Cargando…

Assessment of peripheral artery disease risk in building construction workers by Ankle-Brachial index measurement with automated oscillometric and hand-held Doppler device

BACKGROUND: Peripheral arterial disease (PAD) remains underdiagnosed, partly because of the limitations of the Doppler ankle-brachial index (ABI) with regards to equipment, training, and time constraints. AIMS: To compare the accuracy and validity of automated oscillometric ABI measurement in detect...

Descripción completa

Detalles Bibliográficos
Autores principales: Verma, Manish K., Gangwar, Vibha, Jasrotia, Rajani B., John, Nitin A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8930156/
https://www.ncbi.nlm.nih.gov/pubmed/35309627
http://dx.doi.org/10.4103/jfmpc.jfmpc_102_21
_version_ 1784671000112136192
author Verma, Manish K.
Gangwar, Vibha
Jasrotia, Rajani B.
John, Nitin A.
author_facet Verma, Manish K.
Gangwar, Vibha
Jasrotia, Rajani B.
John, Nitin A.
author_sort Verma, Manish K.
collection PubMed
description BACKGROUND: Peripheral arterial disease (PAD) remains underdiagnosed, partly because of the limitations of the Doppler ankle-brachial index (ABI) with regards to equipment, training, and time constraints. AIMS: To compare the accuracy and validity of automated oscillometric ABI measurement in detecting PAD in primary care settings against a gold standard Doppler device. SETTINGS AND DESIGN: A cross-sectional observational study was conducted at the physiology department, Dr. Ram Manohar Lohia Institute of Medical Sciences (DrRMLIMS), Lucknow. METHODS AND MATERIAL: A total of 200 male building construction workers of all types of age groups between 20 and 40 years were recruited. The ABI measurement was performed using the Watch BP Office and hand-held HI.dop, BT-200 Vascular Doppler device. STATISTICAL ANALYSIS USED: The Bland-Altman plot and receiver operator characteristics (ROC) curve were determined to analyze the agreement between the two methods. For the reliability of the test, Pearson’s correlation with linear regression was done and the intraclass correlation (ICC) coefficient was calculated. RESULTS: The mean ABI (Osc) and ABI (Dop) were 1.13 ± 0.09 and 1.06 ± 0.08, respectively. The ABI (Dop) and ABI (Osc) methods were highly correlated Pearson’s correlation coefficient of 0.96 with 95% confidence interval (CI) ranges between 0.985 and 1.066 (P < 0.001). On linear regression analysis, the ABI (Dop) predicted ABI (Osc) 92.6% correctly. The paired mean difference between the two measuring devices was 0.07 (95% CI = −0.03 to −0.12). At 0.90 cut-off value of diagnosing PAD, the sensitivity is 50%, specificity 100%, positive predictive value 100%, and negative predictive value 97% by an oscillometric automated device. CONCLUSION: Our finding suggested that ABI measurement by the automated oscillometric device is reliable, free of examiner bias, and less time-consuming.
format Online
Article
Text
id pubmed-8930156
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-89301562022-03-18 Assessment of peripheral artery disease risk in building construction workers by Ankle-Brachial index measurement with automated oscillometric and hand-held Doppler device Verma, Manish K. Gangwar, Vibha Jasrotia, Rajani B. John, Nitin A. J Family Med Prim Care Original Article BACKGROUND: Peripheral arterial disease (PAD) remains underdiagnosed, partly because of the limitations of the Doppler ankle-brachial index (ABI) with regards to equipment, training, and time constraints. AIMS: To compare the accuracy and validity of automated oscillometric ABI measurement in detecting PAD in primary care settings against a gold standard Doppler device. SETTINGS AND DESIGN: A cross-sectional observational study was conducted at the physiology department, Dr. Ram Manohar Lohia Institute of Medical Sciences (DrRMLIMS), Lucknow. METHODS AND MATERIAL: A total of 200 male building construction workers of all types of age groups between 20 and 40 years were recruited. The ABI measurement was performed using the Watch BP Office and hand-held HI.dop, BT-200 Vascular Doppler device. STATISTICAL ANALYSIS USED: The Bland-Altman plot and receiver operator characteristics (ROC) curve were determined to analyze the agreement between the two methods. For the reliability of the test, Pearson’s correlation with linear regression was done and the intraclass correlation (ICC) coefficient was calculated. RESULTS: The mean ABI (Osc) and ABI (Dop) were 1.13 ± 0.09 and 1.06 ± 0.08, respectively. The ABI (Dop) and ABI (Osc) methods were highly correlated Pearson’s correlation coefficient of 0.96 with 95% confidence interval (CI) ranges between 0.985 and 1.066 (P < 0.001). On linear regression analysis, the ABI (Dop) predicted ABI (Osc) 92.6% correctly. The paired mean difference between the two measuring devices was 0.07 (95% CI = −0.03 to −0.12). At 0.90 cut-off value of diagnosing PAD, the sensitivity is 50%, specificity 100%, positive predictive value 100%, and negative predictive value 97% by an oscillometric automated device. CONCLUSION: Our finding suggested that ABI measurement by the automated oscillometric device is reliable, free of examiner bias, and less time-consuming. Wolters Kluwer - Medknow 2022-01 2022-01-31 /pmc/articles/PMC8930156/ /pubmed/35309627 http://dx.doi.org/10.4103/jfmpc.jfmpc_102_21 Text en Copyright: © 2022 Journal of Family Medicine and Primary Care https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Verma, Manish K.
Gangwar, Vibha
Jasrotia, Rajani B.
John, Nitin A.
Assessment of peripheral artery disease risk in building construction workers by Ankle-Brachial index measurement with automated oscillometric and hand-held Doppler device
title Assessment of peripheral artery disease risk in building construction workers by Ankle-Brachial index measurement with automated oscillometric and hand-held Doppler device
title_full Assessment of peripheral artery disease risk in building construction workers by Ankle-Brachial index measurement with automated oscillometric and hand-held Doppler device
title_fullStr Assessment of peripheral artery disease risk in building construction workers by Ankle-Brachial index measurement with automated oscillometric and hand-held Doppler device
title_full_unstemmed Assessment of peripheral artery disease risk in building construction workers by Ankle-Brachial index measurement with automated oscillometric and hand-held Doppler device
title_short Assessment of peripheral artery disease risk in building construction workers by Ankle-Brachial index measurement with automated oscillometric and hand-held Doppler device
title_sort assessment of peripheral artery disease risk in building construction workers by ankle-brachial index measurement with automated oscillometric and hand-held doppler device
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8930156/
https://www.ncbi.nlm.nih.gov/pubmed/35309627
http://dx.doi.org/10.4103/jfmpc.jfmpc_102_21
work_keys_str_mv AT vermamanishk assessmentofperipheralarterydiseaseriskinbuildingconstructionworkersbyanklebrachialindexmeasurementwithautomatedoscillometricandhandhelddopplerdevice
AT gangwarvibha assessmentofperipheralarterydiseaseriskinbuildingconstructionworkersbyanklebrachialindexmeasurementwithautomatedoscillometricandhandhelddopplerdevice
AT jasrotiarajanib assessmentofperipheralarterydiseaseriskinbuildingconstructionworkersbyanklebrachialindexmeasurementwithautomatedoscillometricandhandhelddopplerdevice
AT johnnitina assessmentofperipheralarterydiseaseriskinbuildingconstructionworkersbyanklebrachialindexmeasurementwithautomatedoscillometricandhandhelddopplerdevice