709 Reconfiguration: Extracorporeal blood purification of a burn patient on ECMO

INTRODUCTION: Patients who require extracorporeal membrane oxygenation (ECMO) have a very high mortality if they develop septic shock. Extracorporeal blood purification has been studied as an adjunct to antimicrobials but has yielded mixed or even disappointing results. The Seraph-100 Microbind Affi...

Descripción completa

Detalles Bibliográficos
Autores principales: Basel, Anthony P, Thomas, Jason, Williams, Alicia M, Stoffel, Steven, Walter, Robert, Mason, Phillip, Britton, Garrett W, Cancio, Leopoldo C
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8945435/
http://dx.doi.org/10.1093/jbcr/irac012.263
_version_ 1784673957822070784
author Basel, Anthony P
Thomas, Jason
Williams, Alicia M
Stoffel, Steven
Walter, Robert
Mason, Phillip
Britton, Garrett W
Cancio, Leopoldo C
author_facet Basel, Anthony P
Thomas, Jason
Williams, Alicia M
Stoffel, Steven
Walter, Robert
Mason, Phillip
Britton, Garrett W
Cancio, Leopoldo C
author_sort Basel, Anthony P
collection PubMed
description INTRODUCTION: Patients who require extracorporeal membrane oxygenation (ECMO) have a very high mortality if they develop septic shock. Extracorporeal blood purification has been studied as an adjunct to antimicrobials but has yielded mixed or even disappointing results. The Seraph-100 Microbind Affinity Blood Filter (ExThera Medical Corporation, Martinez, CA) is currently undergoing clinical trials. The filter consists of polyethylene beads, coated in heparin sulfate, that irreversibly binds bacteria, fungi, viruses, and toxins. Seraph-100 therapy is traditionally delivered through conventional hemodialysis or continuous renal replacement therapy (CRRT), with the filter being placed in-line with these circuits. We present a case of a burn patient on veno-venous (VV) ECMO in septic shock, who was treated with a Seraph filter by connecting it directly to the ECMO circuit. METHODS: We present a case. RESULTS: A 34-year-old male presented with 56% thermal burns and grade 1 inhalation injury from a fuel tank explosion. He underwent a large-volume resuscitation for burn shock with lactated Ringer’s and albumin, receiving 18,152 mL (163 mL/kg) in the first 24 hours. He was placed on CRRT for acute kidney injury and underwent escharotomies of the hands and legs. On day 4, he developed bacteremia, septic shock and progressed to acute respiratory distress syndrome requiring VV ECMO. Extracorporeal blood purification was started via the Seraph-100 filter. Due to limitations of blood flow rates on CRRT, the Seraph-100 filter was added directly into the ECMO circuit. Inflow tubing was connected to an existing port on the oxygenator (Fig 1) and returned to the venous drainage by cutting a new port into the drainage tubing (Fig 2). The filter itself did not require any special configuration or orientation (Fig 3). This configuration allowed for pressures generated by the ECMO circuit to drive blood flow through the Seraph-100 filter (Fig 4). After 6 hours of treatment, vasopressor requirements drastically decreased. CONCLUSIONS: Complications related to the Seraph-100 filter are rare but may include catheter thrombosis. This is typically due to the type of catheter used and/or the blood-flow rate through the filter rather than the filter itself. This issue was avoided with the ECMO configuration. Similarly, clinicians can avoid transient hypotension, blood loss from a clotted circuit, catheter-site bleeding, and other complications frequently associated with a renal replacement circuit.
format Online
Article
Text
id pubmed-8945435
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-89454352022-03-28 709 Reconfiguration: Extracorporeal blood purification of a burn patient on ECMO Basel, Anthony P Thomas, Jason Williams, Alicia M Stoffel, Steven Walter, Robert Mason, Phillip Britton, Garrett W Cancio, Leopoldo C J Burn Care Res Clinical Sciences: Critical Care 4 INTRODUCTION: Patients who require extracorporeal membrane oxygenation (ECMO) have a very high mortality if they develop septic shock. Extracorporeal blood purification has been studied as an adjunct to antimicrobials but has yielded mixed or even disappointing results. The Seraph-100 Microbind Affinity Blood Filter (ExThera Medical Corporation, Martinez, CA) is currently undergoing clinical trials. The filter consists of polyethylene beads, coated in heparin sulfate, that irreversibly binds bacteria, fungi, viruses, and toxins. Seraph-100 therapy is traditionally delivered through conventional hemodialysis or continuous renal replacement therapy (CRRT), with the filter being placed in-line with these circuits. We present a case of a burn patient on veno-venous (VV) ECMO in septic shock, who was treated with a Seraph filter by connecting it directly to the ECMO circuit. METHODS: We present a case. RESULTS: A 34-year-old male presented with 56% thermal burns and grade 1 inhalation injury from a fuel tank explosion. He underwent a large-volume resuscitation for burn shock with lactated Ringer’s and albumin, receiving 18,152 mL (163 mL/kg) in the first 24 hours. He was placed on CRRT for acute kidney injury and underwent escharotomies of the hands and legs. On day 4, he developed bacteremia, septic shock and progressed to acute respiratory distress syndrome requiring VV ECMO. Extracorporeal blood purification was started via the Seraph-100 filter. Due to limitations of blood flow rates on CRRT, the Seraph-100 filter was added directly into the ECMO circuit. Inflow tubing was connected to an existing port on the oxygenator (Fig 1) and returned to the venous drainage by cutting a new port into the drainage tubing (Fig 2). The filter itself did not require any special configuration or orientation (Fig 3). This configuration allowed for pressures generated by the ECMO circuit to drive blood flow through the Seraph-100 filter (Fig 4). After 6 hours of treatment, vasopressor requirements drastically decreased. CONCLUSIONS: Complications related to the Seraph-100 filter are rare but may include catheter thrombosis. This is typically due to the type of catheter used and/or the blood-flow rate through the filter rather than the filter itself. This issue was avoided with the ECMO configuration. Similarly, clinicians can avoid transient hypotension, blood loss from a clotted circuit, catheter-site bleeding, and other complications frequently associated with a renal replacement circuit. Oxford University Press 2022-03-23 /pmc/articles/PMC8945435/ http://dx.doi.org/10.1093/jbcr/irac012.263 Text en © The Author(s) 2022. Published by Oxford University Press on behalf of the American Burn Association. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Sciences: Critical Care 4
Basel, Anthony P
Thomas, Jason
Williams, Alicia M
Stoffel, Steven
Walter, Robert
Mason, Phillip
Britton, Garrett W
Cancio, Leopoldo C
709 Reconfiguration: Extracorporeal blood purification of a burn patient on ECMO
title 709 Reconfiguration: Extracorporeal blood purification of a burn patient on ECMO
title_full 709 Reconfiguration: Extracorporeal blood purification of a burn patient on ECMO
title_fullStr 709 Reconfiguration: Extracorporeal blood purification of a burn patient on ECMO
title_full_unstemmed 709 Reconfiguration: Extracorporeal blood purification of a burn patient on ECMO
title_short 709 Reconfiguration: Extracorporeal blood purification of a burn patient on ECMO
title_sort 709 reconfiguration: extracorporeal blood purification of a burn patient on ecmo
topic Clinical Sciences: Critical Care 4
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8945435/
http://dx.doi.org/10.1093/jbcr/irac012.263
work_keys_str_mv AT baselanthonyp 709reconfigurationextracorporealbloodpurificationofaburnpatientonecmo
AT thomasjason 709reconfigurationextracorporealbloodpurificationofaburnpatientonecmo
AT williamsaliciam 709reconfigurationextracorporealbloodpurificationofaburnpatientonecmo
AT stoffelsteven 709reconfigurationextracorporealbloodpurificationofaburnpatientonecmo
AT walterrobert 709reconfigurationextracorporealbloodpurificationofaburnpatientonecmo
AT masonphillip 709reconfigurationextracorporealbloodpurificationofaburnpatientonecmo
AT brittongarrettw 709reconfigurationextracorporealbloodpurificationofaburnpatientonecmo
AT cancioleopoldoc 709reconfigurationextracorporealbloodpurificationofaburnpatientonecmo