Assessment of the measurement of canine and feline serum fibroblast growth factor-23 concentrations by automated chemiluminescence immunoassay
This study compared canine and feline fibroblast growth factor (FGF)-23 concentration measurements between automated chemiluminescence assay (CLEIA) and enzyme-linked immunosorbent assay (ELISA). Seventy serum samples each from dogs and cats were evaluated. FGF-23 measurements by CLEIA significantly...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Japanese Society of Veterinary Science
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8920724/ https://www.ncbi.nlm.nih.gov/pubmed/34980757 http://dx.doi.org/10.1292/jvms.21-0566 |
Sumario: | This study compared canine and feline fibroblast growth factor (FGF)-23 concentration measurements between automated chemiluminescence assay (CLEIA) and enzyme-linked immunosorbent assay (ELISA). Seventy serum samples each from dogs and cats were evaluated. FGF-23 measurements by CLEIA significantly correlated with those of ELISA in both dogs and cats. The Bland–Altman test showed that FGF-23 between CLEIA and ELISA had fixed and proportional biases, respectively, in both dogs and cats. Measurements by CLEIA were lower than those of ELISA, especially in higher serum FGF-23 concentrations. This study showed that FGF-23 concentrations in dogs and cats can be evaluated by automated CLEIA. However, FGF-23 cannot be directly compared between CLEIA and ELISA. |
---|