Cargando…

Quantifying the confounding effect of pigmentation on measured skin tissue optical properties: a comparison of colorimetry with spatial frequency domain imaging

SIGNIFICANCE: Spatial frequency domain imaging (SFDI) is a wide-field diffuse optical imaging technique for separately quantifying tissue reduced scattering ([Formula: see text]) and absorption ([Formula: see text]) coefficients at multiple wavelengths, providing wide potential utility for clinical...

Descripción completa

Detalles Bibliográficos
Autores principales: Phan, Thinh, Rowland, Rebecca, Ponticorvo, Adrien, Le, Binh Cong, Sharif, Seyed A., Kennedy, Gordon T., Wilson, Robert H., Durkin, Anthony J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Society of Photo-Optical Instrumentation Engineers 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8942554/
https://www.ncbi.nlm.nih.gov/pubmed/35324096
http://dx.doi.org/10.1117/1.JBO.27.3.036002
_version_ 1784673328297934848
author Phan, Thinh
Rowland, Rebecca
Ponticorvo, Adrien
Le, Binh Cong
Sharif, Seyed A.
Kennedy, Gordon T.
Wilson, Robert H.
Durkin, Anthony J.
author_facet Phan, Thinh
Rowland, Rebecca
Ponticorvo, Adrien
Le, Binh Cong
Sharif, Seyed A.
Kennedy, Gordon T.
Wilson, Robert H.
Durkin, Anthony J.
author_sort Phan, Thinh
collection PubMed
description SIGNIFICANCE: Spatial frequency domain imaging (SFDI) is a wide-field diffuse optical imaging technique for separately quantifying tissue reduced scattering ([Formula: see text]) and absorption ([Formula: see text]) coefficients at multiple wavelengths, providing wide potential utility for clinical applications such as burn wound characterization and cancer detection. However, measured [Formula: see text] and [Formula: see text] can be confounded by absorption from melanin in patients with highly pigmented skin. This issue arises because epidermal melanin is highly absorbing for visible wavelengths and standard homogeneous light–tissue interaction models do not properly account for this complexity. Tristimulus colorimetry (which quantifies pigmentation using the [Formula: see text] “lightness” parameter) can provide a point of comparison between [Formula: see text] , [Formula: see text] , and skin pigmentation. AIM: We systematically compare SFDI and colorimetry parameters to quantify confounding effects of pigmentation on measured skin [Formula: see text] and [Formula: see text]. We assess the correlation between SFDI and colorimetry parameters as a function of wavelength. APPROACH: [Formula: see text] and [Formula: see text] from the palm and ventral forearm were measured for 15 healthy subjects with a wide range of skin pigmentation levels (Fitzpatrick types I to VI) using a Reflect RS(®) (Modulim, Inc., Irvine, California) SFDI instrument (eight wavelengths, 471 to 851 nm). [Formula: see text] was measured using a Chroma Meter CR-400 (Konica Minolta Sensing, Inc., Tokyo). Linear correlation coefficients were calculated between [Formula: see text] and [Formula: see text] and between [Formula: see text] and [Formula: see text] at all wavelengths. RESULTS: For the ventral forearm, strong linear correlations between measured [Formula: see text] and [Formula: see text] values were observed at shorter wavelengths ([Formula: see text] at [Formula: see text]), where absorption from melanin confounded the measured [Formula: see text]. These correlations were weaker for the palm ([Formula: see text] at [Formula: see text]), which has less melanin than the forearm. Similar relationships were observed between [Formula: see text] and [Formula: see text]. CONCLUSIONS: We quantified the effects of epidermal melanin on skin [Formula: see text] and [Formula: see text] measured with SFDI. This information may help characterize and correct pigmentation-related inaccuracies in SFDI skin measurements.
format Online
Article
Text
id pubmed-8942554
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Society of Photo-Optical Instrumentation Engineers
record_format MEDLINE/PubMed
spelling pubmed-89425542022-03-29 Quantifying the confounding effect of pigmentation on measured skin tissue optical properties: a comparison of colorimetry with spatial frequency domain imaging Phan, Thinh Rowland, Rebecca Ponticorvo, Adrien Le, Binh Cong Sharif, Seyed A. Kennedy, Gordon T. Wilson, Robert H. Durkin, Anthony J. J Biomed Opt Imaging SIGNIFICANCE: Spatial frequency domain imaging (SFDI) is a wide-field diffuse optical imaging technique for separately quantifying tissue reduced scattering ([Formula: see text]) and absorption ([Formula: see text]) coefficients at multiple wavelengths, providing wide potential utility for clinical applications such as burn wound characterization and cancer detection. However, measured [Formula: see text] and [Formula: see text] can be confounded by absorption from melanin in patients with highly pigmented skin. This issue arises because epidermal melanin is highly absorbing for visible wavelengths and standard homogeneous light–tissue interaction models do not properly account for this complexity. Tristimulus colorimetry (which quantifies pigmentation using the [Formula: see text] “lightness” parameter) can provide a point of comparison between [Formula: see text] , [Formula: see text] , and skin pigmentation. AIM: We systematically compare SFDI and colorimetry parameters to quantify confounding effects of pigmentation on measured skin [Formula: see text] and [Formula: see text]. We assess the correlation between SFDI and colorimetry parameters as a function of wavelength. APPROACH: [Formula: see text] and [Formula: see text] from the palm and ventral forearm were measured for 15 healthy subjects with a wide range of skin pigmentation levels (Fitzpatrick types I to VI) using a Reflect RS(®) (Modulim, Inc., Irvine, California) SFDI instrument (eight wavelengths, 471 to 851 nm). [Formula: see text] was measured using a Chroma Meter CR-400 (Konica Minolta Sensing, Inc., Tokyo). Linear correlation coefficients were calculated between [Formula: see text] and [Formula: see text] and between [Formula: see text] and [Formula: see text] at all wavelengths. RESULTS: For the ventral forearm, strong linear correlations between measured [Formula: see text] and [Formula: see text] values were observed at shorter wavelengths ([Formula: see text] at [Formula: see text]), where absorption from melanin confounded the measured [Formula: see text]. These correlations were weaker for the palm ([Formula: see text] at [Formula: see text]), which has less melanin than the forearm. Similar relationships were observed between [Formula: see text] and [Formula: see text]. CONCLUSIONS: We quantified the effects of epidermal melanin on skin [Formula: see text] and [Formula: see text] measured with SFDI. This information may help characterize and correct pigmentation-related inaccuracies in SFDI skin measurements. Society of Photo-Optical Instrumentation Engineers 2022-03-23 2022-03 /pmc/articles/PMC8942554/ /pubmed/35324096 http://dx.doi.org/10.1117/1.JBO.27.3.036002 Text en © 2022 The Authors https://creativecommons.org/licenses/by/4.0/Published by SPIE under a Creative Commons Attribution 4.0 International License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
spellingShingle Imaging
Phan, Thinh
Rowland, Rebecca
Ponticorvo, Adrien
Le, Binh Cong
Sharif, Seyed A.
Kennedy, Gordon T.
Wilson, Robert H.
Durkin, Anthony J.
Quantifying the confounding effect of pigmentation on measured skin tissue optical properties: a comparison of colorimetry with spatial frequency domain imaging
title Quantifying the confounding effect of pigmentation on measured skin tissue optical properties: a comparison of colorimetry with spatial frequency domain imaging
title_full Quantifying the confounding effect of pigmentation on measured skin tissue optical properties: a comparison of colorimetry with spatial frequency domain imaging
title_fullStr Quantifying the confounding effect of pigmentation on measured skin tissue optical properties: a comparison of colorimetry with spatial frequency domain imaging
title_full_unstemmed Quantifying the confounding effect of pigmentation on measured skin tissue optical properties: a comparison of colorimetry with spatial frequency domain imaging
title_short Quantifying the confounding effect of pigmentation on measured skin tissue optical properties: a comparison of colorimetry with spatial frequency domain imaging
title_sort quantifying the confounding effect of pigmentation on measured skin tissue optical properties: a comparison of colorimetry with spatial frequency domain imaging
topic Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8942554/
https://www.ncbi.nlm.nih.gov/pubmed/35324096
http://dx.doi.org/10.1117/1.JBO.27.3.036002
work_keys_str_mv AT phanthinh quantifyingtheconfoundingeffectofpigmentationonmeasuredskintissueopticalpropertiesacomparisonofcolorimetrywithspatialfrequencydomainimaging
AT rowlandrebecca quantifyingtheconfoundingeffectofpigmentationonmeasuredskintissueopticalpropertiesacomparisonofcolorimetrywithspatialfrequencydomainimaging
AT ponticorvoadrien quantifyingtheconfoundingeffectofpigmentationonmeasuredskintissueopticalpropertiesacomparisonofcolorimetrywithspatialfrequencydomainimaging
AT lebinhcong quantifyingtheconfoundingeffectofpigmentationonmeasuredskintissueopticalpropertiesacomparisonofcolorimetrywithspatialfrequencydomainimaging
AT sharifseyeda quantifyingtheconfoundingeffectofpigmentationonmeasuredskintissueopticalpropertiesacomparisonofcolorimetrywithspatialfrequencydomainimaging
AT kennedygordont quantifyingtheconfoundingeffectofpigmentationonmeasuredskintissueopticalpropertiesacomparisonofcolorimetrywithspatialfrequencydomainimaging
AT wilsonroberth quantifyingtheconfoundingeffectofpigmentationonmeasuredskintissueopticalpropertiesacomparisonofcolorimetrywithspatialfrequencydomainimaging
AT durkinanthonyj quantifyingtheconfoundingeffectofpigmentationonmeasuredskintissueopticalpropertiesacomparisonofcolorimetrywithspatialfrequencydomainimaging