Cargando…

The Mechanisms of Restenosis and Relevance to Next Generation Stent Design

Stents are lifesaving mechanical devices that re-establish essential blood flow to the coronary circulation after significant vessel occlusion due to coronary vessel disease or thrombolytic blockade. Improvements in stent surface engineering over the last 20 years have seen significant reductions in...

Descripción completa

Detalles Bibliográficos
Autores principales: Clare, Jessie, Ganly, Justin, Bursill, Christina A., Sumer, Huseyin, Kingshott, Peter, de Haan, Judy B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8945897/
https://www.ncbi.nlm.nih.gov/pubmed/35327622
http://dx.doi.org/10.3390/biom12030430
_version_ 1784674063634923520
author Clare, Jessie
Ganly, Justin
Bursill, Christina A.
Sumer, Huseyin
Kingshott, Peter
de Haan, Judy B.
author_facet Clare, Jessie
Ganly, Justin
Bursill, Christina A.
Sumer, Huseyin
Kingshott, Peter
de Haan, Judy B.
author_sort Clare, Jessie
collection PubMed
description Stents are lifesaving mechanical devices that re-establish essential blood flow to the coronary circulation after significant vessel occlusion due to coronary vessel disease or thrombolytic blockade. Improvements in stent surface engineering over the last 20 years have seen significant reductions in complications arising due to restenosis and thrombosis. However, under certain conditions such as diabetes mellitus (DM), the incidence of stent-mediated complications remains 2–4-fold higher than seen in non-diabetic patients. The stents with the largest market share are designed to target the mechanisms behind neointimal hyperplasia (NIH) through anti-proliferative drugs that prevent the formation of a neointima by halting the cell cycle of vascular smooth muscle cells (VSMCs). Thrombosis is treated through dual anti-platelet therapy (DAPT), which is the continual use of aspirin and a P2Y(12) inhibitor for 6–12 months. While the most common stents currently in use are reasonably effective at treating these complications, there is still significant room for improvement. Recently, inflammation and redox stress have been identified as major contributing factors that increase the risk of stent-related complications following percutaneous coronary intervention (PCI). The aim of this review is to examine the mechanisms behind inflammation and redox stress through the lens of PCI and its complications and to establish whether tailored targeting of these key mechanistic pathways offers improved outcomes for patients, particularly those where stent placement remains vulnerable to complications. In summary, our review highlights the most recent and promising research being undertaken in understanding the mechanisms of redox biology and inflammation in the context of stent design. We emphasize the benefits of a targeted mechanistic approach to decrease all-cause mortality, even in patients with diabetes.
format Online
Article
Text
id pubmed-8945897
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-89458972022-03-25 The Mechanisms of Restenosis and Relevance to Next Generation Stent Design Clare, Jessie Ganly, Justin Bursill, Christina A. Sumer, Huseyin Kingshott, Peter de Haan, Judy B. Biomolecules Review Stents are lifesaving mechanical devices that re-establish essential blood flow to the coronary circulation after significant vessel occlusion due to coronary vessel disease or thrombolytic blockade. Improvements in stent surface engineering over the last 20 years have seen significant reductions in complications arising due to restenosis and thrombosis. However, under certain conditions such as diabetes mellitus (DM), the incidence of stent-mediated complications remains 2–4-fold higher than seen in non-diabetic patients. The stents with the largest market share are designed to target the mechanisms behind neointimal hyperplasia (NIH) through anti-proliferative drugs that prevent the formation of a neointima by halting the cell cycle of vascular smooth muscle cells (VSMCs). Thrombosis is treated through dual anti-platelet therapy (DAPT), which is the continual use of aspirin and a P2Y(12) inhibitor for 6–12 months. While the most common stents currently in use are reasonably effective at treating these complications, there is still significant room for improvement. Recently, inflammation and redox stress have been identified as major contributing factors that increase the risk of stent-related complications following percutaneous coronary intervention (PCI). The aim of this review is to examine the mechanisms behind inflammation and redox stress through the lens of PCI and its complications and to establish whether tailored targeting of these key mechanistic pathways offers improved outcomes for patients, particularly those where stent placement remains vulnerable to complications. In summary, our review highlights the most recent and promising research being undertaken in understanding the mechanisms of redox biology and inflammation in the context of stent design. We emphasize the benefits of a targeted mechanistic approach to decrease all-cause mortality, even in patients with diabetes. MDPI 2022-03-10 /pmc/articles/PMC8945897/ /pubmed/35327622 http://dx.doi.org/10.3390/biom12030430 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Review
Clare, Jessie
Ganly, Justin
Bursill, Christina A.
Sumer, Huseyin
Kingshott, Peter
de Haan, Judy B.
The Mechanisms of Restenosis and Relevance to Next Generation Stent Design
title The Mechanisms of Restenosis and Relevance to Next Generation Stent Design
title_full The Mechanisms of Restenosis and Relevance to Next Generation Stent Design
title_fullStr The Mechanisms of Restenosis and Relevance to Next Generation Stent Design
title_full_unstemmed The Mechanisms of Restenosis and Relevance to Next Generation Stent Design
title_short The Mechanisms of Restenosis and Relevance to Next Generation Stent Design
title_sort mechanisms of restenosis and relevance to next generation stent design
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8945897/
https://www.ncbi.nlm.nih.gov/pubmed/35327622
http://dx.doi.org/10.3390/biom12030430
work_keys_str_mv AT clarejessie themechanismsofrestenosisandrelevancetonextgenerationstentdesign
AT ganlyjustin themechanismsofrestenosisandrelevancetonextgenerationstentdesign
AT bursillchristinaa themechanismsofrestenosisandrelevancetonextgenerationstentdesign
AT sumerhuseyin themechanismsofrestenosisandrelevancetonextgenerationstentdesign
AT kingshottpeter themechanismsofrestenosisandrelevancetonextgenerationstentdesign
AT dehaanjudyb themechanismsofrestenosisandrelevancetonextgenerationstentdesign
AT clarejessie mechanismsofrestenosisandrelevancetonextgenerationstentdesign
AT ganlyjustin mechanismsofrestenosisandrelevancetonextgenerationstentdesign
AT bursillchristinaa mechanismsofrestenosisandrelevancetonextgenerationstentdesign
AT sumerhuseyin mechanismsofrestenosisandrelevancetonextgenerationstentdesign
AT kingshottpeter mechanismsofrestenosisandrelevancetonextgenerationstentdesign
AT dehaanjudyb mechanismsofrestenosisandrelevancetonextgenerationstentdesign