Device-based Optimization of Cardiac Resynchronization—One Size Does Not Fit All

We report on a 72-year-old female patient who was sent to our clinic for evaluation of a biventricular intracardiac defibrillator (BIV-ICD). The patient was diagnosed with ischemic cardiomyopathy and showed a persistently low ejection fraction in the range of 20%–25% with New York Heart Association...

Descripción completa

Detalles Bibliográficos
Autores principales: Rashid, Wasim, Kichloo, Asim, Kanjwal, Khalil
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MediaSphere Medical 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8930014/
https://www.ncbi.nlm.nih.gov/pubmed/35317210
http://dx.doi.org/10.19102/icrm.2022.130307
_version_ 1784670969590185984
author Rashid, Wasim
Kichloo, Asim
Kanjwal, Khalil
author_facet Rashid, Wasim
Kichloo, Asim
Kanjwal, Khalil
author_sort Rashid, Wasim
collection PubMed
description We report on a 72-year-old female patient who was sent to our clinic for evaluation of a biventricular intracardiac defibrillator (BIV-ICD). The patient was diagnosed with ischemic cardiomyopathy and showed a persistently low ejection fraction in the range of 20%–25% with New York Heart Association class III heart failure symptoms despite being on guideline-directed medical therapy, including a β-blocker and a combination of sacubitril and valsartan, for >3 months. In addition, the patient had underlying right bundle branch block (RBBB) with a QRS duration of 160 ms. The device was programmed with a Sync-AV algorithm on with nominal settings (delta of −50 ms). The thresholds and lead impedances were acceptable. Electrocardiography was performed in the postoperative period, showing persistent RBBB similar to the baseline electrocardiogram without much QRS narrowing. In this report, we discuss the mechanism and troubleshooting of this problem.
format Online
Article
Text
id pubmed-8930014
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MediaSphere Medical
record_format MEDLINE/PubMed
spelling pubmed-89300142022-03-21 Device-based Optimization of Cardiac Resynchronization—One Size Does Not Fit All Rashid, Wasim Kichloo, Asim Kanjwal, Khalil J Innov Card Rhythm Manag Case Report We report on a 72-year-old female patient who was sent to our clinic for evaluation of a biventricular intracardiac defibrillator (BIV-ICD). The patient was diagnosed with ischemic cardiomyopathy and showed a persistently low ejection fraction in the range of 20%–25% with New York Heart Association class III heart failure symptoms despite being on guideline-directed medical therapy, including a β-blocker and a combination of sacubitril and valsartan, for >3 months. In addition, the patient had underlying right bundle branch block (RBBB) with a QRS duration of 160 ms. The device was programmed with a Sync-AV algorithm on with nominal settings (delta of −50 ms). The thresholds and lead impedances were acceptable. Electrocardiography was performed in the postoperative period, showing persistent RBBB similar to the baseline electrocardiogram without much QRS narrowing. In this report, we discuss the mechanism and troubleshooting of this problem. MediaSphere Medical 2022-03-15 /pmc/articles/PMC8930014/ /pubmed/35317210 http://dx.doi.org/10.19102/icrm.2022.130307 Text en Copyright: © 2022 Innovations in Cardiac Rhythm Management https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Rashid, Wasim
Kichloo, Asim
Kanjwal, Khalil
Device-based Optimization of Cardiac Resynchronization—One Size Does Not Fit All
title Device-based Optimization of Cardiac Resynchronization—One Size Does Not Fit All
title_full Device-based Optimization of Cardiac Resynchronization—One Size Does Not Fit All
title_fullStr Device-based Optimization of Cardiac Resynchronization—One Size Does Not Fit All
title_full_unstemmed Device-based Optimization of Cardiac Resynchronization—One Size Does Not Fit All
title_short Device-based Optimization of Cardiac Resynchronization—One Size Does Not Fit All
title_sort device-based optimization of cardiac resynchronization—one size does not fit all
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8930014/
https://www.ncbi.nlm.nih.gov/pubmed/35317210
http://dx.doi.org/10.19102/icrm.2022.130307
work_keys_str_mv AT rashidwasim devicebasedoptimizationofcardiacresynchronizationonesizedoesnotfitall
AT kichlooasim devicebasedoptimizationofcardiacresynchronizationonesizedoesnotfitall
AT kanjwalkhalil devicebasedoptimizationofcardiacresynchronizationonesizedoesnotfitall