Cargando…

Diagnostic ability of mid-upper arm circumference-to-length ratio in detecting wasting among infants aged 1–6 months in Ethiopia

Mid-upper arm circumference (MUAC) is an age-sensitive anthropometric measurement in infants. However, exact age is difficult to know, particularly in low-income countries. We evaluated the diagnostic accuracy of an age-independent mid-upper arm circumference-to-length (MUAC/L) ratio measurement in...

Descripción completa

Detalles Bibliográficos
Autores principales: Jima, Beshada Rago, Hassen, Hamid Yimem, Bahwere, Paluku, Gebreyesus, Seifu Hagos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cambridge University Press 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8943582/
https://www.ncbi.nlm.nih.gov/pubmed/35399552
http://dx.doi.org/10.1017/jns.2022.21
_version_ 1784673550491189248
author Jima, Beshada Rago
Hassen, Hamid Yimem
Bahwere, Paluku
Gebreyesus, Seifu Hagos
author_facet Jima, Beshada Rago
Hassen, Hamid Yimem
Bahwere, Paluku
Gebreyesus, Seifu Hagos
author_sort Jima, Beshada Rago
collection PubMed
description Mid-upper arm circumference (MUAC) is an age-sensitive anthropometric measurement in infants. However, exact age is difficult to know, particularly in low-income countries. We evaluated the diagnostic accuracy of an age-independent mid-upper arm circumference-to-length (MUAC/L) ratio measurement in detecting wasting among infants aged 1–6 months in Ethiopia. A facility-based diagnostic accuracy study was conducted on 467 in-patient infants aged 1–6 months from March to May 2019. The receiver operating characteristic (ROC) curve was used to evaluate the ability of MUAC/L to detect wasting. Sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and positive and negative predictive values were calculated. The magnitude of severe wasting was 21⋅6 % and moderate wasting was 13⋅0 %. The area under the ROC curve (AUC) of MUAC/L was 0⋅77 (95 % CI 0⋅73, 0⋅81) for detecting moderate wasting and 0⋅92 (95 % CI 0⋅89, 0⋅94) for detecting severe wasting. MUAC/L had a sensitivity of 91⋅1 % (95 % CI 81⋅3, 94⋅4), a specificity of 84⋅7 % (95 % CI 80⋅6, 88⋅2), a positive likelihood ratio of 5⋅82 (95 % CI 4⋅53, 7⋅48) and a negative likelihood ratio of 0⋅13 (95 % CI 0⋅07, 0⋅22) in total infants. The optimal MUAC/L cut-off was <0⋅190 for boys and <0⋅185 for girls. MUAC/L had an AUC of 0⋅77 and 0⋅92 in predicting moderate and severe wasting in infants aged 1–6 months, respectively. Using MUAC/L to treat Ethiopian infants with severe wasting and infants with similar characteristics in other countries could improve treatment coverage.
format Online
Article
Text
id pubmed-8943582
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Cambridge University Press
record_format MEDLINE/PubMed
spelling pubmed-89435822022-04-08 Diagnostic ability of mid-upper arm circumference-to-length ratio in detecting wasting among infants aged 1–6 months in Ethiopia Jima, Beshada Rago Hassen, Hamid Yimem Bahwere, Paluku Gebreyesus, Seifu Hagos J Nutr Sci Research Article Mid-upper arm circumference (MUAC) is an age-sensitive anthropometric measurement in infants. However, exact age is difficult to know, particularly in low-income countries. We evaluated the diagnostic accuracy of an age-independent mid-upper arm circumference-to-length (MUAC/L) ratio measurement in detecting wasting among infants aged 1–6 months in Ethiopia. A facility-based diagnostic accuracy study was conducted on 467 in-patient infants aged 1–6 months from March to May 2019. The receiver operating characteristic (ROC) curve was used to evaluate the ability of MUAC/L to detect wasting. Sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and positive and negative predictive values were calculated. The magnitude of severe wasting was 21⋅6 % and moderate wasting was 13⋅0 %. The area under the ROC curve (AUC) of MUAC/L was 0⋅77 (95 % CI 0⋅73, 0⋅81) for detecting moderate wasting and 0⋅92 (95 % CI 0⋅89, 0⋅94) for detecting severe wasting. MUAC/L had a sensitivity of 91⋅1 % (95 % CI 81⋅3, 94⋅4), a specificity of 84⋅7 % (95 % CI 80⋅6, 88⋅2), a positive likelihood ratio of 5⋅82 (95 % CI 4⋅53, 7⋅48) and a negative likelihood ratio of 0⋅13 (95 % CI 0⋅07, 0⋅22) in total infants. The optimal MUAC/L cut-off was <0⋅190 for boys and <0⋅185 for girls. MUAC/L had an AUC of 0⋅77 and 0⋅92 in predicting moderate and severe wasting in infants aged 1–6 months, respectively. Using MUAC/L to treat Ethiopian infants with severe wasting and infants with similar characteristics in other countries could improve treatment coverage. Cambridge University Press 2022-03-21 /pmc/articles/PMC8943582/ /pubmed/35399552 http://dx.doi.org/10.1017/jns.2022.21 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Jima, Beshada Rago
Hassen, Hamid Yimem
Bahwere, Paluku
Gebreyesus, Seifu Hagos
Diagnostic ability of mid-upper arm circumference-to-length ratio in detecting wasting among infants aged 1–6 months in Ethiopia
title Diagnostic ability of mid-upper arm circumference-to-length ratio in detecting wasting among infants aged 1–6 months in Ethiopia
title_full Diagnostic ability of mid-upper arm circumference-to-length ratio in detecting wasting among infants aged 1–6 months in Ethiopia
title_fullStr Diagnostic ability of mid-upper arm circumference-to-length ratio in detecting wasting among infants aged 1–6 months in Ethiopia
title_full_unstemmed Diagnostic ability of mid-upper arm circumference-to-length ratio in detecting wasting among infants aged 1–6 months in Ethiopia
title_short Diagnostic ability of mid-upper arm circumference-to-length ratio in detecting wasting among infants aged 1–6 months in Ethiopia
title_sort diagnostic ability of mid-upper arm circumference-to-length ratio in detecting wasting among infants aged 1–6 months in ethiopia
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8943582/
https://www.ncbi.nlm.nih.gov/pubmed/35399552
http://dx.doi.org/10.1017/jns.2022.21
work_keys_str_mv AT jimabeshadarago diagnosticabilityofmidupperarmcircumferencetolengthratioindetectingwastingamonginfantsaged16monthsinethiopia
AT hassenhamidyimem diagnosticabilityofmidupperarmcircumferencetolengthratioindetectingwastingamonginfantsaged16monthsinethiopia
AT bahwerepaluku diagnosticabilityofmidupperarmcircumferencetolengthratioindetectingwastingamonginfantsaged16monthsinethiopia
AT gebreyesusseifuhagos diagnosticabilityofmidupperarmcircumferencetolengthratioindetectingwastingamonginfantsaged16monthsinethiopia