Cargando…
Measuring distance from the incisors to the esophageal cancer by FDG PET/CT: endoscopy as the reference
BACKGROUND: Using endoscopy as the reference, this study evaluated the accuracy of 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) in measuring distance from the incisors to the PET detectable esophageal cancer. If there is high concordance between endoscopic and...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8928607/ https://www.ncbi.nlm.nih.gov/pubmed/35300618 http://dx.doi.org/10.1186/s12876-022-02206-z |
Sumario: | BACKGROUND: Using endoscopy as the reference, this study evaluated the accuracy of 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) in measuring distance from the incisors to the PET detectable esophageal cancer. If there is high concordance between endoscopic and PET measurements, our results may provide a basis to use FDG PET/CT in cooperation with endoscopic measurement to localize those PET/CT and CT undetectable esophageal tumors for radiotherapy planning. MATERIALS: Esophageal cancer patients with pretreatment endoscopy and FDG PET/CT detectable esophageal tumors were recruited retrospectively. The distances from the incisors to the proximal esophageal tumor margins were determined by endoscopy and by the sagittal images of FDG PET/CT. The endoscopic measurement was used as the comparative reference. A nuclear medicine doctor and a radiation oncologist each performed the FDG PET/CT measurement twice for every patient. We analyzed the differences in these measurements, and assessed agreement and reproducibility of the results by the intraclass correlation coefficient (ICC). RESULTS: Thirty-four patients, with 35 esophageal tumors, were included. By endoscopy and FDG PET/CT, the mean distances from the incisors to the proximal esophageal tumor margin were 27.3 ± 6.4 cm (range 17.1–40.0 cm) and 26.8 ± 6.3 cm (range 15.7–41.3 cm), respectively. The mean absolute differences between the endoscopic and four FDG PET/CT measurements ranged from 1.129 to 1.289 cm (SD: 0.98–1.19). The measurement agreement between FDG PET/CT and endoscopy by ICC was between 0.962 and 0.971. The intra- and interobserver reproducibilities of the two readers were excellent (intraobserver ICC: 0.985, 0.996; interobserver ICC: 0.976–0.984). CONCLUSIONS: FDG PET/CT was in high agreement with endoscopy in measuring the distance from the incisors to the proximal esophageal tumor margin. For FDG PET/CT and CT undetectable esophageal cancer, incorporation of the endoscopic measurement with PET/CT might be a way for making radiotherapy plan. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12876-022-02206-z. |
---|