Cargando…
Diagnostic Performance of Atherosclerotic Carotid Plaque Neovascularization with Contrast-Enhanced Ultrasound: A Meta-Analysis
OBJECTIVES: To evaluate the diagnostic performance of contrast-enhanced ultrasound (CEUS) for atherosclerotic carotid plaque neovascularization. METHODS: The electronic databases like PubMed, Embase, OVID, and Web of Science were used to search for the relevant studies, which are involved in the eva...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8920645/ https://www.ncbi.nlm.nih.gov/pubmed/35295205 http://dx.doi.org/10.1155/2022/7531624 |
_version_ | 1784669169714724864 |
---|---|
author | Dong, Shanshan Hou, Jianzhong Zhang, Caiyun Lu, Guilin Qin, Wenjuan Huang, Lei Zhou, Guangqin |
author_facet | Dong, Shanshan Hou, Jianzhong Zhang, Caiyun Lu, Guilin Qin, Wenjuan Huang, Lei Zhou, Guangqin |
author_sort | Dong, Shanshan |
collection | PubMed |
description | OBJECTIVES: To evaluate the diagnostic performance of contrast-enhanced ultrasound (CEUS) for atherosclerotic carotid plaque neovascularization. METHODS: The electronic databases like PubMed, Embase, OVID, and Web of Science were used to search for the relevant studies, which are involved in the evaluation of the diagnostic parameters of QUS for atherosclerotic carotid plaque neovascularization. Review Manager 5.4 and Stata 14.0 were used to estimate the pooled diagnostic value of CEUS. Forest plots, sensitivity analysis, and Deeks' funnel plots were performed on the included studies. RESULTS: Ten studies eventually met the final inclusion criteria. For diagnostic performance, CUES showed that the pooled values of sensitivity, specificity, positive likelihood odds ratios, negative likelihood odds ratios, and diagnostic odds ratios were 0.83 (95% CI 0.78-0.86), 0.77 (95% CI 0.68-0.84), 3.61 (95% CI 2.59-5.03), 0.23 (95% CI 0.18-0.28), and 16.02 (95% CI 10.02-25.60), respectively. The estimate of the area under curve (AUC) was 0.85 (95% CI 0.82-0.88). CONCLUSION: Our research supported that CEUS had high sensitivity and specificity in the diagnosis of atherosclerotic carotid plaque neovascularization. More high-quality prospective multicenter studies focusing on the accuracy of CEUS for carotid atherosclerotic plaque should be performed to verify our conclusions. |
format | Online Article Text |
id | pubmed-8920645 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-89206452022-03-15 Diagnostic Performance of Atherosclerotic Carotid Plaque Neovascularization with Contrast-Enhanced Ultrasound: A Meta-Analysis Dong, Shanshan Hou, Jianzhong Zhang, Caiyun Lu, Guilin Qin, Wenjuan Huang, Lei Zhou, Guangqin Comput Math Methods Med Research Article OBJECTIVES: To evaluate the diagnostic performance of contrast-enhanced ultrasound (CEUS) for atherosclerotic carotid plaque neovascularization. METHODS: The electronic databases like PubMed, Embase, OVID, and Web of Science were used to search for the relevant studies, which are involved in the evaluation of the diagnostic parameters of QUS for atherosclerotic carotid plaque neovascularization. Review Manager 5.4 and Stata 14.0 were used to estimate the pooled diagnostic value of CEUS. Forest plots, sensitivity analysis, and Deeks' funnel plots were performed on the included studies. RESULTS: Ten studies eventually met the final inclusion criteria. For diagnostic performance, CUES showed that the pooled values of sensitivity, specificity, positive likelihood odds ratios, negative likelihood odds ratios, and diagnostic odds ratios were 0.83 (95% CI 0.78-0.86), 0.77 (95% CI 0.68-0.84), 3.61 (95% CI 2.59-5.03), 0.23 (95% CI 0.18-0.28), and 16.02 (95% CI 10.02-25.60), respectively. The estimate of the area under curve (AUC) was 0.85 (95% CI 0.82-0.88). CONCLUSION: Our research supported that CEUS had high sensitivity and specificity in the diagnosis of atherosclerotic carotid plaque neovascularization. More high-quality prospective multicenter studies focusing on the accuracy of CEUS for carotid atherosclerotic plaque should be performed to verify our conclusions. Hindawi 2022-03-07 /pmc/articles/PMC8920645/ /pubmed/35295205 http://dx.doi.org/10.1155/2022/7531624 Text en Copyright © 2022 Shanshan Dong et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Dong, Shanshan Hou, Jianzhong Zhang, Caiyun Lu, Guilin Qin, Wenjuan Huang, Lei Zhou, Guangqin Diagnostic Performance of Atherosclerotic Carotid Plaque Neovascularization with Contrast-Enhanced Ultrasound: A Meta-Analysis |
title | Diagnostic Performance of Atherosclerotic Carotid Plaque Neovascularization with Contrast-Enhanced Ultrasound: A Meta-Analysis |
title_full | Diagnostic Performance of Atherosclerotic Carotid Plaque Neovascularization with Contrast-Enhanced Ultrasound: A Meta-Analysis |
title_fullStr | Diagnostic Performance of Atherosclerotic Carotid Plaque Neovascularization with Contrast-Enhanced Ultrasound: A Meta-Analysis |
title_full_unstemmed | Diagnostic Performance of Atherosclerotic Carotid Plaque Neovascularization with Contrast-Enhanced Ultrasound: A Meta-Analysis |
title_short | Diagnostic Performance of Atherosclerotic Carotid Plaque Neovascularization with Contrast-Enhanced Ultrasound: A Meta-Analysis |
title_sort | diagnostic performance of atherosclerotic carotid plaque neovascularization with contrast-enhanced ultrasound: a meta-analysis |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8920645/ https://www.ncbi.nlm.nih.gov/pubmed/35295205 http://dx.doi.org/10.1155/2022/7531624 |
work_keys_str_mv | AT dongshanshan diagnosticperformanceofatheroscleroticcarotidplaqueneovascularizationwithcontrastenhancedultrasoundametaanalysis AT houjianzhong diagnosticperformanceofatheroscleroticcarotidplaqueneovascularizationwithcontrastenhancedultrasoundametaanalysis AT zhangcaiyun diagnosticperformanceofatheroscleroticcarotidplaqueneovascularizationwithcontrastenhancedultrasoundametaanalysis AT luguilin diagnosticperformanceofatheroscleroticcarotidplaqueneovascularizationwithcontrastenhancedultrasoundametaanalysis AT qinwenjuan diagnosticperformanceofatheroscleroticcarotidplaqueneovascularizationwithcontrastenhancedultrasoundametaanalysis AT huanglei diagnosticperformanceofatheroscleroticcarotidplaqueneovascularizationwithcontrastenhancedultrasoundametaanalysis AT zhouguangqin diagnosticperformanceofatheroscleroticcarotidplaqueneovascularizationwithcontrastenhancedultrasoundametaanalysis |