Cargando…

Strategies for the Long-Term Preservation of Site for Future Implantation of Cardiac Implantable Electronic Devices (CIEDs): Two Decades of Experience

Introduction Implantation of cardiac implantable electronic devices (CIEDs) is an art of science. As the volume of implantation has increased worldwide, so has the rate of complications. Infection, fibrosis, lead and device erosion, lead displacement, right ventricle perforation, lead fracture, and...

Descripción completa

Detalles Bibliográficos
Autores principales: Shah, Bakhtawar, Saidullah, Shahab, Aamer Niaz, Muhammad, Zaman, Farrukh, Parveen, Zahida, Ghazanfar, Aamir, Mumtaz, Hassan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8933269/
https://www.ncbi.nlm.nih.gov/pubmed/35350505
http://dx.doi.org/10.7759/cureus.22259
_version_ 1784671611038728192
author Shah, Bakhtawar
Saidullah, Shahab
Aamer Niaz, Muhammad
Zaman, Farrukh
Parveen, Zahida
Ghazanfar, Aamir
Mumtaz, Hassan
author_facet Shah, Bakhtawar
Saidullah, Shahab
Aamer Niaz, Muhammad
Zaman, Farrukh
Parveen, Zahida
Ghazanfar, Aamir
Mumtaz, Hassan
author_sort Shah, Bakhtawar
collection PubMed
description Introduction Implantation of cardiac implantable electronic devices (CIEDs) is an art of science. As the volume of implantation has increased worldwide, so has the rate of complications. Infection, fibrosis, lead and device erosion, lead displacement, right ventricle perforation, lead fracture, and insulation break are the common complications in the implantation process. This exposes the patient for reopening and threatens the implantation for further complication due to infection, fibrosis of veins, failure to retrieve the implanted wire, and failure to re-implant the device on the same site. We slightly changed our implantation technique to preserve the implantation site for future implantation and reduce the rate of complication in the index implantation. Methods This randomized control trial was conducted from January 2016 to September 2019 at Hayatabad Medical Complex Peshawar, Pakistan. A consecutive sampling technique was used to obtain a sample size of 602 patients keeping a 95% confidence interval and a 5% margin error. We adopted a strategy to take prick, for implantation of devices, inside the pocket, which reduces the number of sutures, hastens the procedure, prevents erosion, and minimizes the chance of subclavian crush syndrome and insulation break. We also selected the minimum possible length of leads. This will possibly decrease the chances of cumbersome fibrosis around the lead and device and will make future implantation convenient. Results There was a total of 602 procedures in the study period. About 253 (42%) procedures were done in the newly adopted strategy and 349 (58%) were performed in the conventional way. Our complication rate grossly reduces in the novel way of implantation in which we took our prick inside the pocket. Conclusion A slight modification in the implantation of CIEDs not only prevents the rate of complication in the index implantation but will also possibly preserve the site for future implantation.
format Online
Article
Text
id pubmed-8933269
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-89332692022-03-28 Strategies for the Long-Term Preservation of Site for Future Implantation of Cardiac Implantable Electronic Devices (CIEDs): Two Decades of Experience Shah, Bakhtawar Saidullah, Shahab Aamer Niaz, Muhammad Zaman, Farrukh Parveen, Zahida Ghazanfar, Aamir Mumtaz, Hassan Cureus Cardiac/Thoracic/Vascular Surgery Introduction Implantation of cardiac implantable electronic devices (CIEDs) is an art of science. As the volume of implantation has increased worldwide, so has the rate of complications. Infection, fibrosis, lead and device erosion, lead displacement, right ventricle perforation, lead fracture, and insulation break are the common complications in the implantation process. This exposes the patient for reopening and threatens the implantation for further complication due to infection, fibrosis of veins, failure to retrieve the implanted wire, and failure to re-implant the device on the same site. We slightly changed our implantation technique to preserve the implantation site for future implantation and reduce the rate of complication in the index implantation. Methods This randomized control trial was conducted from January 2016 to September 2019 at Hayatabad Medical Complex Peshawar, Pakistan. A consecutive sampling technique was used to obtain a sample size of 602 patients keeping a 95% confidence interval and a 5% margin error. We adopted a strategy to take prick, for implantation of devices, inside the pocket, which reduces the number of sutures, hastens the procedure, prevents erosion, and minimizes the chance of subclavian crush syndrome and insulation break. We also selected the minimum possible length of leads. This will possibly decrease the chances of cumbersome fibrosis around the lead and device and will make future implantation convenient. Results There was a total of 602 procedures in the study period. About 253 (42%) procedures were done in the newly adopted strategy and 349 (58%) were performed in the conventional way. Our complication rate grossly reduces in the novel way of implantation in which we took our prick inside the pocket. Conclusion A slight modification in the implantation of CIEDs not only prevents the rate of complication in the index implantation but will also possibly preserve the site for future implantation. Cureus 2022-02-15 /pmc/articles/PMC8933269/ /pubmed/35350505 http://dx.doi.org/10.7759/cureus.22259 Text en Copyright © 2022, Shah et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Cardiac/Thoracic/Vascular Surgery
Shah, Bakhtawar
Saidullah, Shahab
Aamer Niaz, Muhammad
Zaman, Farrukh
Parveen, Zahida
Ghazanfar, Aamir
Mumtaz, Hassan
Strategies for the Long-Term Preservation of Site for Future Implantation of Cardiac Implantable Electronic Devices (CIEDs): Two Decades of Experience
title Strategies for the Long-Term Preservation of Site for Future Implantation of Cardiac Implantable Electronic Devices (CIEDs): Two Decades of Experience
title_full Strategies for the Long-Term Preservation of Site for Future Implantation of Cardiac Implantable Electronic Devices (CIEDs): Two Decades of Experience
title_fullStr Strategies for the Long-Term Preservation of Site for Future Implantation of Cardiac Implantable Electronic Devices (CIEDs): Two Decades of Experience
title_full_unstemmed Strategies for the Long-Term Preservation of Site for Future Implantation of Cardiac Implantable Electronic Devices (CIEDs): Two Decades of Experience
title_short Strategies for the Long-Term Preservation of Site for Future Implantation of Cardiac Implantable Electronic Devices (CIEDs): Two Decades of Experience
title_sort strategies for the long-term preservation of site for future implantation of cardiac implantable electronic devices (cieds): two decades of experience
topic Cardiac/Thoracic/Vascular Surgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8933269/
https://www.ncbi.nlm.nih.gov/pubmed/35350505
http://dx.doi.org/10.7759/cureus.22259
work_keys_str_mv AT shahbakhtawar strategiesforthelongtermpreservationofsiteforfutureimplantationofcardiacimplantableelectronicdevicesciedstwodecadesofexperience
AT saidullahshahab strategiesforthelongtermpreservationofsiteforfutureimplantationofcardiacimplantableelectronicdevicesciedstwodecadesofexperience
AT aamerniazmuhammad strategiesforthelongtermpreservationofsiteforfutureimplantationofcardiacimplantableelectronicdevicesciedstwodecadesofexperience
AT zamanfarrukh strategiesforthelongtermpreservationofsiteforfutureimplantationofcardiacimplantableelectronicdevicesciedstwodecadesofexperience
AT parveenzahida strategiesforthelongtermpreservationofsiteforfutureimplantationofcardiacimplantableelectronicdevicesciedstwodecadesofexperience
AT ghazanfaraamir strategiesforthelongtermpreservationofsiteforfutureimplantationofcardiacimplantableelectronicdevicesciedstwodecadesofexperience
AT mumtazhassan strategiesforthelongtermpreservationofsiteforfutureimplantationofcardiacimplantableelectronicdevicesciedstwodecadesofexperience