Cargando…
533 Human Case Characterizations of Skin Burn Using Novel Multi-Spectral Short Wave Infrared Imaging
INTRODUCTION: Determining the depth of skin burns in patients is critical for surgical decision making, but currently lacks accuracy in clinical practice. Short-wave infrared (SWIR) light penetrates tissue more than visual or near-infrared light and is very sensitive to water content. We have shown...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8946290/ http://dx.doi.org/10.1093/jbcr/irac012.162 |
_version_ | 1784674160845258752 |
---|---|
author | Nunez, Johanna H Park, Caroline Clark, Audra Akarichi, Chiaka Arnoldo, Brett Mandell, Samuel P Carlson, Deborah L Huebinger, Ryan M Chan, Rodney K Goverman, Jeremy Mironov, Sergey Levi, Benjamin Berenfeld, Omer |
author_facet | Nunez, Johanna H Park, Caroline Clark, Audra Akarichi, Chiaka Arnoldo, Brett Mandell, Samuel P Carlson, Deborah L Huebinger, Ryan M Chan, Rodney K Goverman, Jeremy Mironov, Sergey Levi, Benjamin Berenfeld, Omer |
author_sort | Nunez, Johanna H |
collection | PubMed |
description | INTRODUCTION: Determining the depth of skin burns in patients is critical for surgical decision making, but currently lacks accuracy in clinical practice. Short-wave infrared (SWIR) light penetrates tissue more than visual or near-infrared light and is very sensitive to water content. We have shown in animal models that imaging of skin burns in the SWIR range distinguishes between superficial and deep tissue necrosis. Here we present the first 2 cases of multi-spectral SWIR imaging of human burn injury as a first step toward a non-invasive, label-free, technique for burn depth determination. METHODS: Two subjects admitted for mixed depth, thermal, 6% and 7% total body surface area (TBSA), burns were studied. Prior to burn excision, a novel system, based on a specialized camera, imaged the burn areas and normal skin at 4 different SWIR bands. Standard photographs from imaged areas were collected and presented for 5 independent, blinded, surgeons’ assessments. In SWIR images, 3-5 regions of interest (ROIs) were selected in burned and adjacent normal skin and the reflected light intensity in each ROI was averaged. RESULTS: Visual and SWIR images were collected for 9 burn areas in the hands, arms, and shoulder of 2 patients (Panel A). Fifty ROIs from the burn areas were assessed by the surgeons and 30 (60%) ROIs were agreed as being superficial or superficial partial thickness (n=5), deep partial thickness (n=11), or full thickness (n=14) burns by a majority (60% or above consensus together with a possible disagreement only between deep partial and full thickness burn). In Panel B the cumulative SWIR reflectance intensity at the 4 SWIR bands for the 3 burn groups, determined by expert surgeon evaluation, and normal skin are compared. The reflectance from superficial and superficial partial thickness burns (yellow) were 102.7±1.2%, 102.3±0.7% and 103.4±1.4% of the normal skin reflectance for 1200, 1650 and 1940 nm, respectively. On the other hand, the reflectance from deep partial thickness burns (grey) were 96.7±0.1% and 94.7±0.1%, and for full thickness burn (red) were 96.1±1.4% and 93.7±1.6% of normal skin reflectance for 1650 and 1940 nm, respectively. CONCLUSIONS: We present the first human SWIR study demonstrating a distinct reflectance intensity of SWIR wavelengths for different burn depths based on surgeon assessments. The results motivate further studies of SWIR imaging of burns in the hope to non-invasively and accurately identify operative versus non-operative burns. |
format | Online Article Text |
id | pubmed-8946290 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-89462902022-03-28 533 Human Case Characterizations of Skin Burn Using Novel Multi-Spectral Short Wave Infrared Imaging Nunez, Johanna H Park, Caroline Clark, Audra Akarichi, Chiaka Arnoldo, Brett Mandell, Samuel P Carlson, Deborah L Huebinger, Ryan M Chan, Rodney K Goverman, Jeremy Mironov, Sergey Levi, Benjamin Berenfeld, Omer J Burn Care Res Clinical Sciences: Wounds & Scars 1 INTRODUCTION: Determining the depth of skin burns in patients is critical for surgical decision making, but currently lacks accuracy in clinical practice. Short-wave infrared (SWIR) light penetrates tissue more than visual or near-infrared light and is very sensitive to water content. We have shown in animal models that imaging of skin burns in the SWIR range distinguishes between superficial and deep tissue necrosis. Here we present the first 2 cases of multi-spectral SWIR imaging of human burn injury as a first step toward a non-invasive, label-free, technique for burn depth determination. METHODS: Two subjects admitted for mixed depth, thermal, 6% and 7% total body surface area (TBSA), burns were studied. Prior to burn excision, a novel system, based on a specialized camera, imaged the burn areas and normal skin at 4 different SWIR bands. Standard photographs from imaged areas were collected and presented for 5 independent, blinded, surgeons’ assessments. In SWIR images, 3-5 regions of interest (ROIs) were selected in burned and adjacent normal skin and the reflected light intensity in each ROI was averaged. RESULTS: Visual and SWIR images were collected for 9 burn areas in the hands, arms, and shoulder of 2 patients (Panel A). Fifty ROIs from the burn areas were assessed by the surgeons and 30 (60%) ROIs were agreed as being superficial or superficial partial thickness (n=5), deep partial thickness (n=11), or full thickness (n=14) burns by a majority (60% or above consensus together with a possible disagreement only between deep partial and full thickness burn). In Panel B the cumulative SWIR reflectance intensity at the 4 SWIR bands for the 3 burn groups, determined by expert surgeon evaluation, and normal skin are compared. The reflectance from superficial and superficial partial thickness burns (yellow) were 102.7±1.2%, 102.3±0.7% and 103.4±1.4% of the normal skin reflectance for 1200, 1650 and 1940 nm, respectively. On the other hand, the reflectance from deep partial thickness burns (grey) were 96.7±0.1% and 94.7±0.1%, and for full thickness burn (red) were 96.1±1.4% and 93.7±1.6% of normal skin reflectance for 1650 and 1940 nm, respectively. CONCLUSIONS: We present the first human SWIR study demonstrating a distinct reflectance intensity of SWIR wavelengths for different burn depths based on surgeon assessments. The results motivate further studies of SWIR imaging of burns in the hope to non-invasively and accurately identify operative versus non-operative burns. Oxford University Press 2022-03-23 /pmc/articles/PMC8946290/ http://dx.doi.org/10.1093/jbcr/irac012.162 Text en © The Author(s) 2022. Published by Oxford University Press on behalf of the American Burn Association. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Clinical Sciences: Wounds & Scars 1 Nunez, Johanna H Park, Caroline Clark, Audra Akarichi, Chiaka Arnoldo, Brett Mandell, Samuel P Carlson, Deborah L Huebinger, Ryan M Chan, Rodney K Goverman, Jeremy Mironov, Sergey Levi, Benjamin Berenfeld, Omer 533 Human Case Characterizations of Skin Burn Using Novel Multi-Spectral Short Wave Infrared Imaging |
title | 533 Human Case Characterizations of Skin Burn Using Novel Multi-Spectral Short Wave Infrared Imaging |
title_full | 533 Human Case Characterizations of Skin Burn Using Novel Multi-Spectral Short Wave Infrared Imaging |
title_fullStr | 533 Human Case Characterizations of Skin Burn Using Novel Multi-Spectral Short Wave Infrared Imaging |
title_full_unstemmed | 533 Human Case Characterizations of Skin Burn Using Novel Multi-Spectral Short Wave Infrared Imaging |
title_short | 533 Human Case Characterizations of Skin Burn Using Novel Multi-Spectral Short Wave Infrared Imaging |
title_sort | 533 human case characterizations of skin burn using novel multi-spectral short wave infrared imaging |
topic | Clinical Sciences: Wounds & Scars 1 |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8946290/ http://dx.doi.org/10.1093/jbcr/irac012.162 |
work_keys_str_mv | AT nunezjohannah 533humancasecharacterizationsofskinburnusingnovelmultispectralshortwaveinfraredimaging AT parkcaroline 533humancasecharacterizationsofskinburnusingnovelmultispectralshortwaveinfraredimaging AT clarkaudra 533humancasecharacterizationsofskinburnusingnovelmultispectralshortwaveinfraredimaging AT akarichichiaka 533humancasecharacterizationsofskinburnusingnovelmultispectralshortwaveinfraredimaging AT arnoldobrett 533humancasecharacterizationsofskinburnusingnovelmultispectralshortwaveinfraredimaging AT mandellsamuelp 533humancasecharacterizationsofskinburnusingnovelmultispectralshortwaveinfraredimaging AT carlsondeborahl 533humancasecharacterizationsofskinburnusingnovelmultispectralshortwaveinfraredimaging AT huebingerryanm 533humancasecharacterizationsofskinburnusingnovelmultispectralshortwaveinfraredimaging AT chanrodneyk 533humancasecharacterizationsofskinburnusingnovelmultispectralshortwaveinfraredimaging AT govermanjeremy 533humancasecharacterizationsofskinburnusingnovelmultispectralshortwaveinfraredimaging AT mironovsergey 533humancasecharacterizationsofskinburnusingnovelmultispectralshortwaveinfraredimaging AT levibenjamin 533humancasecharacterizationsofskinburnusingnovelmultispectralshortwaveinfraredimaging AT berenfeldomer 533humancasecharacterizationsofskinburnusingnovelmultispectralshortwaveinfraredimaging |