Cargando…
Closed-loop optimization of transcranial magnetic stimulation with electroencephalography feedback
BACKGROUND: Transcranial magnetic stimulation (TMS) is widely used in brain research and treatment of various brain dysfunctions. However, the optimal way to target stimulation and administer TMS therapies, for example, where and in which electric field direction the stimuli should be given, is yet...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8940636/ https://www.ncbi.nlm.nih.gov/pubmed/35337598 http://dx.doi.org/10.1016/j.brs.2022.01.016 |
_version_ | 1784672964004806656 |
---|---|
author | Tervo, Aino E. Nieminen, Jaakko O. Lioumis, Pantelis Metsomaa, Johanna Souza, Victor H. Sinisalo, Heikki Stenroos, Matti Sarvas, Jukka Ilmoniemi, Risto J. |
author_facet | Tervo, Aino E. Nieminen, Jaakko O. Lioumis, Pantelis Metsomaa, Johanna Souza, Victor H. Sinisalo, Heikki Stenroos, Matti Sarvas, Jukka Ilmoniemi, Risto J. |
author_sort | Tervo, Aino E. |
collection | PubMed |
description | BACKGROUND: Transcranial magnetic stimulation (TMS) is widely used in brain research and treatment of various brain dysfunctions. However, the optimal way to target stimulation and administer TMS therapies, for example, where and in which electric field direction the stimuli should be given, is yet to be determined. OBJECTIVE: To develop an automated closed-loop system for adjusting TMS parameters (in this work, the stimulus orientation) online based on TMS-evoked brain activity measured with electroencephalography (EEG). METHODS: We developed an automated closed-loop TMS–EEG set-up. In this set-up, the stimulus parameters are electronically adjusted with multi-locus TMS. As a proof of concept, we developed an algorithm that automatically optimizes the stimulation orientation based on single-trial EEG responses. We applied the algorithm to determine the electric field orientation that maximizes the amplitude of the TMS–EEG responses. The validation of the algorithm was performed with six healthy volunteers, repeating the search twenty times for each subject. RESULTS: The validation demonstrated that the closed-loop control worked as desired despite the large variation in the single-trial EEG responses. We were often able to get close to the orientation that maximizes the EEG amplitude with only a few tens of pulses. CONCLUSION: Optimizing stimulation with EEG feedback in a closed-loop manner is feasible and enables effective coupling to brain activity. |
format | Online Article Text |
id | pubmed-8940636 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-89406362022-03-31 Closed-loop optimization of transcranial magnetic stimulation with electroencephalography feedback Tervo, Aino E. Nieminen, Jaakko O. Lioumis, Pantelis Metsomaa, Johanna Souza, Victor H. Sinisalo, Heikki Stenroos, Matti Sarvas, Jukka Ilmoniemi, Risto J. Brain Stimul Article BACKGROUND: Transcranial magnetic stimulation (TMS) is widely used in brain research and treatment of various brain dysfunctions. However, the optimal way to target stimulation and administer TMS therapies, for example, where and in which electric field direction the stimuli should be given, is yet to be determined. OBJECTIVE: To develop an automated closed-loop system for adjusting TMS parameters (in this work, the stimulus orientation) online based on TMS-evoked brain activity measured with electroencephalography (EEG). METHODS: We developed an automated closed-loop TMS–EEG set-up. In this set-up, the stimulus parameters are electronically adjusted with multi-locus TMS. As a proof of concept, we developed an algorithm that automatically optimizes the stimulation orientation based on single-trial EEG responses. We applied the algorithm to determine the electric field orientation that maximizes the amplitude of the TMS–EEG responses. The validation of the algorithm was performed with six healthy volunteers, repeating the search twenty times for each subject. RESULTS: The validation demonstrated that the closed-loop control worked as desired despite the large variation in the single-trial EEG responses. We were often able to get close to the orientation that maximizes the EEG amplitude with only a few tens of pulses. CONCLUSION: Optimizing stimulation with EEG feedback in a closed-loop manner is feasible and enables effective coupling to brain activity. Elsevier 2022 /pmc/articles/PMC8940636/ /pubmed/35337598 http://dx.doi.org/10.1016/j.brs.2022.01.016 Text en © 2022 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Article Tervo, Aino E. Nieminen, Jaakko O. Lioumis, Pantelis Metsomaa, Johanna Souza, Victor H. Sinisalo, Heikki Stenroos, Matti Sarvas, Jukka Ilmoniemi, Risto J. Closed-loop optimization of transcranial magnetic stimulation with electroencephalography feedback |
title | Closed-loop optimization of transcranial magnetic stimulation with electroencephalography feedback |
title_full | Closed-loop optimization of transcranial magnetic stimulation with electroencephalography feedback |
title_fullStr | Closed-loop optimization of transcranial magnetic stimulation with electroencephalography feedback |
title_full_unstemmed | Closed-loop optimization of transcranial magnetic stimulation with electroencephalography feedback |
title_short | Closed-loop optimization of transcranial magnetic stimulation with electroencephalography feedback |
title_sort | closed-loop optimization of transcranial magnetic stimulation with electroencephalography feedback |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8940636/ https://www.ncbi.nlm.nih.gov/pubmed/35337598 http://dx.doi.org/10.1016/j.brs.2022.01.016 |
work_keys_str_mv | AT tervoainoe closedloopoptimizationoftranscranialmagneticstimulationwithelectroencephalographyfeedback AT nieminenjaakkoo closedloopoptimizationoftranscranialmagneticstimulationwithelectroencephalographyfeedback AT lioumispantelis closedloopoptimizationoftranscranialmagneticstimulationwithelectroencephalographyfeedback AT metsomaajohanna closedloopoptimizationoftranscranialmagneticstimulationwithelectroencephalographyfeedback AT souzavictorh closedloopoptimizationoftranscranialmagneticstimulationwithelectroencephalographyfeedback AT sinisaloheikki closedloopoptimizationoftranscranialmagneticstimulationwithelectroencephalographyfeedback AT stenroosmatti closedloopoptimizationoftranscranialmagneticstimulationwithelectroencephalographyfeedback AT sarvasjukka closedloopoptimizationoftranscranialmagneticstimulationwithelectroencephalographyfeedback AT ilmoniemiristoj closedloopoptimizationoftranscranialmagneticstimulationwithelectroencephalographyfeedback |