Cargando…
Nanocarbon Tracer and Areola Injection Site Are Superior in the Sentinel Lymph Node Biopsy Procedure for Breast Cancer
BACKGROUND: Axillary lymph node (ALN) staging is the most effective method to evaluate the condition of patients with breast cancer, their choice of treatment options, and prognosis. The sentinel lymph node (SLN) status assessment is the key to sentinel lymph node biopsy (SLNB) in patients with brea...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8938060/ https://www.ncbi.nlm.nih.gov/pubmed/35321201 http://dx.doi.org/10.1155/2022/4066179 |
_version_ | 1784672470993731584 |
---|---|
author | Song, Bo Zhang, Binming An, Aihu Bai, Yue Gao, Bo |
author_facet | Song, Bo Zhang, Binming An, Aihu Bai, Yue Gao, Bo |
author_sort | Song, Bo |
collection | PubMed |
description | BACKGROUND: Axillary lymph node (ALN) staging is the most effective method to evaluate the condition of patients with breast cancer, their choice of treatment options, and prognosis. The sentinel lymph node (SLN) status assessment is the key to sentinel lymph node biopsy (SLNB) in patients with breast cancer. The choice of tracer and tracer injection sites affects SLNB. OBJECTIVE: This study mainly analyzes the best tracer for SLNB and the best choice of tracer injection site. METHODS: A total of 165 breast cancer patients who underwent SLNB were selected and injected with methylene blue or 99mTc-labeled sodium phytate or nanocarbon 20 min before biopsy. The number of SLNs detected by different tracers in different injection sites such as peritumoral tissue (PT) and subareolar area (SA) was counted, and the sensitivity, specificity, and positive/negative prediction rates were recorded and compared. RESULTS: The detection success rate, average detection number of SLNs, and detection accuracy of the nanocarbon tracer were higher than the other two. The detection sensitivity, specificity, and positive and negative prediction rates of nanocarbon for SLNB were also higher than those of the other two tracers. When comparing the performance of tracers in different injection sites, it was found that the detection of three tracers injected in the SA was better than the injection in the PT. CONCLUSION: For women with early-stage breast cancer, nanocarbon can be used as the preferred tracer for SLNB to determine the status of the patient's ALNs, and the areola area can be used as the best injection site. |
format | Online Article Text |
id | pubmed-8938060 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-89380602022-03-22 Nanocarbon Tracer and Areola Injection Site Are Superior in the Sentinel Lymph Node Biopsy Procedure for Breast Cancer Song, Bo Zhang, Binming An, Aihu Bai, Yue Gao, Bo Comput Math Methods Med Research Article BACKGROUND: Axillary lymph node (ALN) staging is the most effective method to evaluate the condition of patients with breast cancer, their choice of treatment options, and prognosis. The sentinel lymph node (SLN) status assessment is the key to sentinel lymph node biopsy (SLNB) in patients with breast cancer. The choice of tracer and tracer injection sites affects SLNB. OBJECTIVE: This study mainly analyzes the best tracer for SLNB and the best choice of tracer injection site. METHODS: A total of 165 breast cancer patients who underwent SLNB were selected and injected with methylene blue or 99mTc-labeled sodium phytate or nanocarbon 20 min before biopsy. The number of SLNs detected by different tracers in different injection sites such as peritumoral tissue (PT) and subareolar area (SA) was counted, and the sensitivity, specificity, and positive/negative prediction rates were recorded and compared. RESULTS: The detection success rate, average detection number of SLNs, and detection accuracy of the nanocarbon tracer were higher than the other two. The detection sensitivity, specificity, and positive and negative prediction rates of nanocarbon for SLNB were also higher than those of the other two tracers. When comparing the performance of tracers in different injection sites, it was found that the detection of three tracers injected in the SA was better than the injection in the PT. CONCLUSION: For women with early-stage breast cancer, nanocarbon can be used as the preferred tracer for SLNB to determine the status of the patient's ALNs, and the areola area can be used as the best injection site. Hindawi 2022-03-14 /pmc/articles/PMC8938060/ /pubmed/35321201 http://dx.doi.org/10.1155/2022/4066179 Text en Copyright © 2022 Bo Song et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Song, Bo Zhang, Binming An, Aihu Bai, Yue Gao, Bo Nanocarbon Tracer and Areola Injection Site Are Superior in the Sentinel Lymph Node Biopsy Procedure for Breast Cancer |
title | Nanocarbon Tracer and Areola Injection Site Are Superior in the Sentinel Lymph Node Biopsy Procedure for Breast Cancer |
title_full | Nanocarbon Tracer and Areola Injection Site Are Superior in the Sentinel Lymph Node Biopsy Procedure for Breast Cancer |
title_fullStr | Nanocarbon Tracer and Areola Injection Site Are Superior in the Sentinel Lymph Node Biopsy Procedure for Breast Cancer |
title_full_unstemmed | Nanocarbon Tracer and Areola Injection Site Are Superior in the Sentinel Lymph Node Biopsy Procedure for Breast Cancer |
title_short | Nanocarbon Tracer and Areola Injection Site Are Superior in the Sentinel Lymph Node Biopsy Procedure for Breast Cancer |
title_sort | nanocarbon tracer and areola injection site are superior in the sentinel lymph node biopsy procedure for breast cancer |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8938060/ https://www.ncbi.nlm.nih.gov/pubmed/35321201 http://dx.doi.org/10.1155/2022/4066179 |
work_keys_str_mv | AT songbo nanocarbontracerandareolainjectionsitearesuperiorinthesentinellymphnodebiopsyprocedureforbreastcancer AT zhangbinming nanocarbontracerandareolainjectionsitearesuperiorinthesentinellymphnodebiopsyprocedureforbreastcancer AT anaihu nanocarbontracerandareolainjectionsitearesuperiorinthesentinellymphnodebiopsyprocedureforbreastcancer AT baiyue nanocarbontracerandareolainjectionsitearesuperiorinthesentinellymphnodebiopsyprocedureforbreastcancer AT gaobo nanocarbontracerandareolainjectionsitearesuperiorinthesentinellymphnodebiopsyprocedureforbreastcancer |