Cargando…

Visualising the Future of Orthopaedic Surgery: A Novel Application of Wireless Smart Glasses to Visualise Intraoperative Imaging

Smart glasses can provide a heads-up display of advanced imaging intraoperatively. In recent years, growing attention has been drawn to the use of smart glasses as an assistive technology to improve both efficiency and ergonomics in a surgical setting. Previous studies have reported improved surgica...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Se Ri, Park, Jae Yong, Ghani, Rafia, Ha, Joon, Hester, Thomas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8913437/
https://www.ncbi.nlm.nih.gov/pubmed/35340507
http://dx.doi.org/10.7759/cureus.22004
_version_ 1784667439701688320
author Park, Se Ri
Park, Jae Yong
Ghani, Rafia
Ha, Joon
Hester, Thomas
author_facet Park, Se Ri
Park, Jae Yong
Ghani, Rafia
Ha, Joon
Hester, Thomas
author_sort Park, Se Ri
collection PubMed
description Smart glasses can provide a heads-up display of advanced imaging intraoperatively. In recent years, growing attention has been drawn to the use of smart glasses as an assistive technology to improve both efficiency and ergonomics in a surgical setting. Previous studies have reported improved surgical accuracy, efficiency, and ergonomics with its usage, but its effectiveness as a form of intraoperative heads-up display remains elusive in the context of orthopaedics. This study provides a novel account of a wireless set-up of the Moverio BT-35E Smart Glasses (Suwa, Japan: Epson Inc.), incorporated in a complex orthopaedic procedure. Hind-foot nailing was performed on a patient with a complex open ankle fracture and multiple co-morbidities. Smart glasses were worn by the primary surgeon throughout the procedure to provide heads-up visualisation of the intraoperative fluoroscopy. In our surgical case, the surgeon experienced improved ergonomics and reduced disruption to focus with the use of smart glasses. The wireless set-up provided excellent signal transmission throughout the duration of the procedure. The wireless set-up of smart glasses is a potential solution for common occupational risks imposed on orthopaedic surgeons. Smart glasses minimise musculoskeletal strain from switching of vision from monitor to patient, whilst the wireless set-up allows for efficient use of space in an operating theatre and may potentially limit radiation exposure. Lastly, ergonomic benefits may increase the efficiency of movement for the surgeon, decreasing operative duration, and in turn minimising the risk of surgical complications for patients.
format Online
Article
Text
id pubmed-8913437
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-89134372022-03-25 Visualising the Future of Orthopaedic Surgery: A Novel Application of Wireless Smart Glasses to Visualise Intraoperative Imaging Park, Se Ri Park, Jae Yong Ghani, Rafia Ha, Joon Hester, Thomas Cureus Orthopedics Smart glasses can provide a heads-up display of advanced imaging intraoperatively. In recent years, growing attention has been drawn to the use of smart glasses as an assistive technology to improve both efficiency and ergonomics in a surgical setting. Previous studies have reported improved surgical accuracy, efficiency, and ergonomics with its usage, but its effectiveness as a form of intraoperative heads-up display remains elusive in the context of orthopaedics. This study provides a novel account of a wireless set-up of the Moverio BT-35E Smart Glasses (Suwa, Japan: Epson Inc.), incorporated in a complex orthopaedic procedure. Hind-foot nailing was performed on a patient with a complex open ankle fracture and multiple co-morbidities. Smart glasses were worn by the primary surgeon throughout the procedure to provide heads-up visualisation of the intraoperative fluoroscopy. In our surgical case, the surgeon experienced improved ergonomics and reduced disruption to focus with the use of smart glasses. The wireless set-up provided excellent signal transmission throughout the duration of the procedure. The wireless set-up of smart glasses is a potential solution for common occupational risks imposed on orthopaedic surgeons. Smart glasses minimise musculoskeletal strain from switching of vision from monitor to patient, whilst the wireless set-up allows for efficient use of space in an operating theatre and may potentially limit radiation exposure. Lastly, ergonomic benefits may increase the efficiency of movement for the surgeon, decreasing operative duration, and in turn minimising the risk of surgical complications for patients. Cureus 2022-02-08 /pmc/articles/PMC8913437/ /pubmed/35340507 http://dx.doi.org/10.7759/cureus.22004 Text en Copyright © 2022, Park et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Orthopedics
Park, Se Ri
Park, Jae Yong
Ghani, Rafia
Ha, Joon
Hester, Thomas
Visualising the Future of Orthopaedic Surgery: A Novel Application of Wireless Smart Glasses to Visualise Intraoperative Imaging
title Visualising the Future of Orthopaedic Surgery: A Novel Application of Wireless Smart Glasses to Visualise Intraoperative Imaging
title_full Visualising the Future of Orthopaedic Surgery: A Novel Application of Wireless Smart Glasses to Visualise Intraoperative Imaging
title_fullStr Visualising the Future of Orthopaedic Surgery: A Novel Application of Wireless Smart Glasses to Visualise Intraoperative Imaging
title_full_unstemmed Visualising the Future of Orthopaedic Surgery: A Novel Application of Wireless Smart Glasses to Visualise Intraoperative Imaging
title_short Visualising the Future of Orthopaedic Surgery: A Novel Application of Wireless Smart Glasses to Visualise Intraoperative Imaging
title_sort visualising the future of orthopaedic surgery: a novel application of wireless smart glasses to visualise intraoperative imaging
topic Orthopedics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8913437/
https://www.ncbi.nlm.nih.gov/pubmed/35340507
http://dx.doi.org/10.7759/cureus.22004
work_keys_str_mv AT parkseri visualisingthefutureoforthopaedicsurgeryanovelapplicationofwirelesssmartglassestovisualiseintraoperativeimaging
AT parkjaeyong visualisingthefutureoforthopaedicsurgeryanovelapplicationofwirelesssmartglassestovisualiseintraoperativeimaging
AT ghanirafia visualisingthefutureoforthopaedicsurgeryanovelapplicationofwirelesssmartglassestovisualiseintraoperativeimaging
AT hajoon visualisingthefutureoforthopaedicsurgeryanovelapplicationofwirelesssmartglassestovisualiseintraoperativeimaging
AT hesterthomas visualisingthefutureoforthopaedicsurgeryanovelapplicationofwirelesssmartglassestovisualiseintraoperativeimaging