Cargando…

Inverted internal limiting membrane flap technique for retinal detachment due to macular holes in high myopia with axial length ≥ 30 mm

To compare the efficacy of internal limiting membrane (ILM) flap covering to that of ILM flap insertion for the treatment of macular hole retinal detachment (MHRD) in highly myopic eyes with axial length (AL) ≥ 30 mm. We retrospectively analysed the medical records of 48 MHRD patients with high myop...

Descripción completa

Detalles Bibliográficos
Autores principales: Xu, Changzhong, Feng, Chao, Han, Mengyao, He, Junwen, Zhang, Rui, Yan, Tao, Li, Xiangyun, Liu, Yong, Li, Yanzi, Wu, Jianhua
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8917174/
https://www.ncbi.nlm.nih.gov/pubmed/35277581
http://dx.doi.org/10.1038/s41598-022-08277-y
_version_ 1784668485697142784
author Xu, Changzhong
Feng, Chao
Han, Mengyao
He, Junwen
Zhang, Rui
Yan, Tao
Li, Xiangyun
Liu, Yong
Li, Yanzi
Wu, Jianhua
author_facet Xu, Changzhong
Feng, Chao
Han, Mengyao
He, Junwen
Zhang, Rui
Yan, Tao
Li, Xiangyun
Liu, Yong
Li, Yanzi
Wu, Jianhua
author_sort Xu, Changzhong
collection PubMed
description To compare the efficacy of internal limiting membrane (ILM) flap covering to that of ILM flap insertion for the treatment of macular hole retinal detachment (MHRD) in highly myopic eyes with axial length (AL) ≥ 30 mm. We retrospectively analysed the medical records of 48 MHRD patients with high myopia (AL ≥ 30 mm). According to different surgical methods, the patients were divided into a covering group (23 eyes) and an insertion group (25 eyes). The rate of retinal reattachment and MH closure were compared between the two groups, and the related factors affecting the initial anatomical results were analysed. After primary vitrectomy and single silicone oil removal, there were 18 eyes (78.3%) in the covering group, and 20 eyes (80.0%) in the insertion group had retinal reattachment (P = 1.000). Moreover, 16 eyes (69.6%) in the covering group and 17 eyes (68.0%) in the insertion group had their MHs sealed (P = 0.907). The best-corrected visual acuity (BCVA) at 12 months and the improvement in BCVA postoperatively in the two groups were not statistically significant (P = 0.543, 0.955). Logistic regression analysis showed that elongated AL (OR = 1.844, 95% CI 1.037–3.280, P = 0.037) and higher choroidal atrophy (OR = 2.986, 95% CI 1.011–8.821, P = 0.048) were risk factors affecting initial anatomical success. For extremely high-myopia MHRD with AL ≥ 30 mm, ILM flap covering and insertion can both effectively seal the MH and promote retinal reattachment, but the visual function improvement may still be limited. The longer the AL and the higher the choroidal atrophy, the greater is the risk of initial anatomical failure.
format Online
Article
Text
id pubmed-8917174
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-89171742022-03-14 Inverted internal limiting membrane flap technique for retinal detachment due to macular holes in high myopia with axial length ≥ 30 mm Xu, Changzhong Feng, Chao Han, Mengyao He, Junwen Zhang, Rui Yan, Tao Li, Xiangyun Liu, Yong Li, Yanzi Wu, Jianhua Sci Rep Article To compare the efficacy of internal limiting membrane (ILM) flap covering to that of ILM flap insertion for the treatment of macular hole retinal detachment (MHRD) in highly myopic eyes with axial length (AL) ≥ 30 mm. We retrospectively analysed the medical records of 48 MHRD patients with high myopia (AL ≥ 30 mm). According to different surgical methods, the patients were divided into a covering group (23 eyes) and an insertion group (25 eyes). The rate of retinal reattachment and MH closure were compared between the two groups, and the related factors affecting the initial anatomical results were analysed. After primary vitrectomy and single silicone oil removal, there were 18 eyes (78.3%) in the covering group, and 20 eyes (80.0%) in the insertion group had retinal reattachment (P = 1.000). Moreover, 16 eyes (69.6%) in the covering group and 17 eyes (68.0%) in the insertion group had their MHs sealed (P = 0.907). The best-corrected visual acuity (BCVA) at 12 months and the improvement in BCVA postoperatively in the two groups were not statistically significant (P = 0.543, 0.955). Logistic regression analysis showed that elongated AL (OR = 1.844, 95% CI 1.037–3.280, P = 0.037) and higher choroidal atrophy (OR = 2.986, 95% CI 1.011–8.821, P = 0.048) were risk factors affecting initial anatomical success. For extremely high-myopia MHRD with AL ≥ 30 mm, ILM flap covering and insertion can both effectively seal the MH and promote retinal reattachment, but the visual function improvement may still be limited. The longer the AL and the higher the choroidal atrophy, the greater is the risk of initial anatomical failure. Nature Publishing Group UK 2022-03-11 /pmc/articles/PMC8917174/ /pubmed/35277581 http://dx.doi.org/10.1038/s41598-022-08277-y Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Xu, Changzhong
Feng, Chao
Han, Mengyao
He, Junwen
Zhang, Rui
Yan, Tao
Li, Xiangyun
Liu, Yong
Li, Yanzi
Wu, Jianhua
Inverted internal limiting membrane flap technique for retinal detachment due to macular holes in high myopia with axial length ≥ 30 mm
title Inverted internal limiting membrane flap technique for retinal detachment due to macular holes in high myopia with axial length ≥ 30 mm
title_full Inverted internal limiting membrane flap technique for retinal detachment due to macular holes in high myopia with axial length ≥ 30 mm
title_fullStr Inverted internal limiting membrane flap technique for retinal detachment due to macular holes in high myopia with axial length ≥ 30 mm
title_full_unstemmed Inverted internal limiting membrane flap technique for retinal detachment due to macular holes in high myopia with axial length ≥ 30 mm
title_short Inverted internal limiting membrane flap technique for retinal detachment due to macular holes in high myopia with axial length ≥ 30 mm
title_sort inverted internal limiting membrane flap technique for retinal detachment due to macular holes in high myopia with axial length ≥ 30 mm
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8917174/
https://www.ncbi.nlm.nih.gov/pubmed/35277581
http://dx.doi.org/10.1038/s41598-022-08277-y
work_keys_str_mv AT xuchangzhong invertedinternallimitingmembraneflaptechniqueforretinaldetachmentduetomacularholesinhighmyopiawithaxiallength30mm
AT fengchao invertedinternallimitingmembraneflaptechniqueforretinaldetachmentduetomacularholesinhighmyopiawithaxiallength30mm
AT hanmengyao invertedinternallimitingmembraneflaptechniqueforretinaldetachmentduetomacularholesinhighmyopiawithaxiallength30mm
AT hejunwen invertedinternallimitingmembraneflaptechniqueforretinaldetachmentduetomacularholesinhighmyopiawithaxiallength30mm
AT zhangrui invertedinternallimitingmembraneflaptechniqueforretinaldetachmentduetomacularholesinhighmyopiawithaxiallength30mm
AT yantao invertedinternallimitingmembraneflaptechniqueforretinaldetachmentduetomacularholesinhighmyopiawithaxiallength30mm
AT lixiangyun invertedinternallimitingmembraneflaptechniqueforretinaldetachmentduetomacularholesinhighmyopiawithaxiallength30mm
AT liuyong invertedinternallimitingmembraneflaptechniqueforretinaldetachmentduetomacularholesinhighmyopiawithaxiallength30mm
AT liyanzi invertedinternallimitingmembraneflaptechniqueforretinaldetachmentduetomacularholesinhighmyopiawithaxiallength30mm
AT wujianhua invertedinternallimitingmembraneflaptechniqueforretinaldetachmentduetomacularholesinhighmyopiawithaxiallength30mm