EMI radiation of power transmission lines in Malaysia

Background: There has been rising concern amongst the public regarding their home's proximity to high tension power transmission lines. The primary cause of fear is the impact of the electromagnetic interference (EMI) radiation on the nearby occupants' health. Despite the presence of natio...

Descripción completa

Detalles Bibliográficos
Autores principales: Fikry, Azhan, Lim, Siow Chun, Ab Kadir, Mohd Zainal Abidin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: F1000 Research Limited 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8941290/
https://www.ncbi.nlm.nih.gov/pubmed/35387277
http://dx.doi.org/10.12688/f1000research.73067.2
_version_ 1784673079820025856
author Fikry, Azhan
Lim, Siow Chun
Ab Kadir, Mohd Zainal Abidin
author_facet Fikry, Azhan
Lim, Siow Chun
Ab Kadir, Mohd Zainal Abidin
author_sort Fikry, Azhan
collection PubMed
description Background: There has been rising concern amongst the public regarding their home's proximity to high tension power transmission lines. The primary cause of fear is the impact of the electromagnetic interference (EMI) radiation on the nearby occupants' health. Despite the presence of national permissible limits of EMI radiation, there is still lack of information with regards to the EMI radiation of the types of power lines configuration in Malaysia. Methods: The electric and magnetic fields of several selected power transmission lines were simulated using the EMFACDC software program from the recommendation ITU-T K.90. Five types of power transmission lines available in Malaysia are considered. Results: It was found that the simulated electric and magnetic field levels at all the power lines' right of way (ROW) boundary complies with the prescribed exposure limit. However, the electromagnetic fields (EMF) level increases significantly as the separation distance is reduced from 30m. For a more conservative approach, the ROW can be set at 30m across all transmission voltage level and corridor area condition. Conclusion: It can be concluded that Malaysia's power transmission lines are within the prescribed exposure limits. To further minimize the electric and magnetic field level, it is recommended that the residential building should be built at least 30 meters away from the power transmission lines, especially for the 275kV double circuit, 275/132kV quadruple circuit, and 500kV double circuit lines.
format Online
Article
Text
id pubmed-8941290
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher F1000 Research Limited
record_format MEDLINE/PubMed
spelling pubmed-89412902022-04-05 EMI radiation of power transmission lines in Malaysia Fikry, Azhan Lim, Siow Chun Ab Kadir, Mohd Zainal Abidin F1000Res Research Article Background: There has been rising concern amongst the public regarding their home's proximity to high tension power transmission lines. The primary cause of fear is the impact of the electromagnetic interference (EMI) radiation on the nearby occupants' health. Despite the presence of national permissible limits of EMI radiation, there is still lack of information with regards to the EMI radiation of the types of power lines configuration in Malaysia. Methods: The electric and magnetic fields of several selected power transmission lines were simulated using the EMFACDC software program from the recommendation ITU-T K.90. Five types of power transmission lines available in Malaysia are considered. Results: It was found that the simulated electric and magnetic field levels at all the power lines' right of way (ROW) boundary complies with the prescribed exposure limit. However, the electromagnetic fields (EMF) level increases significantly as the separation distance is reduced from 30m. For a more conservative approach, the ROW can be set at 30m across all transmission voltage level and corridor area condition. Conclusion: It can be concluded that Malaysia's power transmission lines are within the prescribed exposure limits. To further minimize the electric and magnetic field level, it is recommended that the residential building should be built at least 30 meters away from the power transmission lines, especially for the 275kV double circuit, 275/132kV quadruple circuit, and 500kV double circuit lines. F1000 Research Limited 2022-02-24 /pmc/articles/PMC8941290/ /pubmed/35387277 http://dx.doi.org/10.12688/f1000research.73067.2 Text en Copyright: © 2022 Fikry A et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Fikry, Azhan
Lim, Siow Chun
Ab Kadir, Mohd Zainal Abidin
EMI radiation of power transmission lines in Malaysia
title EMI radiation of power transmission lines in Malaysia
title_full EMI radiation of power transmission lines in Malaysia
title_fullStr EMI radiation of power transmission lines in Malaysia
title_full_unstemmed EMI radiation of power transmission lines in Malaysia
title_short EMI radiation of power transmission lines in Malaysia
title_sort emi radiation of power transmission lines in malaysia
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8941290/
https://www.ncbi.nlm.nih.gov/pubmed/35387277
http://dx.doi.org/10.12688/f1000research.73067.2
work_keys_str_mv AT fikryazhan emiradiationofpowertransmissionlinesinmalaysia
AT limsiowchun emiradiationofpowertransmissionlinesinmalaysia
AT abkadirmohdzainalabidin emiradiationofpowertransmissionlinesinmalaysia