Cargando…
Optic nerve sheath diameter in severe preeclampsia with neurologic features versus controls
BACKGROUND: Optic nerve sheath diameters (ONSD) have been validated as an accurate screening tool to detect elevated intracranial pressure in hypertensive encephalopathy. The neurologic manifestations of preeclampsia and/or eclampsia mimic those of hypertensive encephalopathy. This study was perform...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8933926/ https://www.ncbi.nlm.nih.gov/pubmed/35305582 http://dx.doi.org/10.1186/s12884-022-04548-8 |
_version_ | 1784671763149357056 |
---|---|
author | Sterrett, Mary E. Austin, Brittany Barnes, Ryan M. Chang, Eugene Y. |
author_facet | Sterrett, Mary E. Austin, Brittany Barnes, Ryan M. Chang, Eugene Y. |
author_sort | Sterrett, Mary E. |
collection | PubMed |
description | BACKGROUND: Optic nerve sheath diameters (ONSD) have been validated as an accurate screening tool to detect elevated intracranial pressure in hypertensive encephalopathy. The neurologic manifestations of preeclampsia and/or eclampsia mimic those of hypertensive encephalopathy. This study was performed to assess the incidence of elevated optic nerve sheath diameters of patients with severe preeclampsia and neurologic criteria compared to non-preeclamptic patients. The secondary objective was to determine baseline optic nerve sheath diameters in patients with severe preeclampsia without neurologic criteria and preeclampsia without severe features. METHODS: Single site cohort study including 62 pregnant women 18 years or older and 20 weeks or further gestation. Patients with preeclampsia without severe features, preeclampsia with severe features by non-neurologic criteria, preeclampsia with severe features with neurologic criteria, and patients without preeclampsia were enrolled via convenience sampling. One blinded reviewer measured sheath diameters; baseline demographics and pregnancy data were collected by chart review. Statistical analysis was completed with STATA/IC 16. Categorical variables were compared by the χ(2 )test. Continuous variables were presented as mean ± standard deviation, and discrete variables were presented as medians and compared by Kruskal–Wallis testing. Normality was confirmed by Shapiro–Wilk testing. Linear and logistic regression were used to test the association between the preeclampsia groups and optic nerve sheath diameters. Models were presented as unadjusted and adjusted for BMI, gestation, hypertension, diabetes, parity, and gravidity. RESULTS: The incidence of optic nerve sheath diameters > 5.8 mm was 43.8% in the severe preeclampsia with neurologic features cohort, and 42.1% in the control cohort, with a relative risk of 1.04. Patients with severe preeclampsia without neurologic features had sheath diameters of 5.75 mm ± 1.09 mm; non-severe preeclampsia patients had sheath diameters of 5.54 mm ± 1.26 mm. CONCLUSIONS: We did not find a significant elevated optic nerve sheath diameter relative risk between severe preeclampsia patients with neurologic features and non-preeclampsia control patients. This is the first study to assess a North American population utilizing ACOG criteria for severe and non-severe preeclampsia, with severe cohorts additionally stratified by neurologic criteria. |
format | Online Article Text |
id | pubmed-8933926 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-89339262022-03-23 Optic nerve sheath diameter in severe preeclampsia with neurologic features versus controls Sterrett, Mary E. Austin, Brittany Barnes, Ryan M. Chang, Eugene Y. BMC Pregnancy Childbirth Research Article BACKGROUND: Optic nerve sheath diameters (ONSD) have been validated as an accurate screening tool to detect elevated intracranial pressure in hypertensive encephalopathy. The neurologic manifestations of preeclampsia and/or eclampsia mimic those of hypertensive encephalopathy. This study was performed to assess the incidence of elevated optic nerve sheath diameters of patients with severe preeclampsia and neurologic criteria compared to non-preeclamptic patients. The secondary objective was to determine baseline optic nerve sheath diameters in patients with severe preeclampsia without neurologic criteria and preeclampsia without severe features. METHODS: Single site cohort study including 62 pregnant women 18 years or older and 20 weeks or further gestation. Patients with preeclampsia without severe features, preeclampsia with severe features by non-neurologic criteria, preeclampsia with severe features with neurologic criteria, and patients without preeclampsia were enrolled via convenience sampling. One blinded reviewer measured sheath diameters; baseline demographics and pregnancy data were collected by chart review. Statistical analysis was completed with STATA/IC 16. Categorical variables were compared by the χ(2 )test. Continuous variables were presented as mean ± standard deviation, and discrete variables were presented as medians and compared by Kruskal–Wallis testing. Normality was confirmed by Shapiro–Wilk testing. Linear and logistic regression were used to test the association between the preeclampsia groups and optic nerve sheath diameters. Models were presented as unadjusted and adjusted for BMI, gestation, hypertension, diabetes, parity, and gravidity. RESULTS: The incidence of optic nerve sheath diameters > 5.8 mm was 43.8% in the severe preeclampsia with neurologic features cohort, and 42.1% in the control cohort, with a relative risk of 1.04. Patients with severe preeclampsia without neurologic features had sheath diameters of 5.75 mm ± 1.09 mm; non-severe preeclampsia patients had sheath diameters of 5.54 mm ± 1.26 mm. CONCLUSIONS: We did not find a significant elevated optic nerve sheath diameter relative risk between severe preeclampsia patients with neurologic features and non-preeclampsia control patients. This is the first study to assess a North American population utilizing ACOG criteria for severe and non-severe preeclampsia, with severe cohorts additionally stratified by neurologic criteria. BioMed Central 2022-03-19 /pmc/articles/PMC8933926/ /pubmed/35305582 http://dx.doi.org/10.1186/s12884-022-04548-8 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Sterrett, Mary E. Austin, Brittany Barnes, Ryan M. Chang, Eugene Y. Optic nerve sheath diameter in severe preeclampsia with neurologic features versus controls |
title | Optic nerve sheath diameter in severe preeclampsia with neurologic features versus controls |
title_full | Optic nerve sheath diameter in severe preeclampsia with neurologic features versus controls |
title_fullStr | Optic nerve sheath diameter in severe preeclampsia with neurologic features versus controls |
title_full_unstemmed | Optic nerve sheath diameter in severe preeclampsia with neurologic features versus controls |
title_short | Optic nerve sheath diameter in severe preeclampsia with neurologic features versus controls |
title_sort | optic nerve sheath diameter in severe preeclampsia with neurologic features versus controls |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8933926/ https://www.ncbi.nlm.nih.gov/pubmed/35305582 http://dx.doi.org/10.1186/s12884-022-04548-8 |
work_keys_str_mv | AT sterrettmarye opticnervesheathdiameterinseverepreeclampsiawithneurologicfeaturesversuscontrols AT austinbrittany opticnervesheathdiameterinseverepreeclampsiawithneurologicfeaturesversuscontrols AT barnesryanm opticnervesheathdiameterinseverepreeclampsiawithneurologicfeaturesversuscontrols AT changeugeney opticnervesheathdiameterinseverepreeclampsiawithneurologicfeaturesversuscontrols |