Comparison between conventional duplex ultrasonography and the dual-gate Doppler mode for hemodynamic measurements of the carotid arteries

PURPOSE: This study investigated the correlations of hemodynamic parameters measured to quantify stenosis between the gold-standard duplex ultrasonography and the dual-gate Doppler mode. METHODS: Patients examined due to suspicion of carotid artery stenosis or for surveillance of known stenosis were...

Descripción completa

Detalles Bibliográficos
Autores principales: Hersant, Jeanne, Ramondou, Pierre, Douillet, Delphine, Abrard, Stanislas, Vandeputte, Patrick, Lapébie, François-Xavier, Abraham, Pierre, Henni, Samir
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Ultrasound in Medicine 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8942739/
https://www.ncbi.nlm.nih.gov/pubmed/34974673
http://dx.doi.org/10.14366/usg.21175
_version_ 1784673368726831104
author Hersant, Jeanne
Ramondou, Pierre
Douillet, Delphine
Abrard, Stanislas
Vandeputte, Patrick
Lapébie, François-Xavier
Abraham, Pierre
Henni, Samir
author_facet Hersant, Jeanne
Ramondou, Pierre
Douillet, Delphine
Abrard, Stanislas
Vandeputte, Patrick
Lapébie, François-Xavier
Abraham, Pierre
Henni, Samir
author_sort Hersant, Jeanne
collection PubMed
description PURPOSE: This study investigated the correlations of hemodynamic parameters measured to quantify stenosis between the gold-standard duplex ultrasonography and the dual-gate Doppler mode. METHODS: Patients examined due to suspicion of carotid artery stenosis or for surveillance of known stenosis were invited to participate in this prospective single-center study. Upon acceptance, the hemodynamic characteristics of the carotid arteries were determined successively in standard duplex and dual-gate Doppler modes. The correlations between the two modes were analyzed by computing Pearson coefficients (r(2)) and Lin concordance coefficients (ρ(c)). The degree of agreement between the two methods was visualized using Bland-Altman graphical representations. RESULTS: The correlation between internal carotid artery peak systolic velocity measured by standard duplex ultrasonography and dual-gate Doppler mode was good (r(2)=0.642). The same high level of correlation was observed for the carotid ratio (r(2)=0.544). However, the Bland-Altman graphical representation and the Lin concordance coefficients (ρ(c)=0.75 and ρ(c)=0.74 for the internal carotid artery peak systolic velocity and carotid ratio, respectively) showed that a lack of precision generated some discrepancies between the two measurement methods. CONCLUSION: Although some discrepancies were observed, the hemodynamic measurements were closely correlated between the two ultrasonography modes. Therefore, the dual-gate Doppler mode may have obvious advantages over conventional ultrasonography, offering interesting development possibilities.
format Online
Article
Text
id pubmed-8942739
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Korean Society of Ultrasound in Medicine
record_format MEDLINE/PubMed
spelling pubmed-89427392022-04-01 Comparison between conventional duplex ultrasonography and the dual-gate Doppler mode for hemodynamic measurements of the carotid arteries Hersant, Jeanne Ramondou, Pierre Douillet, Delphine Abrard, Stanislas Vandeputte, Patrick Lapébie, François-Xavier Abraham, Pierre Henni, Samir Ultrasonography Original Article PURPOSE: This study investigated the correlations of hemodynamic parameters measured to quantify stenosis between the gold-standard duplex ultrasonography and the dual-gate Doppler mode. METHODS: Patients examined due to suspicion of carotid artery stenosis or for surveillance of known stenosis were invited to participate in this prospective single-center study. Upon acceptance, the hemodynamic characteristics of the carotid arteries were determined successively in standard duplex and dual-gate Doppler modes. The correlations between the two modes were analyzed by computing Pearson coefficients (r(2)) and Lin concordance coefficients (ρ(c)). The degree of agreement between the two methods was visualized using Bland-Altman graphical representations. RESULTS: The correlation between internal carotid artery peak systolic velocity measured by standard duplex ultrasonography and dual-gate Doppler mode was good (r(2)=0.642). The same high level of correlation was observed for the carotid ratio (r(2)=0.544). However, the Bland-Altman graphical representation and the Lin concordance coefficients (ρ(c)=0.75 and ρ(c)=0.74 for the internal carotid artery peak systolic velocity and carotid ratio, respectively) showed that a lack of precision generated some discrepancies between the two measurement methods. CONCLUSION: Although some discrepancies were observed, the hemodynamic measurements were closely correlated between the two ultrasonography modes. Therefore, the dual-gate Doppler mode may have obvious advantages over conventional ultrasonography, offering interesting development possibilities. Korean Society of Ultrasound in Medicine 2022-04 2021-11-10 /pmc/articles/PMC8942739/ /pubmed/34974673 http://dx.doi.org/10.14366/usg.21175 Text en Copyright © 2022 Korean Society of Ultrasound in Medicine (KSUM) https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Hersant, Jeanne
Ramondou, Pierre
Douillet, Delphine
Abrard, Stanislas
Vandeputte, Patrick
Lapébie, François-Xavier
Abraham, Pierre
Henni, Samir
Comparison between conventional duplex ultrasonography and the dual-gate Doppler mode for hemodynamic measurements of the carotid arteries
title Comparison between conventional duplex ultrasonography and the dual-gate Doppler mode for hemodynamic measurements of the carotid arteries
title_full Comparison between conventional duplex ultrasonography and the dual-gate Doppler mode for hemodynamic measurements of the carotid arteries
title_fullStr Comparison between conventional duplex ultrasonography and the dual-gate Doppler mode for hemodynamic measurements of the carotid arteries
title_full_unstemmed Comparison between conventional duplex ultrasonography and the dual-gate Doppler mode for hemodynamic measurements of the carotid arteries
title_short Comparison between conventional duplex ultrasonography and the dual-gate Doppler mode for hemodynamic measurements of the carotid arteries
title_sort comparison between conventional duplex ultrasonography and the dual-gate doppler mode for hemodynamic measurements of the carotid arteries
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8942739/
https://www.ncbi.nlm.nih.gov/pubmed/34974673
http://dx.doi.org/10.14366/usg.21175
work_keys_str_mv AT hersantjeanne comparisonbetweenconventionalduplexultrasonographyandthedualgatedopplermodeforhemodynamicmeasurementsofthecarotidarteries
AT ramondoupierre comparisonbetweenconventionalduplexultrasonographyandthedualgatedopplermodeforhemodynamicmeasurementsofthecarotidarteries
AT douilletdelphine comparisonbetweenconventionalduplexultrasonographyandthedualgatedopplermodeforhemodynamicmeasurementsofthecarotidarteries
AT abrardstanislas comparisonbetweenconventionalduplexultrasonographyandthedualgatedopplermodeforhemodynamicmeasurementsofthecarotidarteries
AT vandeputtepatrick comparisonbetweenconventionalduplexultrasonographyandthedualgatedopplermodeforhemodynamicmeasurementsofthecarotidarteries
AT lapebiefrancoisxavier comparisonbetweenconventionalduplexultrasonographyandthedualgatedopplermodeforhemodynamicmeasurementsofthecarotidarteries
AT abrahampierre comparisonbetweenconventionalduplexultrasonographyandthedualgatedopplermodeforhemodynamicmeasurementsofthecarotidarteries
AT hennisamir comparisonbetweenconventionalduplexultrasonographyandthedualgatedopplermodeforhemodynamicmeasurementsofthecarotidarteries