Cargando…

Using solid-phase microextraction during ultrasound reveals higher aqueous PAHs release from contaminated sediment

Ultrasound (US) releases polycyclic aromatic hydrocarbons (PAHs) from contaminated creosote sediments and degrades PAHs in aqueous solution. However, it is unclear how much PAHs release occurs during active US compared to after US is stopped. In this study, solid-phase microextraction (SPME) was use...

Descripción completa

Detalles Bibliográficos
Autores principales: Kohan, Danielle S., Lanno, Roman P., Weavers, Linda K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8938626/
https://www.ncbi.nlm.nih.gov/pubmed/35320772
http://dx.doi.org/10.1016/j.ultsonch.2022.105981
_version_ 1784672586318217216
author Kohan, Danielle S.
Lanno, Roman P.
Weavers, Linda K.
author_facet Kohan, Danielle S.
Lanno, Roman P.
Weavers, Linda K.
author_sort Kohan, Danielle S.
collection PubMed
description Ultrasound (US) releases polycyclic aromatic hydrocarbons (PAHs) from contaminated creosote sediments and degrades PAHs in aqueous solution. However, it is unclear how much PAHs release occurs during active US compared to after US is stopped. In this study, solid-phase microextraction (SPME) was used to determine aqueous PAH concentrations desorbed from Little Scioto River creosote contaminated sediment during exposure to 20 kHz ultrasound (US) at a power of 430 W L(−1). First, SPME fiber-water partition coefficients, [Formula: see text] , were experimentally determined and shown to be comparable with previous studies. Next, PAH concentrations released into aqueous solution were determined by sequentially exposing fresh, conditioned SPME fibers in a reactor containing the contaminated sediment and DI for 10 min periods. Three consecutive 10 min periods each were measured during US and after US. Compared to mixing only, PAHs desorbed during ultrasound was significantly higher. In addition, for phenanthrene, anthracene, and fluoranthene, US showed significantly higher aqueous concentrations during US compared with after US. For these less soluble PAHs, desorption into the aqueous phase reaches and surpasses expected equilibrium aqueous concentrations. However, when US is ceased, PAHs appear to resorb onto sediment resulting in the lower concentrations measured in these PAH compounds after US that are similar to expected equilibrium aqueous concentrations. Typical analytical extraction methods for determining the effects of US require stopping treatment and may underestimate the potential US has for release of contaminants from sediment during US. Using SPME during US treatment reveals that the concentration of PAHs during US may surpass the expected equilibrium aqueous concentration of some PAHs congeners. To our knowledge, this higher concentration observed during US compared to after US has not been shown previously.
format Online
Article
Text
id pubmed-8938626
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-89386262022-03-23 Using solid-phase microextraction during ultrasound reveals higher aqueous PAHs release from contaminated sediment Kohan, Danielle S. Lanno, Roman P. Weavers, Linda K. Ultrason Sonochem Short Communication Ultrasound (US) releases polycyclic aromatic hydrocarbons (PAHs) from contaminated creosote sediments and degrades PAHs in aqueous solution. However, it is unclear how much PAHs release occurs during active US compared to after US is stopped. In this study, solid-phase microextraction (SPME) was used to determine aqueous PAH concentrations desorbed from Little Scioto River creosote contaminated sediment during exposure to 20 kHz ultrasound (US) at a power of 430 W L(−1). First, SPME fiber-water partition coefficients, [Formula: see text] , were experimentally determined and shown to be comparable with previous studies. Next, PAH concentrations released into aqueous solution were determined by sequentially exposing fresh, conditioned SPME fibers in a reactor containing the contaminated sediment and DI for 10 min periods. Three consecutive 10 min periods each were measured during US and after US. Compared to mixing only, PAHs desorbed during ultrasound was significantly higher. In addition, for phenanthrene, anthracene, and fluoranthene, US showed significantly higher aqueous concentrations during US compared with after US. For these less soluble PAHs, desorption into the aqueous phase reaches and surpasses expected equilibrium aqueous concentrations. However, when US is ceased, PAHs appear to resorb onto sediment resulting in the lower concentrations measured in these PAH compounds after US that are similar to expected equilibrium aqueous concentrations. Typical analytical extraction methods for determining the effects of US require stopping treatment and may underestimate the potential US has for release of contaminants from sediment during US. Using SPME during US treatment reveals that the concentration of PAHs during US may surpass the expected equilibrium aqueous concentration of some PAHs congeners. To our knowledge, this higher concentration observed during US compared to after US has not been shown previously. Elsevier 2022-03-12 /pmc/articles/PMC8938626/ /pubmed/35320772 http://dx.doi.org/10.1016/j.ultsonch.2022.105981 Text en © 2022 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Short Communication
Kohan, Danielle S.
Lanno, Roman P.
Weavers, Linda K.
Using solid-phase microextraction during ultrasound reveals higher aqueous PAHs release from contaminated sediment
title Using solid-phase microextraction during ultrasound reveals higher aqueous PAHs release from contaminated sediment
title_full Using solid-phase microextraction during ultrasound reveals higher aqueous PAHs release from contaminated sediment
title_fullStr Using solid-phase microextraction during ultrasound reveals higher aqueous PAHs release from contaminated sediment
title_full_unstemmed Using solid-phase microextraction during ultrasound reveals higher aqueous PAHs release from contaminated sediment
title_short Using solid-phase microextraction during ultrasound reveals higher aqueous PAHs release from contaminated sediment
title_sort using solid-phase microextraction during ultrasound reveals higher aqueous pahs release from contaminated sediment
topic Short Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8938626/
https://www.ncbi.nlm.nih.gov/pubmed/35320772
http://dx.doi.org/10.1016/j.ultsonch.2022.105981
work_keys_str_mv AT kohandanielles usingsolidphasemicroextractionduringultrasoundrevealshigheraqueouspahsreleasefromcontaminatedsediment
AT lannoromanp usingsolidphasemicroextractionduringultrasoundrevealshigheraqueouspahsreleasefromcontaminatedsediment
AT weaverslindak usingsolidphasemicroextractionduringultrasoundrevealshigheraqueouspahsreleasefromcontaminatedsediment