Cargando…

Ultrasound Evaluation of the Diaphragm in Clinical Anesthesia

When the human body is anesthetized, the human nerve tissue will be greatly affected, which also affects the breathing of the human body. The respiration during anesthesia is a lack of initiative, and the energy efficiency of the diaphragm in the lungs is very important to the safety of anesthesia....

Descripción completa

Detalles Bibliográficos
Autores principales: He, Yina, Zhao, Tiantian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8913060/
https://www.ncbi.nlm.nih.gov/pubmed/35281531
http://dx.doi.org/10.1155/2022/2163225
_version_ 1784667329237352448
author He, Yina
Zhao, Tiantian
author_facet He, Yina
Zhao, Tiantian
author_sort He, Yina
collection PubMed
description When the human body is anesthetized, the human nerve tissue will be greatly affected, which also affects the breathing of the human body. The respiration during anesthesia is a lack of initiative, and the energy efficiency of the diaphragm in the lungs is very important to the safety of anesthesia. In this paper, the application of the ultrasound evaluation of the diaphragm in clinical anesthesia was studied. In this paper, 24 patients who underwent lung examination under medical anesthesia at our hospital were evaluated by the ultrasound vertical mixed echo method. Through patient voluntary selection and consent, 16 patients were examined with B-mode ultrasound and the other 8 patients with M-mode ultrasound to compare the effects of different ultrasounds on diaphragm image quality. In addition, this paper also analyzes the differences between different ultrasounds and the strengths and weaknesses of diaphragmatic ultrasound evaluation in clinical anesthesia. The suggestions of using different ultrasounds in ultrasonic evaluation are given. The study showed that 16 cases of B-mode ultrasound evaluation of the diaphragm obtained ultrasound images which showed a large field of vision, acoustic frequency between 7 and 18 MHz, and thickness difference between 0.35 and 0.52 cm. In 8 patients with the diaphragm evaluated by M-mode ultrasound, the local features of M-mode ultrasound images were clearer than those of B-mode ultrasound images, but the visual field area was smaller, the acoustic frequency was between 10 and 15 MHz, and the thickness difference was between 0.12 and 0.18 cm. Based on the above data, this paper suggests that, in the ultrasonic evaluation of the diaphragm, B-mode ultrasound should be used to check the patients first, and then M-mode ultrasound should be used to check the parts with poor quality so that the accurate diaphragm quality of patients can be obtained in the vast majority of patients.
format Online
Article
Text
id pubmed-8913060
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-89130602022-03-11 Ultrasound Evaluation of the Diaphragm in Clinical Anesthesia He, Yina Zhao, Tiantian J Healthc Eng Research Article When the human body is anesthetized, the human nerve tissue will be greatly affected, which also affects the breathing of the human body. The respiration during anesthesia is a lack of initiative, and the energy efficiency of the diaphragm in the lungs is very important to the safety of anesthesia. In this paper, the application of the ultrasound evaluation of the diaphragm in clinical anesthesia was studied. In this paper, 24 patients who underwent lung examination under medical anesthesia at our hospital were evaluated by the ultrasound vertical mixed echo method. Through patient voluntary selection and consent, 16 patients were examined with B-mode ultrasound and the other 8 patients with M-mode ultrasound to compare the effects of different ultrasounds on diaphragm image quality. In addition, this paper also analyzes the differences between different ultrasounds and the strengths and weaknesses of diaphragmatic ultrasound evaluation in clinical anesthesia. The suggestions of using different ultrasounds in ultrasonic evaluation are given. The study showed that 16 cases of B-mode ultrasound evaluation of the diaphragm obtained ultrasound images which showed a large field of vision, acoustic frequency between 7 and 18 MHz, and thickness difference between 0.35 and 0.52 cm. In 8 patients with the diaphragm evaluated by M-mode ultrasound, the local features of M-mode ultrasound images were clearer than those of B-mode ultrasound images, but the visual field area was smaller, the acoustic frequency was between 10 and 15 MHz, and the thickness difference was between 0.12 and 0.18 cm. Based on the above data, this paper suggests that, in the ultrasonic evaluation of the diaphragm, B-mode ultrasound should be used to check the patients first, and then M-mode ultrasound should be used to check the parts with poor quality so that the accurate diaphragm quality of patients can be obtained in the vast majority of patients. Hindawi 2022-03-03 /pmc/articles/PMC8913060/ /pubmed/35281531 http://dx.doi.org/10.1155/2022/2163225 Text en Copyright © 2022 Yina He and Tiantian Zhao. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
He, Yina
Zhao, Tiantian
Ultrasound Evaluation of the Diaphragm in Clinical Anesthesia
title Ultrasound Evaluation of the Diaphragm in Clinical Anesthesia
title_full Ultrasound Evaluation of the Diaphragm in Clinical Anesthesia
title_fullStr Ultrasound Evaluation of the Diaphragm in Clinical Anesthesia
title_full_unstemmed Ultrasound Evaluation of the Diaphragm in Clinical Anesthesia
title_short Ultrasound Evaluation of the Diaphragm in Clinical Anesthesia
title_sort ultrasound evaluation of the diaphragm in clinical anesthesia
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8913060/
https://www.ncbi.nlm.nih.gov/pubmed/35281531
http://dx.doi.org/10.1155/2022/2163225
work_keys_str_mv AT heyina ultrasoundevaluationofthediaphragminclinicalanesthesia
AT zhaotiantian ultrasoundevaluationofthediaphragminclinicalanesthesia