Cargando…

Passive high-frequency microrheology of blood

Indicative of various pathologies, blood properties are under intense scrutiny. The hemorheological characteristics are traditionally gauged by bulk, low-frequency indicators that average out critical information about the complex, multi-scale, and multi-component structure. In particular, one canno...

Descripción completa

Detalles Bibliográficos
Autores principales: Guzman-Sepulveda, Jose Rafael, Batarseh, Mahed, Wu, Ruitao, DeCampli, William M., Dogariu, Aristide
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8941587/
https://www.ncbi.nlm.nih.gov/pubmed/35279707
http://dx.doi.org/10.1039/d1sm01726h
_version_ 1784673143759044608
author Guzman-Sepulveda, Jose Rafael
Batarseh, Mahed
Wu, Ruitao
DeCampli, William M.
Dogariu, Aristide
author_facet Guzman-Sepulveda, Jose Rafael
Batarseh, Mahed
Wu, Ruitao
DeCampli, William M.
Dogariu, Aristide
author_sort Guzman-Sepulveda, Jose Rafael
collection PubMed
description Indicative of various pathologies, blood properties are under intense scrutiny. The hemorheological characteristics are traditionally gauged by bulk, low-frequency indicators that average out critical information about the complex, multi-scale, and multi-component structure. In particular, one cannot discriminate between the erythrocytes contribution to global rheology and the impact of plasma. Nevertheless, in their fast stochastic movement, before they encounter each other, the erythrocytes probe the subtle viscoelasticity of their protein-rich environment. Thus, if these short time scales can be resolved experimentally, the plasma properties could be determined without having to separate the blood components; the blood is practically testing itself. This microrheological description of blood plasma provides a direct link between the composition of whole blood and its coagulability status. We present a parametric model for the viscoelasticity of plasma, which is probed by the erythrocytes over frequency ranges of kilohertz in a picoliter-sized volume. The model is validated both in vitro, using artificial hemo-systems where the composition is controlled, as well as on whole blood where continuous measurements provide real-time information. We also discuss the possibility of using this passive microrheology as an in vivo assay for clinically relevant situations where the blood clotting condition must be observed and managed continuously for diagnosis or during therapeutic procedures at different stages of hemostatic and thrombotic processes.
format Online
Article
Text
id pubmed-8941587
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-89415872022-04-14 Passive high-frequency microrheology of blood Guzman-Sepulveda, Jose Rafael Batarseh, Mahed Wu, Ruitao DeCampli, William M. Dogariu, Aristide Soft Matter Chemistry Indicative of various pathologies, blood properties are under intense scrutiny. The hemorheological characteristics are traditionally gauged by bulk, low-frequency indicators that average out critical information about the complex, multi-scale, and multi-component structure. In particular, one cannot discriminate between the erythrocytes contribution to global rheology and the impact of plasma. Nevertheless, in their fast stochastic movement, before they encounter each other, the erythrocytes probe the subtle viscoelasticity of their protein-rich environment. Thus, if these short time scales can be resolved experimentally, the plasma properties could be determined without having to separate the blood components; the blood is practically testing itself. This microrheological description of blood plasma provides a direct link between the composition of whole blood and its coagulability status. We present a parametric model for the viscoelasticity of plasma, which is probed by the erythrocytes over frequency ranges of kilohertz in a picoliter-sized volume. The model is validated both in vitro, using artificial hemo-systems where the composition is controlled, as well as on whole blood where continuous measurements provide real-time information. We also discuss the possibility of using this passive microrheology as an in vivo assay for clinically relevant situations where the blood clotting condition must be observed and managed continuously for diagnosis or during therapeutic procedures at different stages of hemostatic and thrombotic processes. The Royal Society of Chemistry 2022-03-13 /pmc/articles/PMC8941587/ /pubmed/35279707 http://dx.doi.org/10.1039/d1sm01726h Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/
spellingShingle Chemistry
Guzman-Sepulveda, Jose Rafael
Batarseh, Mahed
Wu, Ruitao
DeCampli, William M.
Dogariu, Aristide
Passive high-frequency microrheology of blood
title Passive high-frequency microrheology of blood
title_full Passive high-frequency microrheology of blood
title_fullStr Passive high-frequency microrheology of blood
title_full_unstemmed Passive high-frequency microrheology of blood
title_short Passive high-frequency microrheology of blood
title_sort passive high-frequency microrheology of blood
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8941587/
https://www.ncbi.nlm.nih.gov/pubmed/35279707
http://dx.doi.org/10.1039/d1sm01726h
work_keys_str_mv AT guzmansepulvedajoserafael passivehighfrequencymicrorheologyofblood
AT batarsehmahed passivehighfrequencymicrorheologyofblood
AT wuruitao passivehighfrequencymicrorheologyofblood
AT decampliwilliamm passivehighfrequencymicrorheologyofblood
AT dogariuaristide passivehighfrequencymicrorheologyofblood