Cargando…

Usefulness of silent magnetic resonance angiography (MRA) for the diagnosis of atherosclerosis of the internal carotid artery siphon in comparison with time-of-flight MRA

BACKGROUND AND PURPOSE: Flow visualization in 3D time-of-flight MRA (3D-TOF MRA) may be limited for internal carotid artery siphon owing to turbulent artifact. The purpose of this study was to compare the usefulness of Silent MRA and 3D-TOF MRA to assess atherosclerosis of the internal carotid arter...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Rui, Jin, Song, Wu, Tao, Zang, Xiao, Li, Meng, Li, Jinfeng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8935786/
https://www.ncbi.nlm.nih.gov/pubmed/35314001
http://dx.doi.org/10.1186/s40001-022-00673-4
_version_ 1784672100579016704
author Li, Rui
Jin, Song
Wu, Tao
Zang, Xiao
Li, Meng
Li, Jinfeng
author_facet Li, Rui
Jin, Song
Wu, Tao
Zang, Xiao
Li, Meng
Li, Jinfeng
author_sort Li, Rui
collection PubMed
description BACKGROUND AND PURPOSE: Flow visualization in 3D time-of-flight MRA (3D-TOF MRA) may be limited for internal carotid artery siphon owing to turbulent artifact. The purpose of this study was to compare the usefulness of Silent MRA and 3D-TOF MRA to assess atherosclerosis of the internal carotid artery siphon. MATERIAL AND METHODS: A total of 106 patients with suspected cerebrovascular disease were included. All patients were scanned with Silent MRA and 3D-TOF MRA sequences and also underwent DSA examination. Two observers independently assessed the TOF MRA and Silent MRA images of atherosclerosis of the internal carotid artery siphon. The diagnostic efficacy of two MRA methods in evaluating atherosclerosis of the carotid siphon was performed by using receiver operating characteristic (ROC) curve analysis. Interobserver reliability was also assessed using weighted kappa statistics. RESULTS: Image of Silent MRA sequence had higher subjective evaluation scores and significantly high CNR between the carotid siphon and the background tissues than the image of 3D-TOF MRA sequence (P < 0.05). The AUC was 0.928 (95% CI 0.909–0.986) for Silent MRA, which was significantly higher than that of 3D-TOF MRA (0.671, 95% CI 0.610–0.801, P < 0.05). Silent MRA had high sensitivity, specificity and accuracy than 3D-TOF MRA for visualization of the carotid siphon. CONCLUSIONS: Silent MRA as a new angiographic modality is superior to 3D-TOF MRA for visualization of the carotid siphon, and maybe an alternative to 3D-TOF MRA in the diagnosis of atherosclerosis of the carotid siphon.
format Online
Article
Text
id pubmed-8935786
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-89357862022-03-23 Usefulness of silent magnetic resonance angiography (MRA) for the diagnosis of atherosclerosis of the internal carotid artery siphon in comparison with time-of-flight MRA Li, Rui Jin, Song Wu, Tao Zang, Xiao Li, Meng Li, Jinfeng Eur J Med Res Research BACKGROUND AND PURPOSE: Flow visualization in 3D time-of-flight MRA (3D-TOF MRA) may be limited for internal carotid artery siphon owing to turbulent artifact. The purpose of this study was to compare the usefulness of Silent MRA and 3D-TOF MRA to assess atherosclerosis of the internal carotid artery siphon. MATERIAL AND METHODS: A total of 106 patients with suspected cerebrovascular disease were included. All patients were scanned with Silent MRA and 3D-TOF MRA sequences and also underwent DSA examination. Two observers independently assessed the TOF MRA and Silent MRA images of atherosclerosis of the internal carotid artery siphon. The diagnostic efficacy of two MRA methods in evaluating atherosclerosis of the carotid siphon was performed by using receiver operating characteristic (ROC) curve analysis. Interobserver reliability was also assessed using weighted kappa statistics. RESULTS: Image of Silent MRA sequence had higher subjective evaluation scores and significantly high CNR between the carotid siphon and the background tissues than the image of 3D-TOF MRA sequence (P < 0.05). The AUC was 0.928 (95% CI 0.909–0.986) for Silent MRA, which was significantly higher than that of 3D-TOF MRA (0.671, 95% CI 0.610–0.801, P < 0.05). Silent MRA had high sensitivity, specificity and accuracy than 3D-TOF MRA for visualization of the carotid siphon. CONCLUSIONS: Silent MRA as a new angiographic modality is superior to 3D-TOF MRA for visualization of the carotid siphon, and maybe an alternative to 3D-TOF MRA in the diagnosis of atherosclerosis of the carotid siphon. BioMed Central 2022-03-21 /pmc/articles/PMC8935786/ /pubmed/35314001 http://dx.doi.org/10.1186/s40001-022-00673-4 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Li, Rui
Jin, Song
Wu, Tao
Zang, Xiao
Li, Meng
Li, Jinfeng
Usefulness of silent magnetic resonance angiography (MRA) for the diagnosis of atherosclerosis of the internal carotid artery siphon in comparison with time-of-flight MRA
title Usefulness of silent magnetic resonance angiography (MRA) for the diagnosis of atherosclerosis of the internal carotid artery siphon in comparison with time-of-flight MRA
title_full Usefulness of silent magnetic resonance angiography (MRA) for the diagnosis of atherosclerosis of the internal carotid artery siphon in comparison with time-of-flight MRA
title_fullStr Usefulness of silent magnetic resonance angiography (MRA) for the diagnosis of atherosclerosis of the internal carotid artery siphon in comparison with time-of-flight MRA
title_full_unstemmed Usefulness of silent magnetic resonance angiography (MRA) for the diagnosis of atherosclerosis of the internal carotid artery siphon in comparison with time-of-flight MRA
title_short Usefulness of silent magnetic resonance angiography (MRA) for the diagnosis of atherosclerosis of the internal carotid artery siphon in comparison with time-of-flight MRA
title_sort usefulness of silent magnetic resonance angiography (mra) for the diagnosis of atherosclerosis of the internal carotid artery siphon in comparison with time-of-flight mra
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8935786/
https://www.ncbi.nlm.nih.gov/pubmed/35314001
http://dx.doi.org/10.1186/s40001-022-00673-4
work_keys_str_mv AT lirui usefulnessofsilentmagneticresonanceangiographymraforthediagnosisofatherosclerosisoftheinternalcarotidarterysiphonincomparisonwithtimeofflightmra
AT jinsong usefulnessofsilentmagneticresonanceangiographymraforthediagnosisofatherosclerosisoftheinternalcarotidarterysiphonincomparisonwithtimeofflightmra
AT wutao usefulnessofsilentmagneticresonanceangiographymraforthediagnosisofatherosclerosisoftheinternalcarotidarterysiphonincomparisonwithtimeofflightmra
AT zangxiao usefulnessofsilentmagneticresonanceangiographymraforthediagnosisofatherosclerosisoftheinternalcarotidarterysiphonincomparisonwithtimeofflightmra
AT limeng usefulnessofsilentmagneticresonanceangiographymraforthediagnosisofatherosclerosisoftheinternalcarotidarterysiphonincomparisonwithtimeofflightmra
AT lijinfeng usefulnessofsilentmagneticresonanceangiographymraforthediagnosisofatherosclerosisoftheinternalcarotidarterysiphonincomparisonwithtimeofflightmra