Cargando…

Removal of MIRAgel scleral buckle implants using Yankauer suction catheter with adjusted diameter

PURPOSE: A variety of removal methods have been reported for cases wherein MIRAgel-associated complications have occurred. Recently, Santorum et al. reported an aspiration method using a metal microcannula. Herein, we report a novel alternative approach using Yankauer suction catheter based on Santo...

Descripción completa

Detalles Bibliográficos
Autores principales: Nakao, Shintaro, Nishida, Takashi, Sonoda, Koh-Hei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8914329/
https://www.ncbi.nlm.nih.gov/pubmed/35282604
http://dx.doi.org/10.1016/j.ajoc.2022.101470
_version_ 1784667679009800192
author Nakao, Shintaro
Nishida, Takashi
Sonoda, Koh-Hei
author_facet Nakao, Shintaro
Nishida, Takashi
Sonoda, Koh-Hei
author_sort Nakao, Shintaro
collection PubMed
description PURPOSE: A variety of removal methods have been reported for cases wherein MIRAgel-associated complications have occurred. Recently, Santorum et al. reported an aspiration method using a metal microcannula. Herein, we report a novel alternative approach using Yankauer suction catheter based on Santorum et al.‘s method. OBSERVATIONS: This retrospective case involved a 40-year-old Caucasian man with MIRAgel implant-associated swelling-related complications (strabismus and disfiguring mass effect), who underwent suction-assisted implant removal in January 2020 at Kyushu University Hospital. Surgery was conducted under general anesthesia with an incision made in the superior quadrant, and the degraded MIRAgel implant was aspirated using a Yankauer suction catheter instrument with its diameter adjusted to the space. At the one-month follow-up, there were no early postsurgical complications, and the retina remained completely attached. CONCLUSIONS: Yankauer suction catheter is a useful instrument for removal of MIRAgel scleral buckle implants. It is made up of polyvinyl chloride, which is safer and cheaper, and can be cut to adjust the instrument's diameter according to the surgical field.
format Online
Article
Text
id pubmed-8914329
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-89143292022-03-12 Removal of MIRAgel scleral buckle implants using Yankauer suction catheter with adjusted diameter Nakao, Shintaro Nishida, Takashi Sonoda, Koh-Hei Am J Ophthalmol Case Rep Case Report PURPOSE: A variety of removal methods have been reported for cases wherein MIRAgel-associated complications have occurred. Recently, Santorum et al. reported an aspiration method using a metal microcannula. Herein, we report a novel alternative approach using Yankauer suction catheter based on Santorum et al.‘s method. OBSERVATIONS: This retrospective case involved a 40-year-old Caucasian man with MIRAgel implant-associated swelling-related complications (strabismus and disfiguring mass effect), who underwent suction-assisted implant removal in January 2020 at Kyushu University Hospital. Surgery was conducted under general anesthesia with an incision made in the superior quadrant, and the degraded MIRAgel implant was aspirated using a Yankauer suction catheter instrument with its diameter adjusted to the space. At the one-month follow-up, there were no early postsurgical complications, and the retina remained completely attached. CONCLUSIONS: Yankauer suction catheter is a useful instrument for removal of MIRAgel scleral buckle implants. It is made up of polyvinyl chloride, which is safer and cheaper, and can be cut to adjust the instrument's diameter according to the surgical field. Elsevier 2022-03-07 /pmc/articles/PMC8914329/ /pubmed/35282604 http://dx.doi.org/10.1016/j.ajoc.2022.101470 Text en © 2022 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Nakao, Shintaro
Nishida, Takashi
Sonoda, Koh-Hei
Removal of MIRAgel scleral buckle implants using Yankauer suction catheter with adjusted diameter
title Removal of MIRAgel scleral buckle implants using Yankauer suction catheter with adjusted diameter
title_full Removal of MIRAgel scleral buckle implants using Yankauer suction catheter with adjusted diameter
title_fullStr Removal of MIRAgel scleral buckle implants using Yankauer suction catheter with adjusted diameter
title_full_unstemmed Removal of MIRAgel scleral buckle implants using Yankauer suction catheter with adjusted diameter
title_short Removal of MIRAgel scleral buckle implants using Yankauer suction catheter with adjusted diameter
title_sort removal of miragel scleral buckle implants using yankauer suction catheter with adjusted diameter
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8914329/
https://www.ncbi.nlm.nih.gov/pubmed/35282604
http://dx.doi.org/10.1016/j.ajoc.2022.101470
work_keys_str_mv AT nakaoshintaro removalofmiragelscleralbuckleimplantsusingyankauersuctioncatheterwithadjusteddiameter
AT nishidatakashi removalofmiragelscleralbuckleimplantsusingyankauersuctioncatheterwithadjusteddiameter
AT sonodakohhei removalofmiragelscleralbuckleimplantsusingyankauersuctioncatheterwithadjusteddiameter