Cargando…

Fluorescence grid analysis for the evaluation of piecemeal surgery in sinonasal inverted papilloma: a proof-of-concept study

PURPOSE: Local recurrence occurs in ~ 19% of sinonasal inverted papilloma (SNIP) surgeries and is strongly associated with incomplete resection. During surgery, it is technically challenging to visualize and resect all SNIP tissue in this anatomically complex area. Proteins that are overexpressed in...

Descripción completa

Detalles Bibliográficos
Autores principales: Vonk, J, Voskuil, FJ, de Wit, JG, Heeman, WT, Nagengast, WB, van Dam, GM, Feijen, RA, Korsten-Meijer, AGW, van der Vegt, B, Witjes, MJH
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8940828/
https://www.ncbi.nlm.nih.gov/pubmed/34738141
http://dx.doi.org/10.1007/s00259-021-05567-x
_version_ 1784672982046605312
author Vonk, J
Voskuil, FJ
de Wit, JG
Heeman, WT
Nagengast, WB
van Dam, GM
Feijen, RA
Korsten-Meijer, AGW
van der Vegt, B
Witjes, MJH
author_facet Vonk, J
Voskuil, FJ
de Wit, JG
Heeman, WT
Nagengast, WB
van Dam, GM
Feijen, RA
Korsten-Meijer, AGW
van der Vegt, B
Witjes, MJH
author_sort Vonk, J
collection PubMed
description PURPOSE: Local recurrence occurs in ~ 19% of sinonasal inverted papilloma (SNIP) surgeries and is strongly associated with incomplete resection. During surgery, it is technically challenging to visualize and resect all SNIP tissue in this anatomically complex area. Proteins that are overexpressed in SNIP, such as vascular endothelial growth factor (VEGF), may serve as a target for fluorescence molecular imaging to guide surgical removal of SNIP. A proof-of-concept study was performed to investigate if the VEGF-targeted near-infrared fluorescent tracer bevacizumab-800CW specifically localizes in SNIP and whether it could be used as a clinical tool to guide SNIP surgery. METHODS: In five patients diagnosed with SNIP, 10 mg of bevacizumab-800CW was intravenously administered 3 days prior to surgery. Fluorescence molecular imaging was performed in vivo during surgery and ex vivo during the processing of the surgical specimen. Fluorescence signals were correlated with final histopathology and VEGF-A immunohistochemistry. We introduced a fluorescence grid analysis to assess the fluorescence signal in individual tissue fragments, due to the nature of the surgical procedure (i.e., piecemeal resection) allowing the detection of small SNIP residues and location of the tracer ex vivo. RESULTS: In all patients, fluorescence signal was detected in vivo during endoscopic SNIP surgery. Using ex vivo fluorescence grid analysis, we were able to correlate bevacizumab-800CW fluorescence of individual tissue fragments with final histopathology. Fluorescence grid analysis showed substantial variability in mean fluorescence intensity (FI(mean)), with SNIP tissue showing a median FI(mean) of 77.54 (IQR 50.47–112.30) compared to 35.99 (IQR 21.48–57.81) in uninvolved tissue (p < 0.0001), although the diagnostic ability was limited with an area under the curve of 0.78. CONCLUSIONS: A fluorescence grid analysis could serve as a valid method to evaluate fluorescence molecular imaging in piecemeal surgeries. As such, although substantial differences were observed in fluorescence intensities, VEGF-A may not be the ideal target for SNIP surgery. TRIAL REGISTRATION: NCT03925285. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00259-021-05567-x.
format Online
Article
Text
id pubmed-8940828
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-89408282022-04-07 Fluorescence grid analysis for the evaluation of piecemeal surgery in sinonasal inverted papilloma: a proof-of-concept study Vonk, J Voskuil, FJ de Wit, JG Heeman, WT Nagengast, WB van Dam, GM Feijen, RA Korsten-Meijer, AGW van der Vegt, B Witjes, MJH Eur J Nucl Med Mol Imaging Original Article PURPOSE: Local recurrence occurs in ~ 19% of sinonasal inverted papilloma (SNIP) surgeries and is strongly associated with incomplete resection. During surgery, it is technically challenging to visualize and resect all SNIP tissue in this anatomically complex area. Proteins that are overexpressed in SNIP, such as vascular endothelial growth factor (VEGF), may serve as a target for fluorescence molecular imaging to guide surgical removal of SNIP. A proof-of-concept study was performed to investigate if the VEGF-targeted near-infrared fluorescent tracer bevacizumab-800CW specifically localizes in SNIP and whether it could be used as a clinical tool to guide SNIP surgery. METHODS: In five patients diagnosed with SNIP, 10 mg of bevacizumab-800CW was intravenously administered 3 days prior to surgery. Fluorescence molecular imaging was performed in vivo during surgery and ex vivo during the processing of the surgical specimen. Fluorescence signals were correlated with final histopathology and VEGF-A immunohistochemistry. We introduced a fluorescence grid analysis to assess the fluorescence signal in individual tissue fragments, due to the nature of the surgical procedure (i.e., piecemeal resection) allowing the detection of small SNIP residues and location of the tracer ex vivo. RESULTS: In all patients, fluorescence signal was detected in vivo during endoscopic SNIP surgery. Using ex vivo fluorescence grid analysis, we were able to correlate bevacizumab-800CW fluorescence of individual tissue fragments with final histopathology. Fluorescence grid analysis showed substantial variability in mean fluorescence intensity (FI(mean)), with SNIP tissue showing a median FI(mean) of 77.54 (IQR 50.47–112.30) compared to 35.99 (IQR 21.48–57.81) in uninvolved tissue (p < 0.0001), although the diagnostic ability was limited with an area under the curve of 0.78. CONCLUSIONS: A fluorescence grid analysis could serve as a valid method to evaluate fluorescence molecular imaging in piecemeal surgeries. As such, although substantial differences were observed in fluorescence intensities, VEGF-A may not be the ideal target for SNIP surgery. TRIAL REGISTRATION: NCT03925285. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00259-021-05567-x. Springer Berlin Heidelberg 2021-11-05 2022 /pmc/articles/PMC8940828/ /pubmed/34738141 http://dx.doi.org/10.1007/s00259-021-05567-x Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Vonk, J
Voskuil, FJ
de Wit, JG
Heeman, WT
Nagengast, WB
van Dam, GM
Feijen, RA
Korsten-Meijer, AGW
van der Vegt, B
Witjes, MJH
Fluorescence grid analysis for the evaluation of piecemeal surgery in sinonasal inverted papilloma: a proof-of-concept study
title Fluorescence grid analysis for the evaluation of piecemeal surgery in sinonasal inverted papilloma: a proof-of-concept study
title_full Fluorescence grid analysis for the evaluation of piecemeal surgery in sinonasal inverted papilloma: a proof-of-concept study
title_fullStr Fluorescence grid analysis for the evaluation of piecemeal surgery in sinonasal inverted papilloma: a proof-of-concept study
title_full_unstemmed Fluorescence grid analysis for the evaluation of piecemeal surgery in sinonasal inverted papilloma: a proof-of-concept study
title_short Fluorescence grid analysis for the evaluation of piecemeal surgery in sinonasal inverted papilloma: a proof-of-concept study
title_sort fluorescence grid analysis for the evaluation of piecemeal surgery in sinonasal inverted papilloma: a proof-of-concept study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8940828/
https://www.ncbi.nlm.nih.gov/pubmed/34738141
http://dx.doi.org/10.1007/s00259-021-05567-x
work_keys_str_mv AT vonkj fluorescencegridanalysisfortheevaluationofpiecemealsurgeryinsinonasalinvertedpapillomaaproofofconceptstudy
AT voskuilfj fluorescencegridanalysisfortheevaluationofpiecemealsurgeryinsinonasalinvertedpapillomaaproofofconceptstudy
AT dewitjg fluorescencegridanalysisfortheevaluationofpiecemealsurgeryinsinonasalinvertedpapillomaaproofofconceptstudy
AT heemanwt fluorescencegridanalysisfortheevaluationofpiecemealsurgeryinsinonasalinvertedpapillomaaproofofconceptstudy
AT nagengastwb fluorescencegridanalysisfortheevaluationofpiecemealsurgeryinsinonasalinvertedpapillomaaproofofconceptstudy
AT vandamgm fluorescencegridanalysisfortheevaluationofpiecemealsurgeryinsinonasalinvertedpapillomaaproofofconceptstudy
AT feijenra fluorescencegridanalysisfortheevaluationofpiecemealsurgeryinsinonasalinvertedpapillomaaproofofconceptstudy
AT korstenmeijeragw fluorescencegridanalysisfortheevaluationofpiecemealsurgeryinsinonasalinvertedpapillomaaproofofconceptstudy
AT vandervegtb fluorescencegridanalysisfortheevaluationofpiecemealsurgeryinsinonasalinvertedpapillomaaproofofconceptstudy
AT witjesmjh fluorescencegridanalysisfortheevaluationofpiecemealsurgeryinsinonasalinvertedpapillomaaproofofconceptstudy