PURPOSE: The aim of this study was to compare the enucleation performances of four different types of laser devices in an ex-vivo experiment: a novel, pulsed Tm:YAG solid-state laser evaluation model (p-Tm:YAG), chopped thulium fibre laser (TFL), low-power Ho:YAG laser (LP-Ho:YAG), and a high-power...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8921029/ https://www.ncbi.nlm.nih.gov/pubmed/34477954 http://dx.doi.org/10.1007/s00345-021-03825-z |
Sumario: | PURPOSE: The aim of this study was to compare the enucleation performances of four different types of laser devices in an ex-vivo experiment: a novel, pulsed Tm:YAG solid-state laser evaluation model (p-Tm:YAG), chopped thulium fibre laser (TFL), low-power Ho:YAG laser (LP-Ho:YAG), and a high-power Ho:YAG laser (HP-Ho:YAG). METHODS: Our primary aim was to endoscopically separate the fascial layers of a porcine belly using laser fibres within a time period of 60 s. The size of a “tissue pocket” was assessed numerically. The enucleation characteristics reflecting the surgeon’s experience were evaluated via the NASA Task Load Index (TLX) questionnaire and a questionnaire based on Likert scale. RESULTS: HP-Ho:YAG achieved with the available laser settings the largest overall “tissue pocket” (31.5 cm(2)) followed by p-Tm:YAG (15 cm(2)), TFL (12 cm(2)), and LP-Ho:YAG (6 cm(2)). The coagulation performances of p-Tm:YAG and TFL were rated the best. In the performance evaluation by the Likert questionnaire, HP-Ho:YAG (average score of 4.06) was rated highest, followed by p-Tm:YAG (3.94), TFL (3.38), and LP-Ho:YAG (3.25). The evaluation of the NASA-TLX performance questionnaire revealed average scores for HP-Ho:YAG, LP-Ho:YAG, TFL and p-Tm:YAG of 4.38, 4.09, 3.92 and 3.90, respectively. CONCLUSION: We are the first to compare different laser devices and settings in an ex-vivo study. We found that the surgeons were most satisfied with the HP-Ho:YAG laser device, followed by the p-Tm:YAG. These findings could be highly relevant for future research and for the practical utilisation of laser systems in endourology. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00345-021-03825-z. |
---|