Cargando…

Synthetic MRI with T(2)-based Water Suppression to Reduce Hyperintense Artifacts due to CSF–Partial Volume Effects in the Brain

PURPOSE: Our purpose was to assess our proposed new synthetic MRI (synMRI) technique, combined with T(2)-based water suppression (T(2)wsup), to reduce cerebral spinal fluid (CSF)–partial volume effects (PVEs). These PVEs are problematic in the T(2)-weighted fluid-attenuation inversion recovery (FLAI...

Descripción completa

Detalles Bibliográficos
Autores principales: Kimura, Tokunori, Yamashita, Kousuke, Fukatsu, Kouta
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Japanese Society for Magnetic Resonance in Medicine 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8922351/
https://www.ncbi.nlm.nih.gov/pubmed/33071246
http://dx.doi.org/10.2463/mrms.mp.2020-0044
_version_ 1784669506995486720
author Kimura, Tokunori
Yamashita, Kousuke
Fukatsu, Kouta
author_facet Kimura, Tokunori
Yamashita, Kousuke
Fukatsu, Kouta
author_sort Kimura, Tokunori
collection PubMed
description PURPOSE: Our purpose was to assess our proposed new synthetic MRI (synMRI) technique, combined with T(2)-based water suppression (T(2)wsup), to reduce cerebral spinal fluid (CSF)–partial volume effects (PVEs). These PVEs are problematic in the T(2)-weighted fluid-attenuation inversion recovery (FLAIR) images obtained by conventional synMRI techniques. METHODS: Our T(2)wsup was achieved by subtracting additionally acquired long TE spin echo (SE) images of water signals dominant from the originally acquired images after T(2) decay correction and a masking on the long TE image using the water volume (V(w)) map to preserve tissue SNR, followed by quantitative mapping and then calculation of the synthetic images. A simulation study based on a two-compartment model including tissue and water in a voxel and a volunteer MR study were performed to assess our proposed method. Parameters of long TE and a threshold value in the masking were assessed and optimized experimentally. Quantitative parameter maps of standard and with T(2)wsup were generated, then wsup-synthetic FLAIR and SE images were calculated using those suitable combinations and compared. RESULTS: Our simulation clarified that the CSF–PVE artifacts in the standard synthetic FLAIR increase T(2) as the water volume increases in a voxel, and the volunteer MR brain study demonstrated that the hyperintense artifacts on synthetic images were reduced to < 10% of V(w) in those with the standard synMRI while keeping the tissue SNR by selecting optimal masking parameters on additional long TE images of TE = 300 ms. In addition, the wsup-synthetic SE provided better gray-white matter contrasts compared with the wsup-synthetic FLAIR while keeping CSF suppression. CONCLUSION: Our proposed T(2)wsup-synMRI technique makes it easy to reduce the CSF–PVE artifacts problematic in the synthetic FLAIR images using the current synMRI technique by adding long TE images and simple processing. Although further optimizations in data acquisition and processing techniques are required before actual clinical use, we expect our technique to become clinically useful.
format Online
Article
Text
id pubmed-8922351
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Japanese Society for Magnetic Resonance in Medicine
record_format MEDLINE/PubMed
spelling pubmed-89223512022-03-28 Synthetic MRI with T(2)-based Water Suppression to Reduce Hyperintense Artifacts due to CSF–Partial Volume Effects in the Brain Kimura, Tokunori Yamashita, Kousuke Fukatsu, Kouta Magn Reson Med Sci Major Paper PURPOSE: Our purpose was to assess our proposed new synthetic MRI (synMRI) technique, combined with T(2)-based water suppression (T(2)wsup), to reduce cerebral spinal fluid (CSF)–partial volume effects (PVEs). These PVEs are problematic in the T(2)-weighted fluid-attenuation inversion recovery (FLAIR) images obtained by conventional synMRI techniques. METHODS: Our T(2)wsup was achieved by subtracting additionally acquired long TE spin echo (SE) images of water signals dominant from the originally acquired images after T(2) decay correction and a masking on the long TE image using the water volume (V(w)) map to preserve tissue SNR, followed by quantitative mapping and then calculation of the synthetic images. A simulation study based on a two-compartment model including tissue and water in a voxel and a volunteer MR study were performed to assess our proposed method. Parameters of long TE and a threshold value in the masking were assessed and optimized experimentally. Quantitative parameter maps of standard and with T(2)wsup were generated, then wsup-synthetic FLAIR and SE images were calculated using those suitable combinations and compared. RESULTS: Our simulation clarified that the CSF–PVE artifacts in the standard synthetic FLAIR increase T(2) as the water volume increases in a voxel, and the volunteer MR brain study demonstrated that the hyperintense artifacts on synthetic images were reduced to < 10% of V(w) in those with the standard synMRI while keeping the tissue SNR by selecting optimal masking parameters on additional long TE images of TE = 300 ms. In addition, the wsup-synthetic SE provided better gray-white matter contrasts compared with the wsup-synthetic FLAIR while keeping CSF suppression. CONCLUSION: Our proposed T(2)wsup-synMRI technique makes it easy to reduce the CSF–PVE artifacts problematic in the synthetic FLAIR images using the current synMRI technique by adding long TE images and simple processing. Although further optimizations in data acquisition and processing techniques are required before actual clinical use, we expect our technique to become clinically useful. Japanese Society for Magnetic Resonance in Medicine 2020-10-16 /pmc/articles/PMC8922351/ /pubmed/33071246 http://dx.doi.org/10.2463/mrms.mp.2020-0044 Text en © 2020 Japanese Society for Magnetic Resonance in Medicine https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/)
spellingShingle Major Paper
Kimura, Tokunori
Yamashita, Kousuke
Fukatsu, Kouta
Synthetic MRI with T(2)-based Water Suppression to Reduce Hyperintense Artifacts due to CSF–Partial Volume Effects in the Brain
title Synthetic MRI with T(2)-based Water Suppression to Reduce Hyperintense Artifacts due to CSF–Partial Volume Effects in the Brain
title_full Synthetic MRI with T(2)-based Water Suppression to Reduce Hyperintense Artifacts due to CSF–Partial Volume Effects in the Brain
title_fullStr Synthetic MRI with T(2)-based Water Suppression to Reduce Hyperintense Artifacts due to CSF–Partial Volume Effects in the Brain
title_full_unstemmed Synthetic MRI with T(2)-based Water Suppression to Reduce Hyperintense Artifacts due to CSF–Partial Volume Effects in the Brain
title_short Synthetic MRI with T(2)-based Water Suppression to Reduce Hyperintense Artifacts due to CSF–Partial Volume Effects in the Brain
title_sort synthetic mri with t(2)-based water suppression to reduce hyperintense artifacts due to csf–partial volume effects in the brain
topic Major Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8922351/
https://www.ncbi.nlm.nih.gov/pubmed/33071246
http://dx.doi.org/10.2463/mrms.mp.2020-0044
work_keys_str_mv AT kimuratokunori syntheticmriwitht2basedwatersuppressiontoreducehyperintenseartifactsduetocsfpartialvolumeeffectsinthebrain
AT yamashitakousuke syntheticmriwitht2basedwatersuppressiontoreducehyperintenseartifactsduetocsfpartialvolumeeffectsinthebrain
AT fukatsukouta syntheticmriwitht2basedwatersuppressiontoreducehyperintenseartifactsduetocsfpartialvolumeeffectsinthebrain