Cargando…

Low profile external fixation using locking compression plate as treatment option for management of soft tissue problem in open tibia fracture grade IIIA: A case series

INTRODUCTION: External fixators are the most common fixation method for fractures with substantial soft tissue compromise. Nonetheless, the frames used are bulky, uncomfortable, and cumbersome to patients. Using locking compression plate (LCP) as an external fixator (low profile external fixation/LP...

Descripción completa

Detalles Bibliográficos
Autores principales: Hidayat, Luthfi, Triangga, Aditya Fuad Robby, Cein, Caesarean Rayhan, Irfantian, Ardicho, Rahayu, Bernadeta Fuad Paramita, Resubun, Alan Philips, Magetsari, Rahadyan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8941166/
https://www.ncbi.nlm.nih.gov/pubmed/35306335
http://dx.doi.org/10.1016/j.ijscr.2022.106882
_version_ 1784673052212068352
author Hidayat, Luthfi
Triangga, Aditya Fuad Robby
Cein, Caesarean Rayhan
Irfantian, Ardicho
Rahayu, Bernadeta Fuad Paramita
Resubun, Alan Philips
Magetsari, Rahadyan
author_facet Hidayat, Luthfi
Triangga, Aditya Fuad Robby
Cein, Caesarean Rayhan
Irfantian, Ardicho
Rahayu, Bernadeta Fuad Paramita
Resubun, Alan Philips
Magetsari, Rahadyan
author_sort Hidayat, Luthfi
collection PubMed
description INTRODUCTION: External fixators are the most common fixation method for fractures with substantial soft tissue compromise. Nonetheless, the frames used are bulky, uncomfortable, and cumbersome to patients. Using locking compression plate (LCP) as an external fixator (low profile external fixation/LPEF) owns the same properties as standard external fixators but may overcome disadvantages because of its low-profile frame. This case series aims to evaluate the results of LPEF for the management of tibia fracture with soft tissue compromise. PRESENTATION OF CASES: We reviewed five patients at our centers who underwent surgery in 2020 with the application of LPEF. These patients had grade IIIA open tibia fracture with respective complications. The follow-up duration was 6 months post-operative in which we assessed Southampton Wound Assessment Scale (SWAS), laboratory infection markers, radiographic evaluation, and the Lower Extremity Functional Scale (LEFS). The results showed all wounds healed and cases with infection showed tendency of resolving, alongside varying degree of bone healing. The implant was well tolerated for patients and the functional outcome was overall good (mean LEFS: 71.26%). DISCUSSION: The LPEF is fortuitously lightweight and more convenient for patients to ambulate, thus the compliance of early functional exercise is more likely to happen. CONCLUSION: Application of LPEF can be considered as an option for treating soft tissue compromised tibia fracture. In our experience, it is low profile, more acceptable to the patients, and displayed favorable outcomes especially in terms of soft tissue or skin healing and infection resolution.
format Online
Article
Text
id pubmed-8941166
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-89411662022-03-24 Low profile external fixation using locking compression plate as treatment option for management of soft tissue problem in open tibia fracture grade IIIA: A case series Hidayat, Luthfi Triangga, Aditya Fuad Robby Cein, Caesarean Rayhan Irfantian, Ardicho Rahayu, Bernadeta Fuad Paramita Resubun, Alan Philips Magetsari, Rahadyan Int J Surg Case Rep Case Report INTRODUCTION: External fixators are the most common fixation method for fractures with substantial soft tissue compromise. Nonetheless, the frames used are bulky, uncomfortable, and cumbersome to patients. Using locking compression plate (LCP) as an external fixator (low profile external fixation/LPEF) owns the same properties as standard external fixators but may overcome disadvantages because of its low-profile frame. This case series aims to evaluate the results of LPEF for the management of tibia fracture with soft tissue compromise. PRESENTATION OF CASES: We reviewed five patients at our centers who underwent surgery in 2020 with the application of LPEF. These patients had grade IIIA open tibia fracture with respective complications. The follow-up duration was 6 months post-operative in which we assessed Southampton Wound Assessment Scale (SWAS), laboratory infection markers, radiographic evaluation, and the Lower Extremity Functional Scale (LEFS). The results showed all wounds healed and cases with infection showed tendency of resolving, alongside varying degree of bone healing. The implant was well tolerated for patients and the functional outcome was overall good (mean LEFS: 71.26%). DISCUSSION: The LPEF is fortuitously lightweight and more convenient for patients to ambulate, thus the compliance of early functional exercise is more likely to happen. CONCLUSION: Application of LPEF can be considered as an option for treating soft tissue compromised tibia fracture. In our experience, it is low profile, more acceptable to the patients, and displayed favorable outcomes especially in terms of soft tissue or skin healing and infection resolution. Elsevier 2022-02-26 /pmc/articles/PMC8941166/ /pubmed/35306335 http://dx.doi.org/10.1016/j.ijscr.2022.106882 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Hidayat, Luthfi
Triangga, Aditya Fuad Robby
Cein, Caesarean Rayhan
Irfantian, Ardicho
Rahayu, Bernadeta Fuad Paramita
Resubun, Alan Philips
Magetsari, Rahadyan
Low profile external fixation using locking compression plate as treatment option for management of soft tissue problem in open tibia fracture grade IIIA: A case series
title Low profile external fixation using locking compression plate as treatment option for management of soft tissue problem in open tibia fracture grade IIIA: A case series
title_full Low profile external fixation using locking compression plate as treatment option for management of soft tissue problem in open tibia fracture grade IIIA: A case series
title_fullStr Low profile external fixation using locking compression plate as treatment option for management of soft tissue problem in open tibia fracture grade IIIA: A case series
title_full_unstemmed Low profile external fixation using locking compression plate as treatment option for management of soft tissue problem in open tibia fracture grade IIIA: A case series
title_short Low profile external fixation using locking compression plate as treatment option for management of soft tissue problem in open tibia fracture grade IIIA: A case series
title_sort low profile external fixation using locking compression plate as treatment option for management of soft tissue problem in open tibia fracture grade iiia: a case series
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8941166/
https://www.ncbi.nlm.nih.gov/pubmed/35306335
http://dx.doi.org/10.1016/j.ijscr.2022.106882
work_keys_str_mv AT hidayatluthfi lowprofileexternalfixationusinglockingcompressionplateastreatmentoptionformanagementofsofttissueprobleminopentibiafracturegradeiiiaacaseseries
AT trianggaadityafuadrobby lowprofileexternalfixationusinglockingcompressionplateastreatmentoptionformanagementofsofttissueprobleminopentibiafracturegradeiiiaacaseseries
AT ceincaesareanrayhan lowprofileexternalfixationusinglockingcompressionplateastreatmentoptionformanagementofsofttissueprobleminopentibiafracturegradeiiiaacaseseries
AT irfantianardicho lowprofileexternalfixationusinglockingcompressionplateastreatmentoptionformanagementofsofttissueprobleminopentibiafracturegradeiiiaacaseseries
AT rahayubernadetafuadparamita lowprofileexternalfixationusinglockingcompressionplateastreatmentoptionformanagementofsofttissueprobleminopentibiafracturegradeiiiaacaseseries
AT resubunalanphilips lowprofileexternalfixationusinglockingcompressionplateastreatmentoptionformanagementofsofttissueprobleminopentibiafracturegradeiiiaacaseseries
AT magetsarirahadyan lowprofileexternalfixationusinglockingcompressionplateastreatmentoptionformanagementofsofttissueprobleminopentibiafracturegradeiiiaacaseseries