Cargando…
A Multi-Attribute Decision-Making Model for the Selection of Polymer-Based Biomaterial for Orthopedic Industrial Applications
The potential of quantifying the variations in IR active bands was explored while using the chemometric analysis of FTIR spectra for selecting orthopedic biomaterial of industrial scale i.e., ultra-high molecular weight PE (UHMWPE). The nano composites UHMWPE with multi-walled carbon nano-tubes (MWC...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8912859/ https://www.ncbi.nlm.nih.gov/pubmed/35267842 http://dx.doi.org/10.3390/polym14051020 |
_version_ | 1784667267186819072 |
---|---|
author | Rizwan, Ali Abualsauod, Emad H. Othman, Asem Majed Serbaya, Suhail H. Shahzad, Muhammad Atif Hameed, Abdul Zubar |
author_facet | Rizwan, Ali Abualsauod, Emad H. Othman, Asem Majed Serbaya, Suhail H. Shahzad, Muhammad Atif Hameed, Abdul Zubar |
author_sort | Rizwan, Ali |
collection | PubMed |
description | The potential of quantifying the variations in IR active bands was explored while using the chemometric analysis of FTIR spectra for selecting orthopedic biomaterial of industrial scale i.e., ultra-high molecular weight PE (UHMWPE). The nano composites UHMWPE with multi-walled carbon nano-tubes (MWCNTs) and Mg-silicate were prepared and irradiated with 25 kGy and 50 kGy of gamma dose. Principal component analysis (PCA) revealed that first three principal components (PCs) are responsible for explaining the >99% of variance in FTIR data of UHMWPE on addition of fillers and/or irradiation. The factor loadings plots revealed that PC-1 was responsible for explaining the variance in polyethylene characteristics bands and the IR active region induced by fillers i.e., 440 cm(−1), 456 cm(−1), from 900–1200 cm(−1), 1210 cm(−1), 1596 cm(−1), PC-2 was responsible for explaining the variance in spectra due to radiation-induced oxidation and cross linking, while the PC-3 is responsible for explaining the variance induced because of IR active bands of MWCNTs. Hierarchy cluster analysis (HCA) was employed to classify the samples into four clusters with respect to similarity in their IR active bands which is further confirmed by PCA. According to multi attribute analysis with PCA and HCA, 65 kGy irradiated sample is optimum choice from the existing alternatives in the group of irradiated pristine UHMWPE, UHMWPE/Mg-silicate irradiated with 25 kGy of gamma dose was the optimum choice for UHWMPE/Mg-silicate nano composites, and UHMWPE/γMWCNTs composites containing 1.0% dof γ MWCNTs for UHMWPE/MWCNTs nanocomposites, respectively. The results show the effectiveness of quantifying the variance for decision as far as optimization of biomaterials in orthopedic industrial applications is concerned. |
format | Online Article Text |
id | pubmed-8912859 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-89128592022-03-11 A Multi-Attribute Decision-Making Model for the Selection of Polymer-Based Biomaterial for Orthopedic Industrial Applications Rizwan, Ali Abualsauod, Emad H. Othman, Asem Majed Serbaya, Suhail H. Shahzad, Muhammad Atif Hameed, Abdul Zubar Polymers (Basel) Article The potential of quantifying the variations in IR active bands was explored while using the chemometric analysis of FTIR spectra for selecting orthopedic biomaterial of industrial scale i.e., ultra-high molecular weight PE (UHMWPE). The nano composites UHMWPE with multi-walled carbon nano-tubes (MWCNTs) and Mg-silicate were prepared and irradiated with 25 kGy and 50 kGy of gamma dose. Principal component analysis (PCA) revealed that first three principal components (PCs) are responsible for explaining the >99% of variance in FTIR data of UHMWPE on addition of fillers and/or irradiation. The factor loadings plots revealed that PC-1 was responsible for explaining the variance in polyethylene characteristics bands and the IR active region induced by fillers i.e., 440 cm(−1), 456 cm(−1), from 900–1200 cm(−1), 1210 cm(−1), 1596 cm(−1), PC-2 was responsible for explaining the variance in spectra due to radiation-induced oxidation and cross linking, while the PC-3 is responsible for explaining the variance induced because of IR active bands of MWCNTs. Hierarchy cluster analysis (HCA) was employed to classify the samples into four clusters with respect to similarity in their IR active bands which is further confirmed by PCA. According to multi attribute analysis with PCA and HCA, 65 kGy irradiated sample is optimum choice from the existing alternatives in the group of irradiated pristine UHMWPE, UHMWPE/Mg-silicate irradiated with 25 kGy of gamma dose was the optimum choice for UHWMPE/Mg-silicate nano composites, and UHMWPE/γMWCNTs composites containing 1.0% dof γ MWCNTs for UHMWPE/MWCNTs nanocomposites, respectively. The results show the effectiveness of quantifying the variance for decision as far as optimization of biomaterials in orthopedic industrial applications is concerned. MDPI 2022-03-03 /pmc/articles/PMC8912859/ /pubmed/35267842 http://dx.doi.org/10.3390/polym14051020 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Rizwan, Ali Abualsauod, Emad H. Othman, Asem Majed Serbaya, Suhail H. Shahzad, Muhammad Atif Hameed, Abdul Zubar A Multi-Attribute Decision-Making Model for the Selection of Polymer-Based Biomaterial for Orthopedic Industrial Applications |
title | A Multi-Attribute Decision-Making Model for the Selection of Polymer-Based Biomaterial for Orthopedic Industrial Applications |
title_full | A Multi-Attribute Decision-Making Model for the Selection of Polymer-Based Biomaterial for Orthopedic Industrial Applications |
title_fullStr | A Multi-Attribute Decision-Making Model for the Selection of Polymer-Based Biomaterial for Orthopedic Industrial Applications |
title_full_unstemmed | A Multi-Attribute Decision-Making Model for the Selection of Polymer-Based Biomaterial for Orthopedic Industrial Applications |
title_short | A Multi-Attribute Decision-Making Model for the Selection of Polymer-Based Biomaterial for Orthopedic Industrial Applications |
title_sort | multi-attribute decision-making model for the selection of polymer-based biomaterial for orthopedic industrial applications |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8912859/ https://www.ncbi.nlm.nih.gov/pubmed/35267842 http://dx.doi.org/10.3390/polym14051020 |
work_keys_str_mv | AT rizwanali amultiattributedecisionmakingmodelfortheselectionofpolymerbasedbiomaterialfororthopedicindustrialapplications AT abualsauodemadh amultiattributedecisionmakingmodelfortheselectionofpolymerbasedbiomaterialfororthopedicindustrialapplications AT othmanasemmajed amultiattributedecisionmakingmodelfortheselectionofpolymerbasedbiomaterialfororthopedicindustrialapplications AT serbayasuhailh amultiattributedecisionmakingmodelfortheselectionofpolymerbasedbiomaterialfororthopedicindustrialapplications AT shahzadmuhammadatif amultiattributedecisionmakingmodelfortheselectionofpolymerbasedbiomaterialfororthopedicindustrialapplications AT hameedabdulzubar amultiattributedecisionmakingmodelfortheselectionofpolymerbasedbiomaterialfororthopedicindustrialapplications AT rizwanali multiattributedecisionmakingmodelfortheselectionofpolymerbasedbiomaterialfororthopedicindustrialapplications AT abualsauodemadh multiattributedecisionmakingmodelfortheselectionofpolymerbasedbiomaterialfororthopedicindustrialapplications AT othmanasemmajed multiattributedecisionmakingmodelfortheselectionofpolymerbasedbiomaterialfororthopedicindustrialapplications AT serbayasuhailh multiattributedecisionmakingmodelfortheselectionofpolymerbasedbiomaterialfororthopedicindustrialapplications AT shahzadmuhammadatif multiattributedecisionmakingmodelfortheselectionofpolymerbasedbiomaterialfororthopedicindustrialapplications AT hameedabdulzubar multiattributedecisionmakingmodelfortheselectionofpolymerbasedbiomaterialfororthopedicindustrialapplications |