Cargando…

Signal Quality Investigation of a New Wearable Frontal Lobe EEG Device

The demand for non-laboratory and long-term EEG acquisition in scientific and clinical applications has put forward new requirements for wearable EEG devices. In this paper, a new wearable frontal EEG device called Mindeep was proposed. A signal quality study was then conducted, which included simul...

Descripción completa

Detalles Bibliográficos
Autores principales: Gao, Zhilin, Cui, Xingran, Wan, Wang, Qin, Zeguang, Gu, Zhongze
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8914983/
https://www.ncbi.nlm.nih.gov/pubmed/35271044
http://dx.doi.org/10.3390/s22051898
_version_ 1784667893801156608
author Gao, Zhilin
Cui, Xingran
Wan, Wang
Qin, Zeguang
Gu, Zhongze
author_facet Gao, Zhilin
Cui, Xingran
Wan, Wang
Qin, Zeguang
Gu, Zhongze
author_sort Gao, Zhilin
collection PubMed
description The demand for non-laboratory and long-term EEG acquisition in scientific and clinical applications has put forward new requirements for wearable EEG devices. In this paper, a new wearable frontal EEG device called Mindeep was proposed. A signal quality study was then conducted, which included simulated signal tests and signal quality comparison experiments. Simulated signals with different frequencies and amplitudes were used to test the stability of Mindeep’s circuit, and the high correlation coefficients (>0.9) proved that Mindeep has a stable and reliable hardware circuit. The signal quality comparison experiment, between Mindeep and the gold standard device, Neuroscan, included three tasks: (1) resting; (2) auditory oddball; and (3) attention. In the resting state, the average normalized cross-correlation coefficients between EEG signals recorded by the two devices was around 0.72 ± 0.02, Berger effect was observed (p < 0.01), and the comparison results in the time and frequency domain illustrated the ability of Mindeep to record high-quality EEG signals. The significant differences between high tone and low tone in auditory event-related potential collected by Mindeep was observed in N2 and P2. The attention recognition accuracy of Mindeep achieved 71.12% and 74.76% based on EEG features and the XGBoost model in the two attention tasks, respectively, which were higher than that of Neuroscan (70.19% and 72.80%). The results validated the performance of Mindeep as a prefrontal EEG recording device, which has a wide range of potential applications in audiology, cognitive neuroscience, and daily requirements.
format Online
Article
Text
id pubmed-8914983
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-89149832022-03-12 Signal Quality Investigation of a New Wearable Frontal Lobe EEG Device Gao, Zhilin Cui, Xingran Wan, Wang Qin, Zeguang Gu, Zhongze Sensors (Basel) Article The demand for non-laboratory and long-term EEG acquisition in scientific and clinical applications has put forward new requirements for wearable EEG devices. In this paper, a new wearable frontal EEG device called Mindeep was proposed. A signal quality study was then conducted, which included simulated signal tests and signal quality comparison experiments. Simulated signals with different frequencies and amplitudes were used to test the stability of Mindeep’s circuit, and the high correlation coefficients (>0.9) proved that Mindeep has a stable and reliable hardware circuit. The signal quality comparison experiment, between Mindeep and the gold standard device, Neuroscan, included three tasks: (1) resting; (2) auditory oddball; and (3) attention. In the resting state, the average normalized cross-correlation coefficients between EEG signals recorded by the two devices was around 0.72 ± 0.02, Berger effect was observed (p < 0.01), and the comparison results in the time and frequency domain illustrated the ability of Mindeep to record high-quality EEG signals. The significant differences between high tone and low tone in auditory event-related potential collected by Mindeep was observed in N2 and P2. The attention recognition accuracy of Mindeep achieved 71.12% and 74.76% based on EEG features and the XGBoost model in the two attention tasks, respectively, which were higher than that of Neuroscan (70.19% and 72.80%). The results validated the performance of Mindeep as a prefrontal EEG recording device, which has a wide range of potential applications in audiology, cognitive neuroscience, and daily requirements. MDPI 2022-02-28 /pmc/articles/PMC8914983/ /pubmed/35271044 http://dx.doi.org/10.3390/s22051898 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Gao, Zhilin
Cui, Xingran
Wan, Wang
Qin, Zeguang
Gu, Zhongze
Signal Quality Investigation of a New Wearable Frontal Lobe EEG Device
title Signal Quality Investigation of a New Wearable Frontal Lobe EEG Device
title_full Signal Quality Investigation of a New Wearable Frontal Lobe EEG Device
title_fullStr Signal Quality Investigation of a New Wearable Frontal Lobe EEG Device
title_full_unstemmed Signal Quality Investigation of a New Wearable Frontal Lobe EEG Device
title_short Signal Quality Investigation of a New Wearable Frontal Lobe EEG Device
title_sort signal quality investigation of a new wearable frontal lobe eeg device
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8914983/
https://www.ncbi.nlm.nih.gov/pubmed/35271044
http://dx.doi.org/10.3390/s22051898
work_keys_str_mv AT gaozhilin signalqualityinvestigationofanewwearablefrontallobeeegdevice
AT cuixingran signalqualityinvestigationofanewwearablefrontallobeeegdevice
AT wanwang signalqualityinvestigationofanewwearablefrontallobeeegdevice
AT qinzeguang signalqualityinvestigationofanewwearablefrontallobeeegdevice
AT guzhongze signalqualityinvestigationofanewwearablefrontallobeeegdevice