Measurement of the retinal venous pressure with a new instrument in healthy subjects
BACKGROUND: The retinal venous pressure (RVP) is a determining factor for the blood supply of the retina as well as the optic nerve head and until recently has been measured by contact lens dynamometry (CLD). A new method has been developed, potentially offering better acceptance. The applicability...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8913447/ https://www.ncbi.nlm.nih.gov/pubmed/34499248 http://dx.doi.org/10.1007/s00417-021-05374-y |
_version_ | 1784667441702371328 |
---|---|
author | Stodtmeister, Richard Wetzk, Emilie Herber, Robert Pillunat, Karin R. Pillunat, Lutz E. |
author_facet | Stodtmeister, Richard Wetzk, Emilie Herber, Robert Pillunat, Karin R. Pillunat, Lutz E. |
author_sort | Stodtmeister, Richard |
collection | PubMed |
description | BACKGROUND: The retinal venous pressure (RVP) is a determining factor for the blood supply of the retina as well as the optic nerve head and until recently has been measured by contact lens dynamometry (CLD). A new method has been developed, potentially offering better acceptance. The applicability and the results of both methods were compared. METHODS: The type of this study is cross sectional. The subjects were 36 healthy volunteers, age 26 ± 5 years (mean ± s). Tonometry: rebound tonometer (RT) (iCare). The measurements were performed during an increase in airway pressure of 20 mmHg (Valsalva manoeuvre). Principle of RVP measurement: the central retinal vein (CRV) is observed during an increase of intraocular pressure (IOP) and at the start of pulsation, which corresponds with the RVP. Two different instruments for the IOP enhancement where used: contact lens dynamometry and the new instrument, IOPstim. Principle: a deflated balloon of 8 mm diameter—placed on the sclera laterally of the cornea—is filled with air. As soon as a venous pulsation occurs, filling is stopped and the IOP is measured, equalling the RVP. Examination procedure: randomization of the sequence: CLD or IOPstim, IOP, mydriasis, IOP three single measurements (SM) of the IOP with RT or of the pressure increase with CLD at an airway pressure of 20 mmHg, 5 min break, IOP, and three SM using the second method at equal pressure (20 mmHg). RESULTS: Spontaneous pulsation of the CRV was present in all 36 subjects. Pressures are given in mmHg. IOP in mydriasis 15.6 ± 3.3 (m ± s). Median RVP (MRVP)) of the three SM: CLD/IOPstim, 37.7 ± 5.2/24.7 ± 4.8 (t test: p < 0.001). Range of SM: 3.2 ± 1.8/2.9 ± 1.3 (t test: p = 0.36). Intraclass correlation coefficient (ICC) of SM: 0.88/0.83. ANOVA in SM: p = 0.48/0.08. MRVP CLD minus MRVP IOPstim: 13.0 ± 5.6. Ratio MRVP CLD/MRVP IOPstim: 1.56 ± 3.1. Cooperation and agreeability were slightly better with the IOPstim. CONCLUSION: This first study with the IOPstim in humans was deliberately performed in healthy volunteers using Valsalva conditions. As demonstrated by ICC and ANOVA, reproducible SM can be obtained by both methods and the range of the SM does not differ greatly. The higher MRVP in CLD could be explained by the different directions of the force vectors. [Image: see text] |
format | Online Article Text |
id | pubmed-8913447 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-89134472022-03-15 Measurement of the retinal venous pressure with a new instrument in healthy subjects Stodtmeister, Richard Wetzk, Emilie Herber, Robert Pillunat, Karin R. Pillunat, Lutz E. Graefes Arch Clin Exp Ophthalmol Glaucoma BACKGROUND: The retinal venous pressure (RVP) is a determining factor for the blood supply of the retina as well as the optic nerve head and until recently has been measured by contact lens dynamometry (CLD). A new method has been developed, potentially offering better acceptance. The applicability and the results of both methods were compared. METHODS: The type of this study is cross sectional. The subjects were 36 healthy volunteers, age 26 ± 5 years (mean ± s). Tonometry: rebound tonometer (RT) (iCare). The measurements were performed during an increase in airway pressure of 20 mmHg (Valsalva manoeuvre). Principle of RVP measurement: the central retinal vein (CRV) is observed during an increase of intraocular pressure (IOP) and at the start of pulsation, which corresponds with the RVP. Two different instruments for the IOP enhancement where used: contact lens dynamometry and the new instrument, IOPstim. Principle: a deflated balloon of 8 mm diameter—placed on the sclera laterally of the cornea—is filled with air. As soon as a venous pulsation occurs, filling is stopped and the IOP is measured, equalling the RVP. Examination procedure: randomization of the sequence: CLD or IOPstim, IOP, mydriasis, IOP three single measurements (SM) of the IOP with RT or of the pressure increase with CLD at an airway pressure of 20 mmHg, 5 min break, IOP, and three SM using the second method at equal pressure (20 mmHg). RESULTS: Spontaneous pulsation of the CRV was present in all 36 subjects. Pressures are given in mmHg. IOP in mydriasis 15.6 ± 3.3 (m ± s). Median RVP (MRVP)) of the three SM: CLD/IOPstim, 37.7 ± 5.2/24.7 ± 4.8 (t test: p < 0.001). Range of SM: 3.2 ± 1.8/2.9 ± 1.3 (t test: p = 0.36). Intraclass correlation coefficient (ICC) of SM: 0.88/0.83. ANOVA in SM: p = 0.48/0.08. MRVP CLD minus MRVP IOPstim: 13.0 ± 5.6. Ratio MRVP CLD/MRVP IOPstim: 1.56 ± 3.1. Cooperation and agreeability were slightly better with the IOPstim. CONCLUSION: This first study with the IOPstim in humans was deliberately performed in healthy volunteers using Valsalva conditions. As demonstrated by ICC and ANOVA, reproducible SM can be obtained by both methods and the range of the SM does not differ greatly. The higher MRVP in CLD could be explained by the different directions of the force vectors. [Image: see text] Springer Berlin Heidelberg 2021-09-09 2022 /pmc/articles/PMC8913447/ /pubmed/34499248 http://dx.doi.org/10.1007/s00417-021-05374-y Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Glaucoma Stodtmeister, Richard Wetzk, Emilie Herber, Robert Pillunat, Karin R. Pillunat, Lutz E. Measurement of the retinal venous pressure with a new instrument in healthy subjects |
title | Measurement of the retinal venous pressure with a new instrument in healthy subjects |
title_full | Measurement of the retinal venous pressure with a new instrument in healthy subjects |
title_fullStr | Measurement of the retinal venous pressure with a new instrument in healthy subjects |
title_full_unstemmed | Measurement of the retinal venous pressure with a new instrument in healthy subjects |
title_short | Measurement of the retinal venous pressure with a new instrument in healthy subjects |
title_sort | measurement of the retinal venous pressure with a new instrument in healthy subjects |
topic | Glaucoma |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8913447/ https://www.ncbi.nlm.nih.gov/pubmed/34499248 http://dx.doi.org/10.1007/s00417-021-05374-y |
work_keys_str_mv | AT stodtmeisterrichard measurementoftheretinalvenouspressurewithanewinstrumentinhealthysubjects AT wetzkemilie measurementoftheretinalvenouspressurewithanewinstrumentinhealthysubjects AT herberrobert measurementoftheretinalvenouspressurewithanewinstrumentinhealthysubjects AT pillunatkarinr measurementoftheretinalvenouspressurewithanewinstrumentinhealthysubjects AT pillunatlutze measurementoftheretinalvenouspressurewithanewinstrumentinhealthysubjects |