Cargando…

96 Poly-dl-lactide Copolymer-dressing Use on Burn Wounds and Skin Graft Donor Sites - An Institutional Review

INTRODUCTION: In burn surgical care, wound coverage and the corresponding dressing are paired to maximize the ability to promote re-epithelization, minimize pain and patient discomfort, dressing change frequency and overall cost. This dressing, a copolymer material based on DL lactic acid, has been...

Descripción completa

Detalles Bibliográficos
Autores principales: Lagziel, Tomer, Metoyer, Garyn, Kawaji, Qingwen, Akhavan, Arya A, Cox, Carrie A, Caffrey, Julie, Hultman, Charles S, Duraes, Eliana F
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8945437/
http://dx.doi.org/10.1093/jbcr/irac012.098
_version_ 1784673958319095808
author Lagziel, Tomer
Metoyer, Garyn
Kawaji, Qingwen
Akhavan, Arya A
Cox, Carrie A
Caffrey, Julie
Hultman, Charles S
Duraes, Eliana F
author_facet Lagziel, Tomer
Metoyer, Garyn
Kawaji, Qingwen
Akhavan, Arya A
Cox, Carrie A
Caffrey, Julie
Hultman, Charles S
Duraes, Eliana F
author_sort Lagziel, Tomer
collection PubMed
description INTRODUCTION: In burn surgical care, wound coverage and the corresponding dressing are paired to maximize the ability to promote re-epithelization, minimize pain and patient discomfort, dressing change frequency and overall cost. This dressing, a copolymer material based on DL lactic acid, has been described as a reliable alternative dressing for partial thickness burns as well as skin graft donor sites with comparable wound-healing quality and duration. Our aim is to assess outcomes results of this copolymer dressing at our institution, as applied to partial thickness burn wounds and graft donor sites. METHODS: We performed a retrospective analysis of 55 adult patients admitted between January 1, 2020 to August 25, 2021 for the treatment of partial thickness burns that were managed with a poly-DL-lactide copolymer skin substitute at the burn wound and/or autograft donor site. Three study groups were established based on application site: wound only (group 1), donor site only (group 2), and both (group 3). We assessed operative times, infections rates, complications, length of stay, readmission rates, and mortality. RESULTS: Preliminary data of 40 patients shows clinically similar results for analgesic requirements, operative length, and hospital LOS between group 1 and group 3. Group 2 showed higher analgesic requirements, lower operative times, a lower LOS, and lower readmission rates. Group 3 shows higher pain levels and longer operative times, when compared with groups 1 and 2, but lower readmission rates than group 1. CONCLUSIONS: The poly-DL-lactide copolymer skin substitute offers reliable wound coverage for a partial thickness burns while also reducing frequency of dressing changes and associated pain correlating to reduced length of hospital stay and wound healing interval.
format Online
Article
Text
id pubmed-8945437
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-89454372022-03-28 96 Poly-dl-lactide Copolymer-dressing Use on Burn Wounds and Skin Graft Donor Sites - An Institutional Review Lagziel, Tomer Metoyer, Garyn Kawaji, Qingwen Akhavan, Arya A Cox, Carrie A Caffrey, Julie Hultman, Charles S Duraes, Eliana F J Burn Care Res Correlative XII: Clinical Sciences Wounds & Scars 2 INTRODUCTION: In burn surgical care, wound coverage and the corresponding dressing are paired to maximize the ability to promote re-epithelization, minimize pain and patient discomfort, dressing change frequency and overall cost. This dressing, a copolymer material based on DL lactic acid, has been described as a reliable alternative dressing for partial thickness burns as well as skin graft donor sites with comparable wound-healing quality and duration. Our aim is to assess outcomes results of this copolymer dressing at our institution, as applied to partial thickness burn wounds and graft donor sites. METHODS: We performed a retrospective analysis of 55 adult patients admitted between January 1, 2020 to August 25, 2021 for the treatment of partial thickness burns that were managed with a poly-DL-lactide copolymer skin substitute at the burn wound and/or autograft donor site. Three study groups were established based on application site: wound only (group 1), donor site only (group 2), and both (group 3). We assessed operative times, infections rates, complications, length of stay, readmission rates, and mortality. RESULTS: Preliminary data of 40 patients shows clinically similar results for analgesic requirements, operative length, and hospital LOS between group 1 and group 3. Group 2 showed higher analgesic requirements, lower operative times, a lower LOS, and lower readmission rates. Group 3 shows higher pain levels and longer operative times, when compared with groups 1 and 2, but lower readmission rates than group 1. CONCLUSIONS: The poly-DL-lactide copolymer skin substitute offers reliable wound coverage for a partial thickness burns while also reducing frequency of dressing changes and associated pain correlating to reduced length of hospital stay and wound healing interval. Oxford University Press 2022-03-23 /pmc/articles/PMC8945437/ http://dx.doi.org/10.1093/jbcr/irac012.098 Text en © The Author(s) 2022. Published by Oxford University Press on behalf of the American Burn Association. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Correlative XII: Clinical Sciences Wounds & Scars 2
Lagziel, Tomer
Metoyer, Garyn
Kawaji, Qingwen
Akhavan, Arya A
Cox, Carrie A
Caffrey, Julie
Hultman, Charles S
Duraes, Eliana F
96 Poly-dl-lactide Copolymer-dressing Use on Burn Wounds and Skin Graft Donor Sites - An Institutional Review
title 96 Poly-dl-lactide Copolymer-dressing Use on Burn Wounds and Skin Graft Donor Sites - An Institutional Review
title_full 96 Poly-dl-lactide Copolymer-dressing Use on Burn Wounds and Skin Graft Donor Sites - An Institutional Review
title_fullStr 96 Poly-dl-lactide Copolymer-dressing Use on Burn Wounds and Skin Graft Donor Sites - An Institutional Review
title_full_unstemmed 96 Poly-dl-lactide Copolymer-dressing Use on Burn Wounds and Skin Graft Donor Sites - An Institutional Review
title_short 96 Poly-dl-lactide Copolymer-dressing Use on Burn Wounds and Skin Graft Donor Sites - An Institutional Review
title_sort 96 poly-dl-lactide copolymer-dressing use on burn wounds and skin graft donor sites - an institutional review
topic Correlative XII: Clinical Sciences Wounds & Scars 2
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8945437/
http://dx.doi.org/10.1093/jbcr/irac012.098
work_keys_str_mv AT lagzieltomer 96polydllactidecopolymerdressinguseonburnwoundsandskingraftdonorsitesaninstitutionalreview
AT metoyergaryn 96polydllactidecopolymerdressinguseonburnwoundsandskingraftdonorsitesaninstitutionalreview
AT kawajiqingwen 96polydllactidecopolymerdressinguseonburnwoundsandskingraftdonorsitesaninstitutionalreview
AT akhavanaryaa 96polydllactidecopolymerdressinguseonburnwoundsandskingraftdonorsitesaninstitutionalreview
AT coxcarriea 96polydllactidecopolymerdressinguseonburnwoundsandskingraftdonorsitesaninstitutionalreview
AT caffreyjulie 96polydllactidecopolymerdressinguseonburnwoundsandskingraftdonorsitesaninstitutionalreview
AT hultmancharless 96polydllactidecopolymerdressinguseonburnwoundsandskingraftdonorsitesaninstitutionalreview
AT duraeselianaf 96polydllactidecopolymerdressinguseonburnwoundsandskingraftdonorsitesaninstitutionalreview