Cargando…
The Movesense Medical Sensor Chest Belt Device as Single Channel ECG for RR Interval Detection and HRV Analysis during Resting State and Incremental Exercise: A Cross-Sectional Validation Study
The value of heart rate variability (HRV) in the fields of health, disease, and exercise science has been established through numerous investigations. The typical mobile-based HRV device simply records interbeat intervals, without differentiation between noise or arrythmia as can be done with an ele...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8914935/ https://www.ncbi.nlm.nih.gov/pubmed/35271179 http://dx.doi.org/10.3390/s22052032 |
_version_ | 1784667879195541504 |
---|---|
author | Rogers, Bruce Schaffarczyk, Marcelle Clauß, Martina Mourot, Laurent Gronwald, Thomas |
author_facet | Rogers, Bruce Schaffarczyk, Marcelle Clauß, Martina Mourot, Laurent Gronwald, Thomas |
author_sort | Rogers, Bruce |
collection | PubMed |
description | The value of heart rate variability (HRV) in the fields of health, disease, and exercise science has been established through numerous investigations. The typical mobile-based HRV device simply records interbeat intervals, without differentiation between noise or arrythmia as can be done with an electrocardiogram (ECG). The intent of this report is to validate a new single channel ECG device, the Movesense Medical sensor, against a conventional 12 channel ECG. A heterogeneous group of 21 participants performed an incremental cycling ramp to failure with measurements of HRV, before (PRE), during (EX), and after (POST). Results showed excellent correlations between devices for linear indexes with Pearson’s r between 0.98 to 1.0 for meanRR, SDNN, RMSSD, and 0.95 to 0.97 for the non-linear index DFA a1 during PRE, EX, and POST. There was no significant difference in device specific meanRR during PRE and POST. Bland–Altman analysis showed high agreement between devices (PRE and POST: meanRR bias of 0.0 and 0.4 ms, LOA of 1.9 to −1.8 ms and 2.3 to −1.5; EX: meanRR bias of 11.2 to 6.0 ms; LOA of 29.8 to −7.4 ms during low intensity exercise and 8.5 to 3.5 ms during high intensity exercise). The Movesense Medical device can be used in lieu of a reference ECG for the calculation of HRV with the potential to differentiate noise from atrial fibrillation and represents a significant advance in both a HR and HRV recording device in a chest belt form factor for lab-based or remote field-application. |
format | Online Article Text |
id | pubmed-8914935 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-89149352022-03-12 The Movesense Medical Sensor Chest Belt Device as Single Channel ECG for RR Interval Detection and HRV Analysis during Resting State and Incremental Exercise: A Cross-Sectional Validation Study Rogers, Bruce Schaffarczyk, Marcelle Clauß, Martina Mourot, Laurent Gronwald, Thomas Sensors (Basel) Article The value of heart rate variability (HRV) in the fields of health, disease, and exercise science has been established through numerous investigations. The typical mobile-based HRV device simply records interbeat intervals, without differentiation between noise or arrythmia as can be done with an electrocardiogram (ECG). The intent of this report is to validate a new single channel ECG device, the Movesense Medical sensor, against a conventional 12 channel ECG. A heterogeneous group of 21 participants performed an incremental cycling ramp to failure with measurements of HRV, before (PRE), during (EX), and after (POST). Results showed excellent correlations between devices for linear indexes with Pearson’s r between 0.98 to 1.0 for meanRR, SDNN, RMSSD, and 0.95 to 0.97 for the non-linear index DFA a1 during PRE, EX, and POST. There was no significant difference in device specific meanRR during PRE and POST. Bland–Altman analysis showed high agreement between devices (PRE and POST: meanRR bias of 0.0 and 0.4 ms, LOA of 1.9 to −1.8 ms and 2.3 to −1.5; EX: meanRR bias of 11.2 to 6.0 ms; LOA of 29.8 to −7.4 ms during low intensity exercise and 8.5 to 3.5 ms during high intensity exercise). The Movesense Medical device can be used in lieu of a reference ECG for the calculation of HRV with the potential to differentiate noise from atrial fibrillation and represents a significant advance in both a HR and HRV recording device in a chest belt form factor for lab-based or remote field-application. MDPI 2022-03-05 /pmc/articles/PMC8914935/ /pubmed/35271179 http://dx.doi.org/10.3390/s22052032 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Rogers, Bruce Schaffarczyk, Marcelle Clauß, Martina Mourot, Laurent Gronwald, Thomas The Movesense Medical Sensor Chest Belt Device as Single Channel ECG for RR Interval Detection and HRV Analysis during Resting State and Incremental Exercise: A Cross-Sectional Validation Study |
title | The Movesense Medical Sensor Chest Belt Device as Single Channel ECG for RR Interval Detection and HRV Analysis during Resting State and Incremental Exercise: A Cross-Sectional Validation Study |
title_full | The Movesense Medical Sensor Chest Belt Device as Single Channel ECG for RR Interval Detection and HRV Analysis during Resting State and Incremental Exercise: A Cross-Sectional Validation Study |
title_fullStr | The Movesense Medical Sensor Chest Belt Device as Single Channel ECG for RR Interval Detection and HRV Analysis during Resting State and Incremental Exercise: A Cross-Sectional Validation Study |
title_full_unstemmed | The Movesense Medical Sensor Chest Belt Device as Single Channel ECG for RR Interval Detection and HRV Analysis during Resting State and Incremental Exercise: A Cross-Sectional Validation Study |
title_short | The Movesense Medical Sensor Chest Belt Device as Single Channel ECG for RR Interval Detection and HRV Analysis during Resting State and Incremental Exercise: A Cross-Sectional Validation Study |
title_sort | movesense medical sensor chest belt device as single channel ecg for rr interval detection and hrv analysis during resting state and incremental exercise: a cross-sectional validation study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8914935/ https://www.ncbi.nlm.nih.gov/pubmed/35271179 http://dx.doi.org/10.3390/s22052032 |
work_keys_str_mv | AT rogersbruce themovesensemedicalsensorchestbeltdeviceassinglechannelecgforrrintervaldetectionandhrvanalysisduringrestingstateandincrementalexerciseacrosssectionalvalidationstudy AT schaffarczykmarcelle themovesensemedicalsensorchestbeltdeviceassinglechannelecgforrrintervaldetectionandhrvanalysisduringrestingstateandincrementalexerciseacrosssectionalvalidationstudy AT claußmartina themovesensemedicalsensorchestbeltdeviceassinglechannelecgforrrintervaldetectionandhrvanalysisduringrestingstateandincrementalexerciseacrosssectionalvalidationstudy AT mourotlaurent themovesensemedicalsensorchestbeltdeviceassinglechannelecgforrrintervaldetectionandhrvanalysisduringrestingstateandincrementalexerciseacrosssectionalvalidationstudy AT gronwaldthomas themovesensemedicalsensorchestbeltdeviceassinglechannelecgforrrintervaldetectionandhrvanalysisduringrestingstateandincrementalexerciseacrosssectionalvalidationstudy AT rogersbruce movesensemedicalsensorchestbeltdeviceassinglechannelecgforrrintervaldetectionandhrvanalysisduringrestingstateandincrementalexerciseacrosssectionalvalidationstudy AT schaffarczykmarcelle movesensemedicalsensorchestbeltdeviceassinglechannelecgforrrintervaldetectionandhrvanalysisduringrestingstateandincrementalexerciseacrosssectionalvalidationstudy AT claußmartina movesensemedicalsensorchestbeltdeviceassinglechannelecgforrrintervaldetectionandhrvanalysisduringrestingstateandincrementalexerciseacrosssectionalvalidationstudy AT mourotlaurent movesensemedicalsensorchestbeltdeviceassinglechannelecgforrrintervaldetectionandhrvanalysisduringrestingstateandincrementalexerciseacrosssectionalvalidationstudy AT gronwaldthomas movesensemedicalsensorchestbeltdeviceassinglechannelecgforrrintervaldetectionandhrvanalysisduringrestingstateandincrementalexerciseacrosssectionalvalidationstudy |