Cargando…

Accuracy of Stereovision-Updated Versus Preoperative CT-Based Image Guidance in Multilevel Lumbar Pedicle Screw Placement: A Cadaveric Swine Study

BACKGROUND: Change in vertebral position between preoperative imaging and the surgical procedure reduces the accuracy of image-guided spinal surgery, requiring repeated imaging and surgical field registration, a process that takes time and exposes patients to additional radiation. We developed a han...

Descripción completa

Detalles Bibliográficos
Autores principales: Fan, Xiaoyao, Mirza, Sohail K., Li, Chen, Evans, Linton T., Ji, Songbai, Paulsen, Keith D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Journal of Bone and Joint Surgery, Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8937011/
https://www.ncbi.nlm.nih.gov/pubmed/35350121
http://dx.doi.org/10.2106/JBJS.OA.21.00129
_version_ 1784672266556014592
author Fan, Xiaoyao
Mirza, Sohail K.
Li, Chen
Evans, Linton T.
Ji, Songbai
Paulsen, Keith D.
author_facet Fan, Xiaoyao
Mirza, Sohail K.
Li, Chen
Evans, Linton T.
Ji, Songbai
Paulsen, Keith D.
author_sort Fan, Xiaoyao
collection PubMed
description BACKGROUND: Change in vertebral position between preoperative imaging and the surgical procedure reduces the accuracy of image-guided spinal surgery, requiring repeated imaging and surgical field registration, a process that takes time and exposes patients to additional radiation. We developed a handheld, camera-based, deformable registration system (intraoperative stereovision, iSV) to register the surgical field automatically and compensate for spinal motion during surgery without further radiation exposure. METHODS: We measured motion-induced errors in image-guided lumbar pedicle screw placement in 6 whole-pig cadavers using state-of-the-art commercial spine navigation (StealthStation; Medtronic) and iSV registration that compensates for intraoperative vertebral motion. We induced spinal motion by using preoperative computed tomography (pCT) of the lumbar spine performed in the supine position with accentuated lordosis and performing surgery with the animal in the prone position. StealthStation registration of pCT occurred using metallic fiducial markers implanted in each vertebra, and iSV data were acquired to perform a deformable registration between pCT and the surgical field. Sixty-eight pedicle screws were placed in 6 whole-pig cadavers using iSV and StealthStation registrations in random order of vertebral level, relying only on image guidance without invoking the surgeon’s judgment. The position of each pedicle screw was assessed with post-procedure CT and confirmed via anatomical dissection. Registration errors were assessed on the basis of implanted fiducials. RESULTS: The frequency and severity of pedicle screw perforation were lower for iSV registration compared with StealthStation (97% versus 68% with Grade 0 medial perforation for iSV and StealthStation, respectively). Severe perforation occurred only with StealthStation (18% versus 0% for iSV). The overall time required for iSV registration (computational efficiency) was ∼10 to 15 minutes and was comparable with StealthStation registration (∼10 min). The mean target registration error was smaller for iSV relative to StealthStation (2.81 ± 0.91 versus 8.37 ± 1.76 mm). CONCLUSIONS: Pedicle screw placement was more accurate with iSV registration compared with state-of-the-art commercial navigation based on preoperative CT when alignment of the spine changed during surgery. CLINICAL RELEVANCE: The iSV system compensated for intervertebral motion, which obviated the need for repeated vertebral registration while providing efficient, accurate, radiation-free navigation during open spinal surgery.
format Online
Article
Text
id pubmed-8937011
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Journal of Bone and Joint Surgery, Inc.
record_format MEDLINE/PubMed
spelling pubmed-89370112022-03-28 Accuracy of Stereovision-Updated Versus Preoperative CT-Based Image Guidance in Multilevel Lumbar Pedicle Screw Placement: A Cadaveric Swine Study Fan, Xiaoyao Mirza, Sohail K. Li, Chen Evans, Linton T. Ji, Songbai Paulsen, Keith D. JB JS Open Access Scientific Articles BACKGROUND: Change in vertebral position between preoperative imaging and the surgical procedure reduces the accuracy of image-guided spinal surgery, requiring repeated imaging and surgical field registration, a process that takes time and exposes patients to additional radiation. We developed a handheld, camera-based, deformable registration system (intraoperative stereovision, iSV) to register the surgical field automatically and compensate for spinal motion during surgery without further radiation exposure. METHODS: We measured motion-induced errors in image-guided lumbar pedicle screw placement in 6 whole-pig cadavers using state-of-the-art commercial spine navigation (StealthStation; Medtronic) and iSV registration that compensates for intraoperative vertebral motion. We induced spinal motion by using preoperative computed tomography (pCT) of the lumbar spine performed in the supine position with accentuated lordosis and performing surgery with the animal in the prone position. StealthStation registration of pCT occurred using metallic fiducial markers implanted in each vertebra, and iSV data were acquired to perform a deformable registration between pCT and the surgical field. Sixty-eight pedicle screws were placed in 6 whole-pig cadavers using iSV and StealthStation registrations in random order of vertebral level, relying only on image guidance without invoking the surgeon’s judgment. The position of each pedicle screw was assessed with post-procedure CT and confirmed via anatomical dissection. Registration errors were assessed on the basis of implanted fiducials. RESULTS: The frequency and severity of pedicle screw perforation were lower for iSV registration compared with StealthStation (97% versus 68% with Grade 0 medial perforation for iSV and StealthStation, respectively). Severe perforation occurred only with StealthStation (18% versus 0% for iSV). The overall time required for iSV registration (computational efficiency) was ∼10 to 15 minutes and was comparable with StealthStation registration (∼10 min). The mean target registration error was smaller for iSV relative to StealthStation (2.81 ± 0.91 versus 8.37 ± 1.76 mm). CONCLUSIONS: Pedicle screw placement was more accurate with iSV registration compared with state-of-the-art commercial navigation based on preoperative CT when alignment of the spine changed during surgery. CLINICAL RELEVANCE: The iSV system compensated for intervertebral motion, which obviated the need for repeated vertebral registration while providing efficient, accurate, radiation-free navigation during open spinal surgery. Journal of Bone and Joint Surgery, Inc. 2022-03-21 /pmc/articles/PMC8937011/ /pubmed/35350121 http://dx.doi.org/10.2106/JBJS.OA.21.00129 Text en Copyright © 2022 The Authors. Published by The Journal of Bone and Joint Surgery, Incorporated. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
spellingShingle Scientific Articles
Fan, Xiaoyao
Mirza, Sohail K.
Li, Chen
Evans, Linton T.
Ji, Songbai
Paulsen, Keith D.
Accuracy of Stereovision-Updated Versus Preoperative CT-Based Image Guidance in Multilevel Lumbar Pedicle Screw Placement: A Cadaveric Swine Study
title Accuracy of Stereovision-Updated Versus Preoperative CT-Based Image Guidance in Multilevel Lumbar Pedicle Screw Placement: A Cadaveric Swine Study
title_full Accuracy of Stereovision-Updated Versus Preoperative CT-Based Image Guidance in Multilevel Lumbar Pedicle Screw Placement: A Cadaveric Swine Study
title_fullStr Accuracy of Stereovision-Updated Versus Preoperative CT-Based Image Guidance in Multilevel Lumbar Pedicle Screw Placement: A Cadaveric Swine Study
title_full_unstemmed Accuracy of Stereovision-Updated Versus Preoperative CT-Based Image Guidance in Multilevel Lumbar Pedicle Screw Placement: A Cadaveric Swine Study
title_short Accuracy of Stereovision-Updated Versus Preoperative CT-Based Image Guidance in Multilevel Lumbar Pedicle Screw Placement: A Cadaveric Swine Study
title_sort accuracy of stereovision-updated versus preoperative ct-based image guidance in multilevel lumbar pedicle screw placement: a cadaveric swine study
topic Scientific Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8937011/
https://www.ncbi.nlm.nih.gov/pubmed/35350121
http://dx.doi.org/10.2106/JBJS.OA.21.00129
work_keys_str_mv AT fanxiaoyao accuracyofstereovisionupdatedversuspreoperativectbasedimageguidanceinmultilevellumbarpediclescrewplacementacadavericswinestudy
AT mirzasohailk accuracyofstereovisionupdatedversuspreoperativectbasedimageguidanceinmultilevellumbarpediclescrewplacementacadavericswinestudy
AT lichen accuracyofstereovisionupdatedversuspreoperativectbasedimageguidanceinmultilevellumbarpediclescrewplacementacadavericswinestudy
AT evanslintont accuracyofstereovisionupdatedversuspreoperativectbasedimageguidanceinmultilevellumbarpediclescrewplacementacadavericswinestudy
AT jisongbai accuracyofstereovisionupdatedversuspreoperativectbasedimageguidanceinmultilevellumbarpediclescrewplacementacadavericswinestudy
AT paulsenkeithd accuracyofstereovisionupdatedversuspreoperativectbasedimageguidanceinmultilevellumbarpediclescrewplacementacadavericswinestudy