Cargando…

A review of the microtremor horizontal-to-vertical spectral ratio (MHVSR) method

The single-station microtremor horizontal-to-vertical spectral ratio (MHVSR) method was initially proposed to retrieve the site amplification function and its resonance frequencies produced by unconsolidated sediments overlying high-velocity bedrock. Presently, MHVSR measurements are predominantly c...

Descripción completa

Detalles Bibliográficos
Autores principales: Molnar, S., Sirohey, A., Assaf, J., Bard, P.-Y., Castellaro, S., Cornou, C., Cox, B., Guillier, B., Hassani, B., Kawase, H., Matsushima, S., Sánchez-Sesma, F. J., Yong, A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Netherlands 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8926454/
https://www.ncbi.nlm.nih.gov/pubmed/35313617
http://dx.doi.org/10.1007/s10950-021-10062-9
_version_ 1784670240310820864
author Molnar, S.
Sirohey, A.
Assaf, J.
Bard, P.-Y.
Castellaro, S.
Cornou, C.
Cox, B.
Guillier, B.
Hassani, B.
Kawase, H.
Matsushima, S.
Sánchez-Sesma, F. J.
Yong, A.
author_facet Molnar, S.
Sirohey, A.
Assaf, J.
Bard, P.-Y.
Castellaro, S.
Cornou, C.
Cox, B.
Guillier, B.
Hassani, B.
Kawase, H.
Matsushima, S.
Sánchez-Sesma, F. J.
Yong, A.
author_sort Molnar, S.
collection PubMed
description The single-station microtremor horizontal-to-vertical spectral ratio (MHVSR) method was initially proposed to retrieve the site amplification function and its resonance frequencies produced by unconsolidated sediments overlying high-velocity bedrock. Presently, MHVSR measurements are predominantly conducted to obtain an estimate of the fundamental site frequency at sites where a strong subsurface impedance contrast exists. Of the earthquake site characterization methods presented in this special issue, the MHVSR method is the furthest behind in terms of consensus towards standardized guidelines and commercial use. The greatest challenges to an international standardization of MHVSR acquisition and analysis are (1) the what — the underlying composition of the microtremor wavefield is site-dependent, and thus, the appropriate theoretical (forward) model for inversion is still debated; and (2) the how — many factors and options are involved in the data acquisition, processing, and interpretation stages. This paper reviews briefly a historical development of the MHVSR technique and the physical basis of an MHVSR (the what). We then summarize recommendations for MHVSR acquisition and analysis (the how). Specific sections address MHVSR interpretation and uncertainty assessment.
format Online
Article
Text
id pubmed-8926454
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-89264542022-03-17 A review of the microtremor horizontal-to-vertical spectral ratio (MHVSR) method Molnar, S. Sirohey, A. Assaf, J. Bard, P.-Y. Castellaro, S. Cornou, C. Cox, B. Guillier, B. Hassani, B. Kawase, H. Matsushima, S. Sánchez-Sesma, F. J. Yong, A. J Seismol Original Article The single-station microtremor horizontal-to-vertical spectral ratio (MHVSR) method was initially proposed to retrieve the site amplification function and its resonance frequencies produced by unconsolidated sediments overlying high-velocity bedrock. Presently, MHVSR measurements are predominantly conducted to obtain an estimate of the fundamental site frequency at sites where a strong subsurface impedance contrast exists. Of the earthquake site characterization methods presented in this special issue, the MHVSR method is the furthest behind in terms of consensus towards standardized guidelines and commercial use. The greatest challenges to an international standardization of MHVSR acquisition and analysis are (1) the what — the underlying composition of the microtremor wavefield is site-dependent, and thus, the appropriate theoretical (forward) model for inversion is still debated; and (2) the how — many factors and options are involved in the data acquisition, processing, and interpretation stages. This paper reviews briefly a historical development of the MHVSR technique and the physical basis of an MHVSR (the what). We then summarize recommendations for MHVSR acquisition and analysis (the how). Specific sections address MHVSR interpretation and uncertainty assessment. Springer Netherlands 2022-03-16 2022 /pmc/articles/PMC8926454/ /pubmed/35313617 http://dx.doi.org/10.1007/s10950-021-10062-9 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Molnar, S.
Sirohey, A.
Assaf, J.
Bard, P.-Y.
Castellaro, S.
Cornou, C.
Cox, B.
Guillier, B.
Hassani, B.
Kawase, H.
Matsushima, S.
Sánchez-Sesma, F. J.
Yong, A.
A review of the microtremor horizontal-to-vertical spectral ratio (MHVSR) method
title A review of the microtremor horizontal-to-vertical spectral ratio (MHVSR) method
title_full A review of the microtremor horizontal-to-vertical spectral ratio (MHVSR) method
title_fullStr A review of the microtremor horizontal-to-vertical spectral ratio (MHVSR) method
title_full_unstemmed A review of the microtremor horizontal-to-vertical spectral ratio (MHVSR) method
title_short A review of the microtremor horizontal-to-vertical spectral ratio (MHVSR) method
title_sort review of the microtremor horizontal-to-vertical spectral ratio (mhvsr) method
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8926454/
https://www.ncbi.nlm.nih.gov/pubmed/35313617
http://dx.doi.org/10.1007/s10950-021-10062-9
work_keys_str_mv AT molnars areviewofthemicrotremorhorizontaltoverticalspectralratiomhvsrmethod
AT siroheya areviewofthemicrotremorhorizontaltoverticalspectralratiomhvsrmethod
AT assafj areviewofthemicrotremorhorizontaltoverticalspectralratiomhvsrmethod
AT bardpy areviewofthemicrotremorhorizontaltoverticalspectralratiomhvsrmethod
AT castellaros areviewofthemicrotremorhorizontaltoverticalspectralratiomhvsrmethod
AT cornouc areviewofthemicrotremorhorizontaltoverticalspectralratiomhvsrmethod
AT coxb areviewofthemicrotremorhorizontaltoverticalspectralratiomhvsrmethod
AT guillierb areviewofthemicrotremorhorizontaltoverticalspectralratiomhvsrmethod
AT hassanib areviewofthemicrotremorhorizontaltoverticalspectralratiomhvsrmethod
AT kawaseh areviewofthemicrotremorhorizontaltoverticalspectralratiomhvsrmethod
AT matsushimas areviewofthemicrotremorhorizontaltoverticalspectralratiomhvsrmethod
AT sanchezsesmafj areviewofthemicrotremorhorizontaltoverticalspectralratiomhvsrmethod
AT yonga areviewofthemicrotremorhorizontaltoverticalspectralratiomhvsrmethod
AT molnars reviewofthemicrotremorhorizontaltoverticalspectralratiomhvsrmethod
AT siroheya reviewofthemicrotremorhorizontaltoverticalspectralratiomhvsrmethod
AT assafj reviewofthemicrotremorhorizontaltoverticalspectralratiomhvsrmethod
AT bardpy reviewofthemicrotremorhorizontaltoverticalspectralratiomhvsrmethod
AT castellaros reviewofthemicrotremorhorizontaltoverticalspectralratiomhvsrmethod
AT cornouc reviewofthemicrotremorhorizontaltoverticalspectralratiomhvsrmethod
AT coxb reviewofthemicrotremorhorizontaltoverticalspectralratiomhvsrmethod
AT guillierb reviewofthemicrotremorhorizontaltoverticalspectralratiomhvsrmethod
AT hassanib reviewofthemicrotremorhorizontaltoverticalspectralratiomhvsrmethod
AT kawaseh reviewofthemicrotremorhorizontaltoverticalspectralratiomhvsrmethod
AT matsushimas reviewofthemicrotremorhorizontaltoverticalspectralratiomhvsrmethod
AT sanchezsesmafj reviewofthemicrotremorhorizontaltoverticalspectralratiomhvsrmethod
AT yonga reviewofthemicrotremorhorizontaltoverticalspectralratiomhvsrmethod