modified with relatively lower SBS polymer content when compared with traditional SBS-modified bitumen. When selecting the commonly used Karamay SG70 hydraulic bitumen as a reference, the normal SBS-modified bitumen was superior to other bitumen in terms of low- and high-temperature performance. Several slightly SBS-modified bitumen binders did not always show consistent results, which indicated that slightly modified bitumen may not really have the desired performance as expected. Therefore, SBS-modified bitumen will be more promising when dealing with extremely low or high temperatures. Bitumen performance was well compared with the mixture performance by using the bitumen creep, relaxation and tensile failure strain corresponding to the asphalt concrete slope flow, the maximum bending strain and the failure temperature, respectively. Compared with the traditional penetration, softening point and ductility test, it indicated that the DSR rheological test, creep test, direct tensile test and stress relaxation test can be used as more powerful tools for the characterization and optimization of hydraulic bitumen binders. |
format | Online Article Text |
id | pubmed-8911587 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-89115872022-03-11 Evaluation on the Performance of Hydraulic Bitumen Binders under High and Low Temperatures for Pumped Storage Power Station Projects Zou, Changgen Hua, Zhao Mo, Liantong Qi, Cong Liu, Zhixin Xie, Yanjun Yu, Hao Ke, Juntao Materials (Basel) Article The high and low-temperature performance of five hydraulic bitumen binders was evaluated using the dynamic shear rheometer (DSR) test, infrared spectrum test and direct tensile (DT) test. These hydraulic bitumen binders were respectively applied for several pumped storage power stations (PSPS) projects that were constructed or under construction. In order to relate the bitumen performance to the mixture performance, the slope flow test, three-point bending test and thermal stress restrained specimen test were carried out on hydraulic asphalt mixtures. The test results indicated the DSR rheological master curves can well distinguish the difference of each bitumen binder as well as the effect of polymer modification. Phase angle master curves, black diagrams and infrared spectra all indicated that several penetration-grade hydraulic bitumen binders were not virgin bitumen binders but were modified with relatively lower SBS polymer content when compared with traditional SBS-modified bitumen. When selecting the commonly used Karamay SG70 hydraulic bitumen as a reference, the normal SBS-modified bitumen was superior to other bitumen in terms of low- and high-temperature performance. Several slightly SBS-modified bitumen binders did not always show consistent results, which indicated that slightly modified bitumen may not really have the desired performance as expected. Therefore, SBS-modified bitumen will be more promising when dealing with extremely low or high temperatures. Bitumen performance was well compared with the mixture performance by using the bitumen creep, relaxation and tensile failure strain corresponding to the asphalt concrete slope flow, the maximum bending strain and the failure temperature, respectively. Compared with the traditional penetration, softening point and ductility test, it indicated that the DSR rheological test, creep test, direct tensile test and stress relaxation test can be used as more powerful tools for the characterization and optimization of hydraulic bitumen binders. MDPI 2022-03-03 /pmc/articles/PMC8911587/ /pubmed/35269120 http://dx.doi.org/10.3390/ma15051890 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Zou, Changgen Hua, Zhao Mo, Liantong Qi, Cong Liu, Zhixin Xie, Yanjun Yu, Hao Ke, Juntao Evaluation on the Performance of Hydraulic Bitumen Binders under High and Low Temperatures for Pumped Storage Power Station Projects |
title | Evaluation on the Performance of Hydraulic Bitumen Binders under High and Low Temperatures for Pumped Storage Power Station Projects |
title_full | Evaluation on the Performance of Hydraulic Bitumen Binders under High and Low Temperatures for Pumped Storage Power Station Projects |
title_fullStr | Evaluation on the Performance of Hydraulic Bitumen Binders under High and Low Temperatures for Pumped Storage Power Station Projects |
title_full_unstemmed | Evaluation on the Performance of Hydraulic Bitumen Binders under High and Low Temperatures for Pumped Storage Power Station Projects |
title_short | Evaluation on the Performance of Hydraulic Bitumen Binders under High and Low Temperatures for Pumped Storage Power Station Projects |
title_sort | evaluation on the performance of hydraulic bitumen binders under high and low temperatures for pumped storage power station projects |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8911587/ https://www.ncbi.nlm.nih.gov/pubmed/35269120 http://dx.doi.org/10.3390/ma15051890 |
work_keys_str_mv | AT zouchanggen evaluationontheperformanceofhydraulicbitumenbindersunderhighandlowtemperaturesforpumpedstoragepowerstationprojects AT huazhao evaluationontheperformanceofhydraulicbitumenbindersunderhighandlowtemperaturesforpumpedstoragepowerstationprojects AT moliantong evaluationontheperformanceofhydraulicbitumenbindersunderhighandlowtemperaturesforpumpedstoragepowerstationprojects AT qicong evaluationontheperformanceofhydraulicbitumenbindersunderhighandlowtemperaturesforpumpedstoragepowerstationprojects AT liuzhixin evaluationontheperformanceofhydraulicbitumenbindersunderhighandlowtemperaturesforpumpedstoragepowerstationprojects AT xieyanjun evaluationontheperformanceofhydraulicbitumenbindersunderhighandlowtemperaturesforpumpedstoragepowerstationprojects AT yuhao evaluationontheperformanceofhydraulicbitumenbindersunderhighandlowtemperaturesforpumpedstoragepowerstationprojects AT kejuntao evaluationontheperformanceofhydraulicbitumenbindersunderhighandlowtemperaturesforpumpedstoragepowerstationprojects |