Assessment of the measurement of canine and feline serum fibroblast growth factor-23 concentrations by automated chemiluminescence immunoassay

This study compared canine and feline fibroblast growth factor (FGF)-23 concentration measurements between automated chemiluminescence assay (CLEIA) and enzyme-linked immunosorbent assay (ELISA). Seventy serum samples each from dogs and cats were evaluated. FGF-23 measurements by CLEIA significantly...

Descripción completa

Detalles Bibliográficos
Autores principales: MIYAKAWA, Hirosumi, HSU, Huai-Hsun, OGAWA, Mizuki, MIYAGAWA, Yuichi, TAKEMURA, Naoyuki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Japanese Society of Veterinary Science 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8920724/
https://www.ncbi.nlm.nih.gov/pubmed/34980757
http://dx.doi.org/10.1292/jvms.21-0566
Descripción
Sumario:This study compared canine and feline fibroblast growth factor (FGF)-23 concentration measurements between automated chemiluminescence assay (CLEIA) and enzyme-linked immunosorbent assay (ELISA). Seventy serum samples each from dogs and cats were evaluated. FGF-23 measurements by CLEIA significantly correlated with those of ELISA in both dogs and cats. The Bland–Altman test showed that FGF-23 between CLEIA and ELISA had fixed and proportional biases, respectively, in both dogs and cats. Measurements by CLEIA were lower than those of ELISA, especially in higher serum FGF-23 concentrations. This study showed that FGF-23 concentrations in dogs and cats can be evaluated by automated CLEIA. However, FGF-23 cannot be directly compared between CLEIA and ELISA.