Cargando…

Strategy to Reduce Hypercapnia in Robot-Assisted Radical Prostatectomy Using Transcutaneous Carbon Dioxide Monitoring: A Prospective Observational Study

PURPOSE: Monitoring end-tidal carbon dioxide partial pressure (P(ET)CO(2)) is a noninvasive, continuous method, but its accuracy is reduced by prolonged capnoperitoneum and the steep Trendelenburg position in robot-assisted radical prostatectomy (RARP). Transcutaneous carbon dioxide partial pressure...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Hyun Jung, Chae, Ji Seon, An, Sang-Mee, Oh, Hye-Won, Kim, Youn Jin, Woo, Jae Hee
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8938168/
https://www.ncbi.nlm.nih.gov/pubmed/35330918
http://dx.doi.org/10.2147/TCRM.S347690
Descripción
Sumario:PURPOSE: Monitoring end-tidal carbon dioxide partial pressure (P(ET)CO(2)) is a noninvasive, continuous method, but its accuracy is reduced by prolonged capnoperitoneum and the steep Trendelenburg position in robot-assisted radical prostatectomy (RARP). Transcutaneous carbon dioxide partial pressure (P(TC)CO(2)) monitoring, which is not affected by ventilator–perfusion mismatch, has been suggested as a suitable alternative. We compared the agreement of noninvasive measurements with the arterial carbon dioxide partial pressure (PaCO(2)) over a long period of capnoperitoneum, and investigated its sensitivity and predictive power for detecting hypercapnia. PATIENTS AND METHODS: The patients who underwent RARP were enrolled in this study prospectively. Intraoperative measurements of P(ET)CO(2), P(TC)CO(2), and PaCO(2) were analyzed. The primary outcome was the agreement of noninvasive monitoring with PaCO(2) during prolonged capnoperitoneum. Bias and precision between noninvasive measurements and PaCO(2) were assessed using Bland–Altman analysis. The bias and mean absolute difference were compared using a two-tailed Wilcoxon signed-rank test for pairs. The secondary outcome was the sensitivity and predictive power for detecting hypercapnia. To assess this, the Yates corrected chi-square test and the area under the receiver operating characteristic curve were used. RESULTS: The study analyzed 219 datasets from 46 patients. Compared with P(ET)CO(2), P(TC)CO(2) had lower bias, greater precision, and better agreement with PaCO(2) throughout the RARP. The mean absolute difference in P(ET)CO(2) and PaCO(2) was larger than that of P(TC)CO(2) and PaCO(2,) and continued to exceed the clinically acceptable range of 5 mmHg after 1 hour of capnoperitoneum. The sensitivity during capnoperitoneum and overall predictive power of P(TC)CO(2) for detecting hypercapnia were significantly higher than those of P(ET)CO(2), suggesting a greater contribution to ventilator adjustment, to treat hypercapnia. CONCLUSION: P(TC)CO(2) monitoring measured PaCO(2) more accurately than P(ET)CO(2) monitoring during RARP requiring prolonged capnoperitoneum and a steep Trendelenburg position. P(TC)CO(2) monitoring also provides more sensitive measurements for ventilator adjustment and detects hypercapnia more effectively than P(ET)CO(2) monitoring.