Device-based Optimization of Cardiac Resynchronization—One Size Does Not Fit All
We report on a 72-year-old female patient who was sent to our clinic for evaluation of a biventricular intracardiac defibrillator (BIV-ICD). The patient was diagnosed with ischemic cardiomyopathy and showed a persistently low ejection fraction in the range of 20%–25% with New York Heart Association...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MediaSphere Medical
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8930014/ https://www.ncbi.nlm.nih.gov/pubmed/35317210 http://dx.doi.org/10.19102/icrm.2022.130307 |
_version_ | 1784670969590185984 |
---|---|
author | Rashid, Wasim Kichloo, Asim Kanjwal, Khalil |
author_facet | Rashid, Wasim Kichloo, Asim Kanjwal, Khalil |
author_sort | Rashid, Wasim |
collection | PubMed |
description | We report on a 72-year-old female patient who was sent to our clinic for evaluation of a biventricular intracardiac defibrillator (BIV-ICD). The patient was diagnosed with ischemic cardiomyopathy and showed a persistently low ejection fraction in the range of 20%–25% with New York Heart Association class III heart failure symptoms despite being on guideline-directed medical therapy, including a β-blocker and a combination of sacubitril and valsartan, for >3 months. In addition, the patient had underlying right bundle branch block (RBBB) with a QRS duration of 160 ms. The device was programmed with a Sync-AV algorithm on with nominal settings (delta of −50 ms). The thresholds and lead impedances were acceptable. Electrocardiography was performed in the postoperative period, showing persistent RBBB similar to the baseline electrocardiogram without much QRS narrowing. In this report, we discuss the mechanism and troubleshooting of this problem. |
format | Online Article Text |
id | pubmed-8930014 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MediaSphere Medical |
record_format | MEDLINE/PubMed |
spelling | pubmed-89300142022-03-21 Device-based Optimization of Cardiac Resynchronization—One Size Does Not Fit All Rashid, Wasim Kichloo, Asim Kanjwal, Khalil J Innov Card Rhythm Manag Case Report We report on a 72-year-old female patient who was sent to our clinic for evaluation of a biventricular intracardiac defibrillator (BIV-ICD). The patient was diagnosed with ischemic cardiomyopathy and showed a persistently low ejection fraction in the range of 20%–25% with New York Heart Association class III heart failure symptoms despite being on guideline-directed medical therapy, including a β-blocker and a combination of sacubitril and valsartan, for >3 months. In addition, the patient had underlying right bundle branch block (RBBB) with a QRS duration of 160 ms. The device was programmed with a Sync-AV algorithm on with nominal settings (delta of −50 ms). The thresholds and lead impedances were acceptable. Electrocardiography was performed in the postoperative period, showing persistent RBBB similar to the baseline electrocardiogram without much QRS narrowing. In this report, we discuss the mechanism and troubleshooting of this problem. MediaSphere Medical 2022-03-15 /pmc/articles/PMC8930014/ /pubmed/35317210 http://dx.doi.org/10.19102/icrm.2022.130307 Text en Copyright: © 2022 Innovations in Cardiac Rhythm Management https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Rashid, Wasim Kichloo, Asim Kanjwal, Khalil Device-based Optimization of Cardiac Resynchronization—One Size Does Not Fit All |
title | Device-based Optimization of Cardiac Resynchronization—One Size Does Not Fit All |
title_full | Device-based Optimization of Cardiac Resynchronization—One Size Does Not Fit All |
title_fullStr | Device-based Optimization of Cardiac Resynchronization—One Size Does Not Fit All |
title_full_unstemmed | Device-based Optimization of Cardiac Resynchronization—One Size Does Not Fit All |
title_short | Device-based Optimization of Cardiac Resynchronization—One Size Does Not Fit All |
title_sort | device-based optimization of cardiac resynchronization—one size does not fit all |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8930014/ https://www.ncbi.nlm.nih.gov/pubmed/35317210 http://dx.doi.org/10.19102/icrm.2022.130307 |
work_keys_str_mv | AT rashidwasim devicebasedoptimizationofcardiacresynchronizationonesizedoesnotfitall AT kichlooasim devicebasedoptimizationofcardiacresynchronizationonesizedoesnotfitall AT kanjwalkhalil devicebasedoptimizationofcardiacresynchronizationonesizedoesnotfitall |