Field validation of the performance of paper-based tests for the detection of the Zika and chikungunya viruses in serum samples

In low-resource settings, resilience to infectious disease outbreaks can be hindered by limited access to diagnostic tests. Here we report the results of double-blinded studies of the performance of paper-based diagnostic tests for the Zika and chikungunya viruses in a field setting in Latin America...

Descripción completa

Detalles Bibliográficos
Autores principales: Karlikow, Margot, da Silva, Severino Jefferson Ribeiro, Guo, Yuxiu, Cicek, Seray, Krokovsky, Larissa, Homme, Paige, Xiong, Yilin, Xu, Talia, Calderón-Peláez, Maria-Angelica, Camacho-Ortega, Sigrid, Ma, Duo, de Magalhães, Jurandy Júnior Ferraz, Souza, Bárbara Nayane Rosário Fernandes, de Albuquerque Cabral, Diego Guerra, Jaenes, Katariina, Sutyrina, Polina, Ferrante, Tom, Benitez, Andrea Denisse, Nipaz, Victoria, Ponce, Patricio, Rackus, Darius G., Collins, James J., Paiva, Marcelo, Castellanos, Jaime E., Cevallos, Varsovia, Green, Alexander A., Ayres, Constância, Pena, Lindomar, Pardee, Keith
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8940623/
https://www.ncbi.nlm.nih.gov/pubmed/35256758
http://dx.doi.org/10.1038/s41551-022-00850-0
Descripción
Sumario:In low-resource settings, resilience to infectious disease outbreaks can be hindered by limited access to diagnostic tests. Here we report the results of double-blinded studies of the performance of paper-based diagnostic tests for the Zika and chikungunya viruses in a field setting in Latin America. The tests involved a cell-free expression system relying on isothermal amplification and toehold-switch reactions, a purpose-built portable reader and onboard software for computer vision-enabled image analysis. In patients suspected of infection, the accuracies and sensitivities of the tests for the Zika and chikungunya viruses were, respectively, 98.5% (95% confidence interval, 96.2–99.6%, 268 serum samples) and 98.5% (95% confidence interval, 91.7–100%, 65 serum samples) and approximately 2 aM and 5 fM (both concentrations are within clinically relevant ranges). The analytical specificities and sensitivities of the tests for cultured samples of the viruses were equivalent to those of the real-time quantitative PCR. Cell-free synthetic biology tools and companion hardware can provide de-centralized, high-capacity and low-cost diagnostics for use in low-resource settings.