Cargando…

Case Report: Initial Evidence of Safety and Efficacy of High Definition-Transcranial Direct Current Stimulation in a Patient With Neuropathic Pain and Implanted Spinal Cord Stimulator

Neuropathic pain (NP), often treatment-refractory, is one of the most debilitating conditions contributing to suffering and disability worldwide. Recently, non-invasive neuromodulation techniques, particularly repetitive transcranial magnetic stimulation (rTMS) and transcranial direct current stimul...

Descripción completa

Detalles Bibliográficos
Autores principales: Deblieck, Choi, Smeijers, Steven, Morlion, Bart, Datta, Abhishek, Thomas, Chris, Theys, Tom
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8915614/
https://www.ncbi.nlm.nih.gov/pubmed/35295503
http://dx.doi.org/10.3389/fpain.2021.753464
_version_ 1784668072528838656
author Deblieck, Choi
Smeijers, Steven
Morlion, Bart
Datta, Abhishek
Thomas, Chris
Theys, Tom
author_facet Deblieck, Choi
Smeijers, Steven
Morlion, Bart
Datta, Abhishek
Thomas, Chris
Theys, Tom
author_sort Deblieck, Choi
collection PubMed
description Neuropathic pain (NP), often treatment-refractory, is one of the most debilitating conditions contributing to suffering and disability worldwide. Recently, non-invasive neuromodulation techniques, particularly repetitive transcranial magnetic stimulation (rTMS) and transcranial direct current stimulation (tDCS) have emerged as potential therapeutic alternatives due to their ability to alter cortical excitability of neural circuits. However, the magnetic field induced in rTMS may be unsafe for patients with an implanted electrode in the head or neck area while tDCS poses no theoretical risk of injury to these patients. High definition (HD)-tDCS is a novel, more focal technique of tDCS and may be safer to the patient compared to the more diffuse stimulation of conventional tDCS. To our knowledge, no study has ever demonstrated the safety and/or feasibility of HD-tDCS in patients with spinal cord stimulation (SCS) devices using computational modeling of induced electrical fields. Furthermore, this study highlights the potential use of (HD-)tDCS as predictive tool for a positive response in chronic epidural motor cortex stimulation (MCS), especially in patients with an implanted device not suitable for rTMS. In a 54-year-old woman with an implanted spinal cord stimulation (SCS) system for another pain syndrome, HD-tDCS was initiated for refractory post-surgical inferior alveolar nerve neuropathy. She was submitted to 7 days of anodal HD-tDCS over the left motor cortex at 1.5 mA for 30 min. A notable decrease in pain perception was observed, lasting for approximately 5–6 h (Numeric Rating Score decreased from 8 to 4.34). No adverse events were reported. The stimulation parameters and clinical efficacy of the SCS system remained unchanged. Additionally, computational analysis indicated no meaningful alteration of current flow when considering a model with a SCS implant with respect to a model without implant. Regarding the positive therapeutic effect of HD-tDCS, the patient was selected for an epidural MCS trial and subsequent implantation, which showed short-term pain relief of 50–75%. Although one case does not demonstrate efficacy, tolerability, or safety to the novel intervention, it paves the way for better diagnosis and treatment for patients who are otherwise excluded from other non-invasive neuromodulation techniques, such as rTMS. A positive tDCS effect could be a potential biomarker for positive epidural MCS response in patients with an implanted stimulation device non-compatible with rTMS.
format Online
Article
Text
id pubmed-8915614
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-89156142022-03-15 Case Report: Initial Evidence of Safety and Efficacy of High Definition-Transcranial Direct Current Stimulation in a Patient With Neuropathic Pain and Implanted Spinal Cord Stimulator Deblieck, Choi Smeijers, Steven Morlion, Bart Datta, Abhishek Thomas, Chris Theys, Tom Front Pain Res (Lausanne) Pain Research Neuropathic pain (NP), often treatment-refractory, is one of the most debilitating conditions contributing to suffering and disability worldwide. Recently, non-invasive neuromodulation techniques, particularly repetitive transcranial magnetic stimulation (rTMS) and transcranial direct current stimulation (tDCS) have emerged as potential therapeutic alternatives due to their ability to alter cortical excitability of neural circuits. However, the magnetic field induced in rTMS may be unsafe for patients with an implanted electrode in the head or neck area while tDCS poses no theoretical risk of injury to these patients. High definition (HD)-tDCS is a novel, more focal technique of tDCS and may be safer to the patient compared to the more diffuse stimulation of conventional tDCS. To our knowledge, no study has ever demonstrated the safety and/or feasibility of HD-tDCS in patients with spinal cord stimulation (SCS) devices using computational modeling of induced electrical fields. Furthermore, this study highlights the potential use of (HD-)tDCS as predictive tool for a positive response in chronic epidural motor cortex stimulation (MCS), especially in patients with an implanted device not suitable for rTMS. In a 54-year-old woman with an implanted spinal cord stimulation (SCS) system for another pain syndrome, HD-tDCS was initiated for refractory post-surgical inferior alveolar nerve neuropathy. She was submitted to 7 days of anodal HD-tDCS over the left motor cortex at 1.5 mA for 30 min. A notable decrease in pain perception was observed, lasting for approximately 5–6 h (Numeric Rating Score decreased from 8 to 4.34). No adverse events were reported. The stimulation parameters and clinical efficacy of the SCS system remained unchanged. Additionally, computational analysis indicated no meaningful alteration of current flow when considering a model with a SCS implant with respect to a model without implant. Regarding the positive therapeutic effect of HD-tDCS, the patient was selected for an epidural MCS trial and subsequent implantation, which showed short-term pain relief of 50–75%. Although one case does not demonstrate efficacy, tolerability, or safety to the novel intervention, it paves the way for better diagnosis and treatment for patients who are otherwise excluded from other non-invasive neuromodulation techniques, such as rTMS. A positive tDCS effect could be a potential biomarker for positive epidural MCS response in patients with an implanted stimulation device non-compatible with rTMS. Frontiers Media S.A. 2021-11-18 /pmc/articles/PMC8915614/ /pubmed/35295503 http://dx.doi.org/10.3389/fpain.2021.753464 Text en Copyright © 2021 Deblieck, Smeijers, Morlion, Datta, Thomas and Theys. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Pain Research
Deblieck, Choi
Smeijers, Steven
Morlion, Bart
Datta, Abhishek
Thomas, Chris
Theys, Tom
Case Report: Initial Evidence of Safety and Efficacy of High Definition-Transcranial Direct Current Stimulation in a Patient With Neuropathic Pain and Implanted Spinal Cord Stimulator
title Case Report: Initial Evidence of Safety and Efficacy of High Definition-Transcranial Direct Current Stimulation in a Patient With Neuropathic Pain and Implanted Spinal Cord Stimulator
title_full Case Report: Initial Evidence of Safety and Efficacy of High Definition-Transcranial Direct Current Stimulation in a Patient With Neuropathic Pain and Implanted Spinal Cord Stimulator
title_fullStr Case Report: Initial Evidence of Safety and Efficacy of High Definition-Transcranial Direct Current Stimulation in a Patient With Neuropathic Pain and Implanted Spinal Cord Stimulator
title_full_unstemmed Case Report: Initial Evidence of Safety and Efficacy of High Definition-Transcranial Direct Current Stimulation in a Patient With Neuropathic Pain and Implanted Spinal Cord Stimulator
title_short Case Report: Initial Evidence of Safety and Efficacy of High Definition-Transcranial Direct Current Stimulation in a Patient With Neuropathic Pain and Implanted Spinal Cord Stimulator
title_sort case report: initial evidence of safety and efficacy of high definition-transcranial direct current stimulation in a patient with neuropathic pain and implanted spinal cord stimulator
topic Pain Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8915614/
https://www.ncbi.nlm.nih.gov/pubmed/35295503
http://dx.doi.org/10.3389/fpain.2021.753464
work_keys_str_mv AT deblieckchoi casereportinitialevidenceofsafetyandefficacyofhighdefinitiontranscranialdirectcurrentstimulationinapatientwithneuropathicpainandimplantedspinalcordstimulator
AT smeijerssteven casereportinitialevidenceofsafetyandefficacyofhighdefinitiontranscranialdirectcurrentstimulationinapatientwithneuropathicpainandimplantedspinalcordstimulator
AT morlionbart casereportinitialevidenceofsafetyandefficacyofhighdefinitiontranscranialdirectcurrentstimulationinapatientwithneuropathicpainandimplantedspinalcordstimulator
AT dattaabhishek casereportinitialevidenceofsafetyandefficacyofhighdefinitiontranscranialdirectcurrentstimulationinapatientwithneuropathicpainandimplantedspinalcordstimulator
AT thomaschris casereportinitialevidenceofsafetyandefficacyofhighdefinitiontranscranialdirectcurrentstimulationinapatientwithneuropathicpainandimplantedspinalcordstimulator
AT theystom casereportinitialevidenceofsafetyandefficacyofhighdefinitiontranscranialdirectcurrentstimulationinapatientwithneuropathicpainandimplantedspinalcordstimulator